Title | Dual-comb optical coherence tomography |
---|---|
Authors | |
Issue Date | 2018 |
Publisher | Optical Society of America. |
Citation | Proceedings OSA Advanced Photonics Congress 2018 (BGPP, IPR, NP, NOMA, Sensors, Networks, SPPCom, SOF), Zurich, Switzerland, 2–5 July 2018. In OSA Technical Digest (online), 2018, paper no. SeTu3H.2 How to Cite? |
Abstract | An optical coherence tomography (OCT) system that leverages a dual-comb source based on electro-optic modulators and fiber nonlinear devices is demonstrated. The comb sources generate 270-fs pulses and the system achieves over 9-mm imaging depth. |
Description | Optical Sensors - Frequency Comb Sensors (SeTu3H) Session - paper no. SeTu3H.2 |
Persistent Identifier | http://hdl.handle.net/10722/260698 |
ISBN |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kang, J | - |
dc.contributor.author | Feng, P | - |
dc.contributor.author | Li, B | - |
dc.contributor.author | Wong, KKY | - |
dc.date.accessioned | 2018-09-14T08:45:53Z | - |
dc.date.available | 2018-09-14T08:45:53Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | Proceedings OSA Advanced Photonics Congress 2018 (BGPP, IPR, NP, NOMA, Sensors, Networks, SPPCom, SOF), Zurich, Switzerland, 2–5 July 2018. In OSA Technical Digest (online), 2018, paper no. SeTu3H.2 | - |
dc.identifier.isbn | 978-1-943580-43-9 | - |
dc.identifier.uri | http://hdl.handle.net/10722/260698 | - |
dc.description | Optical Sensors - Frequency Comb Sensors (SeTu3H) Session - paper no. SeTu3H.2 | - |
dc.description.abstract | An optical coherence tomography (OCT) system that leverages a dual-comb source based on electro-optic modulators and fiber nonlinear devices is demonstrated. The comb sources generate 270-fs pulses and the system achieves over 9-mm imaging depth. | - |
dc.language | eng | - |
dc.publisher | Optical Society of America. | - |
dc.relation.ispartof | OSA Technical Digest | - |
dc.title | Dual-comb optical coherence tomography | - |
dc.type | Conference_Paper | - |
dc.identifier.email | Wong, KKY: kywong@eee.hku.hk | - |
dc.identifier.authority | Wong, KKY=rp00189 | - |
dc.identifier.doi | 10.1364/SENSORS.2018.SeTu3H.2 | - |
dc.identifier.scopus | eid_2-s2.0-85051265033 | - |
dc.identifier.hkuros | 290447 | - |
dc.identifier.spage | paper no. SeTu3H.2 | - |
dc.identifier.epage | paper no. SeTu3H.2 | - |
dc.publisher.place | United States | - |