Conference Paper: Simultaneous spin echo and gradient echo imaging with controlled aliasing and parallel imaging reconstruction
Title | Simultaneous spin echo and gradient echo imaging with controlled aliasing and parallel imaging reconstruction |
---|---|
Authors | |
Issue Date | 2016 |
Citation | The 24th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2016), Singapore, 7-13 May 2016. How to Cite? |
Abstract | We propose a method to simultaneously acquire spin echo and gradient echo and form two images with distinct contrasts. The spin echo and gradient echo are created by phase-cycled RF pulses, so that they are shifted from each other in image space. In reconstruction, coil sensitivity information can be used to separate them. This study demonstrates the feasibility of extracting multiple echo components using controlled aliasing and parallel imaging reconstruction. |
Description | Electronic Poster Session: Acquisition, Reconstruction & Analysis 2 - Contrast Mechanisms & Artefacts: System Imperfections & Implants: no. 4294 |
Persistent Identifier | http://hdl.handle.net/10722/234989 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lyu, M | - |
dc.contributor.author | Xie, VB | - |
dc.contributor.author | Gao, P | - |
dc.contributor.author | Hui, ESK | - |
dc.contributor.author | Wu, EX | - |
dc.date.accessioned | 2016-10-14T13:50:33Z | - |
dc.date.available | 2016-10-14T13:50:33Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | The 24th Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2016), Singapore, 7-13 May 2016. | - |
dc.identifier.uri | http://hdl.handle.net/10722/234989 | - |
dc.description | Electronic Poster Session: Acquisition, Reconstruction & Analysis 2 - Contrast Mechanisms & Artefacts: System Imperfections & Implants: no. 4294 | - |
dc.description.abstract | We propose a method to simultaneously acquire spin echo and gradient echo and form two images with distinct contrasts. The spin echo and gradient echo are created by phase-cycled RF pulses, so that they are shifted from each other in image space. In reconstruction, coil sensitivity information can be used to separate them. This study demonstrates the feasibility of extracting multiple echo components using controlled aliasing and parallel imaging reconstruction. | - |
dc.language | eng | - |
dc.relation.ispartof | ISMRM 24th Annual Meeting | - |
dc.title | Simultaneous spin echo and gradient echo imaging with controlled aliasing and parallel imaging reconstruction | - |