File Download

There are no files associated with this item.

Supplementary

Conference Paper: A 4-Channel Optical Link Transmission for RF Coil Array at 1.5T

TitleA 4-Channel Optical Link Transmission for RF Coil Array at 1.5T
Authors
Issue Date2007
PublisherInternational Society for Magnetic Resonance in Medicine
Citation
Joint Annual Meeting ISMRM-ESMRMB SMRT16th Annual Meeting, Berlin, Germany, 19-25 May 2007, Abstract no. 1036 How to Cite?
AbstractLarge number of cables on RF array could produce serious electromagnetic interference, therefore, deteriorate the MR image quality. A 4-channel direct modulated optical fiber link has been designed and implemented to avoid these problems. The link performances are measured by bench tests. The optical link is used for a 4-channel neck coil array at 1.5T GE Signa MRI. The phantom and clinical images are successfully obtained by the optical link and compared to those by traditional coaxial cables. The SNR of the 4-channel phantom image using the optical link is 9% better than that using the original coaxial cables.
Persistent Identifierhttp://hdl.handle.net/10722/99638

 

DC FieldValueLanguage
dc.contributor.authorYuan, Jen_HK
dc.contributor.authorWei, Jen_HK
dc.contributor.authorCai, Gen_HK
dc.contributor.authorPang, Yen_HK
dc.contributor.authorDu, Cen_HK
dc.contributor.authorShen, GGen_HK
dc.date.accessioned2010-09-25T18:38:25Z-
dc.date.available2010-09-25T18:38:25Z-
dc.date.issued2007en_HK
dc.identifier.citationJoint Annual Meeting ISMRM-ESMRMB SMRT16th Annual Meeting, Berlin, Germany, 19-25 May 2007, Abstract no. 1036en_HK
dc.identifier.urihttp://hdl.handle.net/10722/99638-
dc.description.abstractLarge number of cables on RF array could produce serious electromagnetic interference, therefore, deteriorate the MR image quality. A 4-channel direct modulated optical fiber link has been designed and implemented to avoid these problems. The link performances are measured by bench tests. The optical link is used for a 4-channel neck coil array at 1.5T GE Signa MRI. The phantom and clinical images are successfully obtained by the optical link and compared to those by traditional coaxial cables. The SNR of the 4-channel phantom image using the optical link is 9% better than that using the original coaxial cables.-
dc.languageengen_HK
dc.publisherInternational Society for Magnetic Resonance in Medicine-
dc.relation.ispartofJoint Annual Meeting ISMRM-ESMRMB SMRTen_HK
dc.titleA 4-Channel Optical Link Transmission for RF Coil Array at 1.5Ten_HK