Conference Paper: Matrix-pencil approach to blind separation of multi-channel bio-signals
| Title | Matrix-pencil approach to blind separation of multi-channel bio-signals |
|---|---|
| Authors | |
| Issue Date | 1999 |
| Citation | Annual International Conference Of The Ieee Engineering In Medicine And Biology - Proceedings, 1999, v. 2, p. 1008 How to Cite? |
| Abstract | Many biological and physiological processes can be modeled as a linear Multi-Input Multi-Output (MIMO) system. Blind deconvolution is ideal for retrieving the input signals and/or system parameters, given only the outputs and some input statistical information, but not the inputs themselves. In general biomedical signals sources have distinct, non-stationary, colored power spectral density, so, we use our algorithm developed before which works well for such kinds of signals. Simulation results are presented. |
| Persistent Identifier | http://hdl.handle.net/10722/158277 |
| ISSN | 2023 SCImago Journal Rankings: 0.340 |
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Xu, Weichao | en_HK |
| dc.contributor.author | Chang, Chunqi | en_HK |
| dc.contributor.author | Chan, Francis HY | en_HK |
| dc.date.accessioned | 2012-08-08T08:58:51Z | - |
| dc.date.available | 2012-08-08T08:58:51Z | - |
| dc.date.issued | 1999 | en_HK |
| dc.identifier.citation | Annual International Conference Of The Ieee Engineering In Medicine And Biology - Proceedings, 1999, v. 2, p. 1008 | en_US |
| dc.identifier.issn | 0589-1019 | en_HK |
| dc.identifier.uri | http://hdl.handle.net/10722/158277 | - |
| dc.description.abstract | Many biological and physiological processes can be modeled as a linear Multi-Input Multi-Output (MIMO) system. Blind deconvolution is ideal for retrieving the input signals and/or system parameters, given only the outputs and some input statistical information, but not the inputs themselves. In general biomedical signals sources have distinct, non-stationary, colored power spectral density, so, we use our algorithm developed before which works well for such kinds of signals. Simulation results are presented. | en_HK |
| dc.language | eng | en_US |
| dc.relation.ispartof | Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings | en_HK |
| dc.title | Matrix-pencil approach to blind separation of multi-channel bio-signals | en_HK |
| dc.type | Conference_Paper | en_HK |
| dc.identifier.email | Xu, Weichao: wcxu@eee.hku.hk | en_HK |
| dc.identifier.email | Chang, Chunqi: cqchang@eee.hku.hk | en_HK |
| dc.identifier.authority | Xu, Weichao=rp00198 | en_HK |
| dc.identifier.authority | Chang, Chunqi=rp00095 | en_HK |
| dc.description.nature | link_to_subscribed_fulltext | en_US |
| dc.identifier.scopus | eid_2-s2.0-0033354037 | en_HK |
| dc.identifier.volume | 2 | en_HK |
| dc.identifier.spage | 1008 | en_HK |
| dc.identifier.epage | 1008 | en_HK |
| dc.publisher.place | United States | en_HK |
| dc.identifier.scopusauthorid | Xu, Weichao=7404428876 | en_HK |
| dc.identifier.scopusauthorid | Chang, Chunqi=7407033052 | en_HK |
| dc.identifier.scopusauthorid | Chan, Francis HY=7202586429 | en_HK |
| dc.identifier.issnl | 0589-1019 | - |