File Download

There are no files associated with this item.

Supplementary

Conference Paper: Multi-Shot Diffusion-Weighted EPI Reconstruction Based on Locally Low-Rank Constraints

TitleMulti-Shot Diffusion-Weighted EPI Reconstruction Based on Locally Low-Rank Constraints
Authors
Issue Date2018
PublisherInternational Society for Magnetic Resonance in Medicine.
Citation
Proceedings of International Society for Magnetic Resonance in Medicine & The European Society for Magnetic Resonance in Medicine and Biology (ISMRM-ESMRMB) Joint Annual Meeting, Paris, France, 16-21 June 2018, abstract no, 5332 How to Cite?
AbstractBased on the locally low rank (LLR) property of multi-shot diffusion-weighted imaging (DWI), a novel reconstruction scheme is proposed to achieve high signal-to-noise ratio (SNR) without explicit estimation of inter-shot phase variation. The results from in vivo DWI data indicate that the proposed method can effectively improve the image quality at various shot numbers when compared with traditional shot-by-shot reconstruction approaches.
Descriptione-Poster Session: Diffusion MRI: Acquisition & Reconstruction - Abstract #5332
Persistent Identifierhttp://hdl.handle.net/10722/261185

 

DC FieldValueLanguage
dc.contributor.authorMA, X-
dc.contributor.authorLYU, M-
dc.contributor.authorLiu, Y-
dc.contributor.authorWu, EX-
dc.date.accessioned2018-09-14T08:53:54Z-
dc.date.available2018-09-14T08:53:54Z-
dc.date.issued2018-
dc.identifier.citationProceedings of International Society for Magnetic Resonance in Medicine & The European Society for Magnetic Resonance in Medicine and Biology (ISMRM-ESMRMB) Joint Annual Meeting, Paris, France, 16-21 June 2018, abstract no, 5332-
dc.identifier.urihttp://hdl.handle.net/10722/261185-
dc.descriptione-Poster Session: Diffusion MRI: Acquisition & Reconstruction - Abstract #5332-
dc.description.abstractBased on the locally low rank (LLR) property of multi-shot diffusion-weighted imaging (DWI), a novel reconstruction scheme is proposed to achieve high signal-to-noise ratio (SNR) without explicit estimation of inter-shot phase variation. The results from in vivo DWI data indicate that the proposed method can effectively improve the image quality at various shot numbers when compared with traditional shot-by-shot reconstruction approaches.-
dc.languageeng-
dc.publisherInternational Society for Magnetic Resonance in Medicine.-
dc.relation.ispartofISMRM-ESMRMB Joint Annual Meeting 2018-
dc.titleMulti-Shot Diffusion-Weighted EPI Reconstruction Based on Locally Low-Rank Constraints-
dc.typeConference_Paper-
dc.identifier.emailWu, EX: ewu@eee.hku.hk-
dc.identifier.authorityWu, EX=rp00193-
dc.identifier.hkuros291508-
dc.identifier.spageabstract no, 5332-
dc.identifier.epageabstract no, 5332-
dc.publisher.placeUnited States-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats