File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)

Conference Paper: Ultrafast imaging using combined transmissions with coherence-based reconstruction

TitleUltrafast imaging using combined transmissions with coherence-based reconstruction
Authors
KeywordsCoherence-based reconstruction
Combined transmissions
Ultrafast imaging
Issue Date2016
PublisherIEEE. The Journal's web site is located at http://www.ieeexplore.ieee.org/xpl/conhome.jsp?punumber=1000770
Citation
The 2016 IEEE International Ultrasonics Symposium (IUS 2016), Tours, France, 18-21 September 2016. In Conference Proceedings, 2016, p. 1-4 How to Cite?
AbstractUltrafast plane wave (PW) imaging and synthetic aperture (SA) imaging have become the prevalent techniques for non-conventional medical ultrasound imaging. In both imaging techniques, the image contrast is generally compromised by reducing the number of transmissions for high frame rate. Moreover, the axial ghost artifact in PW imaging has been demonstrated attributed to the edge array elements. We hereby propose a new methodology that achieves high contrast and reduces the axial ghost artifact with only three transmissions for ultrafast imaging. A new coherence-based factor was derived. The raw data from the PW and the spherical wave (SW) transmissions were compounded based on the factor, with the consideration of their respective coherence and interrelationship, to suppress the side lobes and reduce the axial artifact. Field II simulations show that our proposed method greatly reduced the axial artifact by 20 dB ∼ 35 dB compared with coherent plane wave compounding (CPW) and suppressed side lobes by 15 dB ∼ 30 dB compared with CPW and sparse SA imaging. © 2016 IEEE.
Persistent Identifierhttp://hdl.handle.net/10722/238467
ISBN
ISSN

 

DC FieldValueLanguage
dc.contributor.authorZhang, Y-
dc.contributor.authorGuo, Y-
dc.contributor.authorLee, W-
dc.date.accessioned2017-02-15T01:04:24Z-
dc.date.available2017-02-15T01:04:24Z-
dc.date.issued2016-
dc.identifier.citationThe 2016 IEEE International Ultrasonics Symposium (IUS 2016), Tours, France, 18-21 September 2016. In Conference Proceedings, 2016, p. 1-4-
dc.identifier.isbn978-146739897-8-
dc.identifier.issn1051-0117-
dc.identifier.urihttp://hdl.handle.net/10722/238467-
dc.description.abstractUltrafast plane wave (PW) imaging and synthetic aperture (SA) imaging have become the prevalent techniques for non-conventional medical ultrasound imaging. In both imaging techniques, the image contrast is generally compromised by reducing the number of transmissions for high frame rate. Moreover, the axial ghost artifact in PW imaging has been demonstrated attributed to the edge array elements. We hereby propose a new methodology that achieves high contrast and reduces the axial ghost artifact with only three transmissions for ultrafast imaging. A new coherence-based factor was derived. The raw data from the PW and the spherical wave (SW) transmissions were compounded based on the factor, with the consideration of their respective coherence and interrelationship, to suppress the side lobes and reduce the axial artifact. Field II simulations show that our proposed method greatly reduced the axial artifact by 20 dB ∼ 35 dB compared with coherent plane wave compounding (CPW) and suppressed side lobes by 15 dB ∼ 30 dB compared with CPW and sparse SA imaging. © 2016 IEEE.-
dc.languageeng-
dc.publisherIEEE. The Journal's web site is located at http://www.ieeexplore.ieee.org/xpl/conhome.jsp?punumber=1000770-
dc.relation.ispartofIEEE International Ultrasonics Symposium Proceedings-
dc.rightsIEEE International Ultrasonics Symposium Proceedings. Copyright © IEEE.-
dc.rights©2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.-
dc.subjectCoherence-based reconstruction-
dc.subjectCombined transmissions-
dc.subjectUltrafast imaging-
dc.titleUltrafast imaging using combined transmissions with coherence-based reconstruction-
dc.typeConference_Paper-
dc.identifier.emailLee, W: wnlee@eee.hku.hk-
dc.identifier.authorityLee, W=rp01663-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1109/ULTSYM.2016.7728800-
dc.identifier.scopuseid_2-s2.0-84996479872-
dc.identifier.hkuros271163-
dc.identifier.spage1-
dc.identifier.epage4-
dc.publisher.placeUnited States-
dc.customcontrol.immutablesml 170215-
dc.identifier.issnl1051-0117-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats