File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - A biomechanical study in a cadaveric model

TitlePalmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - A biomechanical study in a cadaveric model
Authors
Issue Date2003
PublisherWB Saunders Co Ltd. The Journal's web site is located at http://www.elsevier.com/locate/jhsb
Citation
Journal Of Hand Surgery, 2003, v. 28 B n. 3, p. 263-266 How to Cite?
AbstractThe stability of palmar plate fixation using a locking compression T-plate was compared with that of a conventional pahnar T-plate and a dorsal T-plate in a cadaveric model of an AO type C2 fracture of distal radius. The wrist axial load transmission through the radius was tested for each fixation. The results show that, under 100N axial load, the pahnar locking compression T-plate restores stability comparable to that of the intact radius, and is superior to conventional palmar or dorsal T-plates.
Persistent Identifierhttp://hdl.handle.net/10722/79625
ISSN
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorLeung, Fen_HK
dc.contributor.authorZhu, Len_HK
dc.contributor.authorHo, Hen_HK
dc.contributor.authorLu, WWen_HK
dc.contributor.authorChow, SPen_HK
dc.date.accessioned2010-09-06T07:56:45Z-
dc.date.available2010-09-06T07:56:45Z-
dc.date.issued2003en_HK
dc.identifier.citationJournal Of Hand Surgery, 2003, v. 28 B n. 3, p. 263-266en_HK
dc.identifier.issn0266-7681en_HK
dc.identifier.urihttp://hdl.handle.net/10722/79625-
dc.description.abstractThe stability of palmar plate fixation using a locking compression T-plate was compared with that of a conventional pahnar T-plate and a dorsal T-plate in a cadaveric model of an AO type C2 fracture of distal radius. The wrist axial load transmission through the radius was tested for each fixation. The results show that, under 100N axial load, the pahnar locking compression T-plate restores stability comparable to that of the intact radius, and is superior to conventional palmar or dorsal T-plates.en_HK
dc.languageengen_HK
dc.publisherWB Saunders Co Ltd. The Journal's web site is located at http://www.elsevier.com/locate/jhsben_HK
dc.relation.ispartofJournal of Hand Surgeryen_HK
dc.titlePalmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - A biomechanical study in a cadaveric modelen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0266-7681&volume=28B&issue=3&spage=263&epage=266&date=2003&atitle=Palmar+plate+fixation+of+AO+Type+C2+fracture+of+distal+radius+using+a+locking+compression+plate+-+A+biomechanical+study+in+a+cadaveric+model.en_HK
dc.identifier.emailLeung, F: klleunga@hku.hken_HK
dc.identifier.emailLu, WW: wwlu@hku.hken_HK
dc.identifier.emailChow, SP: spchow@hku.hken_HK
dc.identifier.authorityLeung, F=rp00297en_HK
dc.identifier.authorityLu, WW=rp00411en_HK
dc.identifier.authorityChow, SP=rp00064en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/S0266-7681(03)00011-1en_HK
dc.identifier.pmid12809662-
dc.identifier.scopuseid_2-s2.0-0038627493en_HK
dc.identifier.hkuros79206en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0038627493&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume28 Ben_HK
dc.identifier.issue3en_HK
dc.identifier.spage263en_HK
dc.identifier.epage266en_HK
dc.identifier.isiWOS:000183090800015-
dc.publisher.placeUnited Kingdomen_HK
dc.identifier.scopusauthoridLeung, F=7103078631en_HK
dc.identifier.scopusauthoridZhu, L=46261796500en_HK
dc.identifier.scopusauthoridHo, H=7401465207en_HK
dc.identifier.scopusauthoridLu, WW=7404215221en_HK
dc.identifier.scopusauthoridChow, SP=7201828376en_HK
dc.identifier.issnl0266-7681-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats