Conference Paper: Optimal phasor data concentrator installation for traffic reduction in smart grid wide-area monitoring systems
Title | Optimal phasor data concentrator installation for traffic reduction in smart grid wide-area monitoring systems |
---|---|
Authors | |
Issue Date | 2013 |
Publisher | IEEE. The Journal's web site is located at http://www.ieeexplore.ieee.org/xpl/conhome.jsp?punumber=1000308 |
Citation | The 2013 IEEE Global Communications Conference (GLOBECOM 2013), Atlanta, GA., USA, 9-13 December 2013. In Globecom. IEEE Conference and Exhibition, 2013, p. 2622-2627 How to Cite? |
Abstract | As one of the core components in wide-area monitoring systems (WAMS), phasor measurement units (PMUs) acquire highly accurate and time-synchronized phasor data at high frequency for smart grid monitoring, protection, and control. Despite the advantages of PMUs, they do generate much data and create a heavy burden on the communication network. One way of alleviating such burden is to install phasor data concentrators (PDC) across the power system to concentrate data generated by the PMUs. Although PDCs are expensive as well, this may still be a much cheaper and more practical option than building a high bandwidth network for WAMS. Therefore, it is very important to solve the optimal PDC installation problem so as to achieve a desired level of traffic reduction. This paper is the first to address this problem and we give solutions for the IEEE 14-bus, 30-bus, and 57-bus systems. |
Description | Conference Theme: the Power of Global Communications Symposium on Selected Areas in Communications |
Persistent Identifier | http://hdl.handle.net/10722/191601 |
ISBN | |
ISSN | |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wen, MHF | en_US |
dc.contributor.author | Li, VOK | en_US |
dc.date.accessioned | 2013-10-15T07:14:33Z | - |
dc.date.available | 2013-10-15T07:14:33Z | - |
dc.date.issued | 2013 | en_US |
dc.identifier.citation | The 2013 IEEE Global Communications Conference (GLOBECOM 2013), Atlanta, GA., USA, 9-13 December 2013. In Globecom. IEEE Conference and Exhibition, 2013, p. 2622-2627 | en_US |
dc.identifier.isbn | 9781479913534 | - |
dc.identifier.issn | 1930-529X | - |
dc.identifier.uri | http://hdl.handle.net/10722/191601 | - |
dc.description | Conference Theme: the Power of Global Communications | - |
dc.description | Symposium on Selected Areas in Communications | - |
dc.description.abstract | As one of the core components in wide-area monitoring systems (WAMS), phasor measurement units (PMUs) acquire highly accurate and time-synchronized phasor data at high frequency for smart grid monitoring, protection, and control. Despite the advantages of PMUs, they do generate much data and create a heavy burden on the communication network. One way of alleviating such burden is to install phasor data concentrators (PDC) across the power system to concentrate data generated by the PMUs. Although PDCs are expensive as well, this may still be a much cheaper and more practical option than building a high bandwidth network for WAMS. Therefore, it is very important to solve the optimal PDC installation problem so as to achieve a desired level of traffic reduction. This paper is the first to address this problem and we give solutions for the IEEE 14-bus, 30-bus, and 57-bus systems. | - |
dc.language | eng | en_US |
dc.publisher | IEEE. The Journal's web site is located at http://www.ieeexplore.ieee.org/xpl/conhome.jsp?punumber=1000308 | - |
dc.relation.ispartof | Globecom. IEEE Conference and Exhibition | en_US |
dc.title | Optimal phasor data concentrator installation for traffic reduction in smart grid wide-area monitoring systems | en_US |
dc.type | Conference_Paper | en_US |
dc.identifier.email | Wen, MHF: mileswen@eee.hku.hk | en_US |
dc.identifier.email | Li, VOK: vli@eee.hku.hk | - |
dc.identifier.authority | Li, VOK=rp00150 | en_US |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1109/GLOCOM.2013.6831470 | - |
dc.identifier.scopus | eid_2-s2.0-84904131525 | - |
dc.identifier.hkuros | 225440 | en_US |
dc.identifier.hkuros | 240517 | - |
dc.identifier.spage | 2622 | - |
dc.identifier.epage | 2627 | - |
dc.identifier.isi | WOS:000357299602116 | - |
dc.publisher.place | United States | - |
dc.customcontrol.immutable | sml 140630 | - |
dc.identifier.issnl | 1930-529X | - |