File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: The effect of dentine location and tubule orientation on the bond strengths between resin and dentine

TitleThe effect of dentine location and tubule orientation on the bond strengths between resin and dentine
Authors
KeywordsChemicals And Cas Registry Numbers
Issue Date1999
PublisherElsevier Ltd. The Journal's web site is located at http://www.elsevier.com/locate/jdent
Citation
Journal Of Dentistry, 1999, v. 27 n. 4, p. 265-274 How to Cite?
AbstractThis study determined the influence of dentine structure on the micro-tensile bond strengths between resin and dentine of two different dentine adhesive systems (Single Bond, 3M Dental Products, St Paul, MN; MF-102 (experimental self-etching primer), GC Corporation, Tokyo, Japan). The study was separated into two main parts: bond strength measurement and investigation of the bonding interface. Twenty-two human premolars were used for the bond strength measurement. Each tooth was cut vertically, separating the tooth into mesio-distal halves. One half of the tooth was used to bond to a surface perpendicular to the dentinal tubules and other half to bond to a surface parallel to the tubules. For each half, six locations of dentine were bonded. Each material was used in accordance to the manufacturer's directions. Cylindrical hourglass-shaped specimens of 1.2 mm diameter at the bonded interface were manufactured. The bonds were stressed in tension at a crosshead speed of 1 mm/min. Mean bond strengths were compared using LSD, one-way ANOVA, and Student's t-test. The fractured surfaces were examined under a scanning electron microscope, and the frequency of fracture modes was compared using the Kruskal-Wallis and Mann-Whitney U tests. For the investigation of the bonded interface, four teeth were prepared by the same procedure used for the bond test specimens. The bonded interfaces were observed after an acid-base treatment or fracturing across the bonded interface, prior to investigation with a field-emission scanning electron microscope. For Single Bond, the bond strengths for mid-root dentine were significantly lower than for other locations (p < 0.05). For MF-102, there was no significant difference for all locations (p > 0.05). MF-102 bonded well to all locations of dentine while Single Bond showed a porous zone at the base of the hybrid layer. The bonds were not influenced by tubule orientation. The results indicate that the bond for Single Bond may be affected by its ability to penetrate demineralised dentine in different locations of a tooth. The self-etching primer of MF-102 produces a good bond and is independent of the position on the tooth. © 1999 Elsevier Science Ltd. All rights reserved.
Persistent Identifierhttp://hdl.handle.net/10722/90592
ISSN
2023 Impact Factor: 4.8
2023 SCImago Journal Rankings: 1.313
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorPhrukkanon, Sen_HK
dc.contributor.authorBurrow, MFen_HK
dc.contributor.authorTyas, MJen_HK
dc.date.accessioned2010-09-17T10:05:23Z-
dc.date.available2010-09-17T10:05:23Z-
dc.date.issued1999en_HK
dc.identifier.citationJournal Of Dentistry, 1999, v. 27 n. 4, p. 265-274en_HK
dc.identifier.issn0300-5712en_HK
dc.identifier.urihttp://hdl.handle.net/10722/90592-
dc.description.abstractThis study determined the influence of dentine structure on the micro-tensile bond strengths between resin and dentine of two different dentine adhesive systems (Single Bond, 3M Dental Products, St Paul, MN; MF-102 (experimental self-etching primer), GC Corporation, Tokyo, Japan). The study was separated into two main parts: bond strength measurement and investigation of the bonding interface. Twenty-two human premolars were used for the bond strength measurement. Each tooth was cut vertically, separating the tooth into mesio-distal halves. One half of the tooth was used to bond to a surface perpendicular to the dentinal tubules and other half to bond to a surface parallel to the tubules. For each half, six locations of dentine were bonded. Each material was used in accordance to the manufacturer's directions. Cylindrical hourglass-shaped specimens of 1.2 mm diameter at the bonded interface were manufactured. The bonds were stressed in tension at a crosshead speed of 1 mm/min. Mean bond strengths were compared using LSD, one-way ANOVA, and Student's t-test. The fractured surfaces were examined under a scanning electron microscope, and the frequency of fracture modes was compared using the Kruskal-Wallis and Mann-Whitney U tests. For the investigation of the bonded interface, four teeth were prepared by the same procedure used for the bond test specimens. The bonded interfaces were observed after an acid-base treatment or fracturing across the bonded interface, prior to investigation with a field-emission scanning electron microscope. For Single Bond, the bond strengths for mid-root dentine were significantly lower than for other locations (p < 0.05). For MF-102, there was no significant difference for all locations (p > 0.05). MF-102 bonded well to all locations of dentine while Single Bond showed a porous zone at the base of the hybrid layer. The bonds were not influenced by tubule orientation. The results indicate that the bond for Single Bond may be affected by its ability to penetrate demineralised dentine in different locations of a tooth. The self-etching primer of MF-102 produces a good bond and is independent of the position on the tooth. © 1999 Elsevier Science Ltd. All rights reserved.en_HK
dc.languageengen_HK
dc.publisherElsevier Ltd. The Journal's web site is located at http://www.elsevier.com/locate/jdenten_HK
dc.relation.ispartofJournal of Dentistryen_HK
dc.subjectChemicals And Cas Registry Numbersen_HK
dc.subject.meshAnalysis of Varianceen_HK
dc.subject.meshBicuspiden_HK
dc.subject.meshDental Bonding - methods - statistics & numerical dataen_HK
dc.subject.meshDentin - drug effects - ultrastructureen_HK
dc.subject.meshDentin-Bonding Agents - pharmacologyen_HK
dc.subject.meshHumansen_HK
dc.subject.meshMaxillaen_HK
dc.subject.meshMicroscopy, Electron, Scanningen_HK
dc.subject.meshTensile Strengthen_HK
dc.titleThe effect of dentine location and tubule orientation on the bond strengths between resin and dentineen_HK
dc.typeArticleen_HK
dc.identifier.emailBurrow, MF:mfburr58@hku.hken_HK
dc.identifier.authorityBurrow, MF=rp01306en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/S0300-5712(98)00060-8en_HK
dc.identifier.pmid10193103-
dc.identifier.scopuseid_2-s2.0-0033129016en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0033129016&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume27en_HK
dc.identifier.issue4en_HK
dc.identifier.spage265en_HK
dc.identifier.epage274en_HK
dc.identifier.isiWOS:000078986900003-
dc.publisher.placeUnited Kingdomen_HK
dc.identifier.scopusauthoridPhrukkanon, S=8837113100en_HK
dc.identifier.scopusauthoridBurrow, MF=7005876730en_HK
dc.identifier.scopusauthoridTyas, MJ=7006088443en_HK
dc.identifier.issnl0300-5712-

Export via OAI-PMH Interface in XML Formats