File Download
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1117/12.911131
- Scopus: eid_2-s2.0-84860251063
- WOS: WOS:000305070200079
- Find via
Supplementary
- Citations:
- Appears in Collections:
Conference Paper: Assessing 3D tunnel position in ACL reconstruction using a novel single image 3D-2D registration
Title | Assessing 3D tunnel position in ACL reconstruction using a novel single image 3D-2D registration |
---|---|
Authors | |
Keywords | 3D-2D registration Anterior cruciate ligament (ACL) Contour-based registration Expectation maximization ACL reconstruction |
Issue Date | 2012 |
Publisher | SPIE - International Society for Optical Engineering. |
Citation | SPIE Medical Imaging 2012, San Diego, CA., 4-9 February 2012. In Progress in Biomedical Optics and Imaging, 2012, v. 8316, article no. 831628 How to Cite? |
Abstract | The routinely used procedure for evaluating tunnel positions following anterior cruciate ligament (ACL) reconstructions based on standard X-ray images is known to pose difficulties in terms of obtaining accurate measures, especially in providing three-dimensional tunnel positions. This is largely due to the variability in individual knee joint pose relative to X-ray plates. Accurate results were reported using postoperative CT. However, its extensive usage in clinical routine is hampered by its major requirement of having CT scans of individual patients, which is not available for most ACL reconstructions. These difficulties are addressed through the proposed method, which aligns a knee model to X-ray images using our novel single-image 3D-2D registration method and then estimates the 3D tunnel position. In the proposed method, the alignment is achieved by using a novel contour-based 3D-2D registration method wherein image contours are treated as a set of oriented points. However, instead of using some form of orientation weighting function and multiplying it with a distance function, we formulate the 3D-2D registration as a probability density estimation using a mixture of von Mises-Fisher- Gaussian (vMFG) distributions and solve it through an expectation maximization (EM) algorithm. Compared with the ground-truth established from postoperative CT, our registration method in an experiment using a plastic phantom showed accurate results with errors of (-0.43°±1.19°, 0.45°±2.17°, 0.23°±1.05°) and (0.03±0.55, -0.03±0.54, -2.73±1.64) mm. As for the entry point of the ACL tunnel, one of the key measurements, it was obtained with high accuracy of 0.53±0.30 mm distance errors. © 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE). |
Description | Conference Theme: Image-Guided Procedures, Robotic Interventions, and Modeling Poster Session: 2D/3D and Fluoroscopy |
Persistent Identifier | http://hdl.handle.net/10722/158786 |
ISSN | 2023 SCImago Journal Rankings: 0.226 |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kang, X | en_US |
dc.contributor.author | Yau, WP | en_US |
dc.contributor.author | Otake, Y | en_US |
dc.contributor.author | Cheung, PYS | en_US |
dc.contributor.author | Hu, Y | en_US |
dc.contributor.author | Taylor, RH | en_US |
dc.date.accessioned | 2012-08-08T09:01:19Z | - |
dc.date.available | 2012-08-08T09:01:19Z | - |
dc.date.issued | 2012 | en_US |
dc.identifier.citation | SPIE Medical Imaging 2012, San Diego, CA., 4-9 February 2012. In Progress in Biomedical Optics and Imaging, 2012, v. 8316, article no. 831628 | en_US |
dc.identifier.issn | 1605-7422 | en_US |
dc.identifier.uri | http://hdl.handle.net/10722/158786 | - |
dc.description | Conference Theme: Image-Guided Procedures, Robotic Interventions, and Modeling | - |
dc.description | Poster Session: 2D/3D and Fluoroscopy | - |
dc.description.abstract | The routinely used procedure for evaluating tunnel positions following anterior cruciate ligament (ACL) reconstructions based on standard X-ray images is known to pose difficulties in terms of obtaining accurate measures, especially in providing three-dimensional tunnel positions. This is largely due to the variability in individual knee joint pose relative to X-ray plates. Accurate results were reported using postoperative CT. However, its extensive usage in clinical routine is hampered by its major requirement of having CT scans of individual patients, which is not available for most ACL reconstructions. These difficulties are addressed through the proposed method, which aligns a knee model to X-ray images using our novel single-image 3D-2D registration method and then estimates the 3D tunnel position. In the proposed method, the alignment is achieved by using a novel contour-based 3D-2D registration method wherein image contours are treated as a set of oriented points. However, instead of using some form of orientation weighting function and multiplying it with a distance function, we formulate the 3D-2D registration as a probability density estimation using a mixture of von Mises-Fisher- Gaussian (vMFG) distributions and solve it through an expectation maximization (EM) algorithm. Compared with the ground-truth established from postoperative CT, our registration method in an experiment using a plastic phantom showed accurate results with errors of (-0.43°±1.19°, 0.45°±2.17°, 0.23°±1.05°) and (0.03±0.55, -0.03±0.54, -2.73±1.64) mm. As for the entry point of the ACL tunnel, one of the key measurements, it was obtained with high accuracy of 0.53±0.30 mm distance errors. © 2012 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE). | en_US |
dc.language | eng | en_US |
dc.publisher | SPIE - International Society for Optical Engineering. | en_US |
dc.relation.ispartof | Progress in Biomedical Optics & Imaging: Proceedings of SPIE | en_US |
dc.rights | Copyright 2012 Society of Photo‑Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this publication for a fee or for commercial purposes, and modification of the contents of the publication are prohibited. This article is available online at https://doi.org/10.1117/12.911131 | - |
dc.subject | 3D-2D registration | en_US |
dc.subject | Anterior cruciate ligament (ACL) | en_US |
dc.subject | Contour-based registration | en_US |
dc.subject | Expectation maximization | en_US |
dc.subject | ACL reconstruction | - |
dc.title | Assessing 3D tunnel position in ACL reconstruction using a novel single image 3D-2D registration | en_US |
dc.type | Conference_Paper | en_US |
dc.identifier.email | Kang, X: h0794152@hku.hk | en_US |
dc.identifier.email | Yau, WP: peterwpy@hkucc.hku.hk | - |
dc.identifier.email | Cheung, PYS: paul.cheung@hku.hk | - |
dc.identifier.email | Hu, Y: yhud@hku.hk | - |
dc.identifier.authority | Yau, WP=rp00500 | en_US |
dc.description.nature | published_or_final_version | en_US |
dc.identifier.doi | 10.1117/12.911131 | en_US |
dc.identifier.scopus | eid_2-s2.0-84860251063 | en_US |
dc.identifier.hkuros | 208278 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-84860251063&selection=ref&src=s&origin=recordpage | en_US |
dc.identifier.volume | 8316 | en_US |
dc.identifier.isi | WOS:000305070200079 | - |
dc.publisher.place | United States | en_US |
dc.description.other | SPIE Medical Imaging 2012, San Diego, CA., 4-9 February 2012. In Progress in Biomedical Optics and Imaging, 2012, v. 8316, art. no. 831628 | - |
dc.identifier.scopusauthorid | Taylor, RH=7405756438 | en_US |
dc.identifier.scopusauthorid | Hu, Y=54935623100 | en_US |
dc.identifier.scopusauthorid | Cheung, PYS=7202595335 | en_US |
dc.identifier.scopusauthorid | Otake, Y=35771231600 | en_US |
dc.identifier.scopusauthorid | Yau, WP=55085455100 | en_US |
dc.identifier.scopusauthorid | Kang, X=36844160400 | en_US |
dc.customcontrol.immutable | sml 170329 amended | - |
dc.identifier.issnl | 1605-7422 | - |