Conference Paper: Improved Parallel Imaging Reconstruction of EPI using Inversely Distortion Corrected FLASH as Calibration Data

TitleImproved Parallel Imaging Reconstruction of EPI using Inversely Distortion Corrected FLASH as Calibration Data
Authors
Issue Date2018
PublisherInternational Society for Magnetic Resonance in Medicine.
Citation
Proceedings of International Society for Magnetic Resonance in Medicine & The European Society for Magnetic Resonance in Medicine and Biology (ISMRM-ESMRMB) Joint Annual Meeting, Paris, France, 16-21 June 2018, abstract no. 3509 How to Cite?
AbstractFor parallel imaging reconstruction of EPI, EPI based calibration scan may suffer from ghost artifacts, whereas non-EPI based calibration scan such as FLASH cannot provide consistent geometric distortion. In this study, we propose to employ dual-echo FLASH as the calibration scan, such that B0 field maps can be derived to match FLASH images to EPI images and the reconstruction artifact related to inconsistent distortion can be minimized.
Descriptione-Poster Session: Acquisition, Reconstruction & Analysis - Image Reconstruction Potpourri - Abstract #3509
Persistent Identifierhttp://hdl.handle.net/10722/261187

 

DC FieldValueLanguage
dc.contributor.authorLYU, M-
dc.contributor.authorLIU, Y-
dc.contributor.authorWu, EX-
dc.date.accessioned2018-09-14T08:53:56Z-
dc.date.available2018-09-14T08:53:56Z-
dc.date.issued2018-
dc.identifier.citationProceedings of International Society for Magnetic Resonance in Medicine & The European Society for Magnetic Resonance in Medicine and Biology (ISMRM-ESMRMB) Joint Annual Meeting, Paris, France, 16-21 June 2018, abstract no. 3509-
dc.identifier.urihttp://hdl.handle.net/10722/261187-
dc.descriptione-Poster Session: Acquisition, Reconstruction & Analysis - Image Reconstruction Potpourri - Abstract #3509-
dc.description.abstractFor parallel imaging reconstruction of EPI, EPI based calibration scan may suffer from ghost artifacts, whereas non-EPI based calibration scan such as FLASH cannot provide consistent geometric distortion. In this study, we propose to employ dual-echo FLASH as the calibration scan, such that B0 field maps can be derived to match FLASH images to EPI images and the reconstruction artifact related to inconsistent distortion can be minimized.-
dc.languageeng-
dc.publisherInternational Society for Magnetic Resonance in Medicine.-
dc.relation.ispartofISMRM-ESMRMB Joint Annual Meeting 2018-
dc.titleImproved Parallel Imaging Reconstruction of EPI using Inversely Distortion Corrected FLASH as Calibration Data-
dc.typeConference_Paper-