File Download

There are no files associated with this item.

Supplementary

Conference Paper: Jointly Denoise Diffusion-weighted Images Using a Weighted Nuclear Norm Minimization Approach

TitleJointly Denoise Diffusion-weighted Images Using a Weighted Nuclear Norm Minimization Approach
Authors
Issue Date2021
PublisherInternational Society of Magnetic Resonance Imaging (ISMRM) .
Citation
Proceedings of the 29th Annual Meeting & Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM), Virtual Conference, Vancouver, BC, Canada, 15-20 May 2021, paper no. 1334 How to Cite?
AbstractDiffusion MRI intrinsically suffers from low signal-to-noise ratio (SNR), especially when spatial resolution or b-value is high. A typical diffusion MRI scanning session produces image sets with same geometries but different diffusion directions and b-values, thus these diffusion-weighted (DW) images often share strong structural similarities. In this study, we developed a joint denoising method for DW images based on low-rank matrix approximation. This denoising method exploits structural similarities of DW image set. Both simulation and in vivo brain experiments demonstrate significant noise reduction in all DW images, revealing more microstructural details in quantitative diffusion maps.
DescriptionDigital Posters Session D-140: Diffusion Acquisition & Post-Processing - no. 1334
Persistent Identifierhttp://hdl.handle.net/10722/304066

 

DC FieldValueLanguage
dc.contributor.authorZhao, Y-
dc.contributor.authorXiao, L-
dc.contributor.authorZhang, Z-
dc.contributor.authorLiu, Y-
dc.contributor.authorGuo, H-
dc.contributor.authorWu, EX-
dc.date.accessioned2021-09-23T08:54:46Z-
dc.date.available2021-09-23T08:54:46Z-
dc.date.issued2021-
dc.identifier.citationProceedings of the 29th Annual Meeting & Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM), Virtual Conference, Vancouver, BC, Canada, 15-20 May 2021, paper no. 1334-
dc.identifier.urihttp://hdl.handle.net/10722/304066-
dc.descriptionDigital Posters Session D-140: Diffusion Acquisition & Post-Processing - no. 1334-
dc.description.abstractDiffusion MRI intrinsically suffers from low signal-to-noise ratio (SNR), especially when spatial resolution or b-value is high. A typical diffusion MRI scanning session produces image sets with same geometries but different diffusion directions and b-values, thus these diffusion-weighted (DW) images often share strong structural similarities. In this study, we developed a joint denoising method for DW images based on low-rank matrix approximation. This denoising method exploits structural similarities of DW image set. Both simulation and in vivo brain experiments demonstrate significant noise reduction in all DW images, revealing more microstructural details in quantitative diffusion maps.-
dc.languageeng-
dc.publisherInternational Society of Magnetic Resonance Imaging (ISMRM) .-
dc.relation.ispartofISMRM (International Society of Magnetic Resonance Imaging) Virtual Conference & Exhibition, 2021-
dc.titleJointly Denoise Diffusion-weighted Images Using a Weighted Nuclear Norm Minimization Approach-
dc.typeConference_Paper-
dc.identifier.emailWu, EX: ewu@eee.hku.hk-
dc.identifier.authorityWu, EX=rp00193-
dc.identifier.hkuros325457-
dc.identifier.spage1334-
dc.identifier.epage1334-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats