File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: A semi-automated method for analysis of intron 13 and intron 22 dinucleotide repeat polymorphisms of the factor VIII gene

TitleA semi-automated method for analysis of intron 13 and intron 22 dinucleotide repeat polymorphisms of the factor VIII gene
Authors
Keywordsfluorescent-labelled primers
Microsatellite repeat polymorphisms
multiplex PCR
semi-automated method
Issue Date1996
PublisherBlackwell Publishing Ltd. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLH
Citation
Clinical And Laboratory Haematology, 1996, v. 18 n. 2, p. 111-114 How to Cite?
AbstractA semi-automated method has been developed for the simultaneous analysis of two microsatellite repeat polymorphisms located in intron 13 and 22 of the Factor VIII gene. The fluorescent dyes, 6-FAM- and HEX- phosphoramidites were used to 5'-end label the respective 5' primers of these two microsatellite repeats and a multiplex polymerase chain reaction (PCR) devised for amplification. The PCR product was loaded onto the gel with DNA size marker labelled with ROX. A rural of 24 samples could be analysed simultaneously on an automated DNA sequencer. The results were computed using a dedicated software, with assignment of PCR product size in basepair. This method compares well with the conventional manual procedure using radio-labelled primers, but at the same time overcomes many of the inherent disadvantages associated with the latter method.
Persistent Identifierhttp://hdl.handle.net/10722/78578
ISSN
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorYip, Ben_HK
dc.contributor.authorChan, Ven_HK
dc.contributor.authorChan, TKen_HK
dc.date.accessioned2010-09-06T07:44:25Z-
dc.date.available2010-09-06T07:44:25Z-
dc.date.issued1996en_HK
dc.identifier.citationClinical And Laboratory Haematology, 1996, v. 18 n. 2, p. 111-114en_HK
dc.identifier.issn0141-9854en_HK
dc.identifier.urihttp://hdl.handle.net/10722/78578-
dc.description.abstractA semi-automated method has been developed for the simultaneous analysis of two microsatellite repeat polymorphisms located in intron 13 and 22 of the Factor VIII gene. The fluorescent dyes, 6-FAM- and HEX- phosphoramidites were used to 5'-end label the respective 5' primers of these two microsatellite repeats and a multiplex polymerase chain reaction (PCR) devised for amplification. The PCR product was loaded onto the gel with DNA size marker labelled with ROX. A rural of 24 samples could be analysed simultaneously on an automated DNA sequencer. The results were computed using a dedicated software, with assignment of PCR product size in basepair. This method compares well with the conventional manual procedure using radio-labelled primers, but at the same time overcomes many of the inherent disadvantages associated with the latter method.en_HK
dc.languageengen_HK
dc.publisherBlackwell Publishing Ltd. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLHen_HK
dc.relation.ispartofClinical and Laboratory Haematologyen_HK
dc.rightsClinical and Laboratory Haematology. Copyright © Blackwell Publishing Ltd.en_HK
dc.subjectfluorescent-labelled primers-
dc.subjectMicrosatellite repeat polymorphisms-
dc.subjectmultiplex PCR-
dc.subjectsemi-automated method-
dc.subject.meshAllelesen_HK
dc.subject.meshAutomationen_HK
dc.subject.meshDNA Mutational Analysis - methodsen_HK
dc.subject.meshDNA Primersen_HK
dc.subject.meshDinucleotide Repeatsen_HK
dc.subject.meshElectrophoresis, Polyacrylamide Gelen_HK
dc.subject.meshFactor VIII - geneticsen_HK
dc.subject.meshFemaleen_HK
dc.subject.meshFluorescent Dyesen_HK
dc.subject.meshGenotypeen_HK
dc.subject.meshHaplotypes - geneticsen_HK
dc.subject.meshHemophilia A - blood - geneticsen_HK
dc.subject.meshHumansen_HK
dc.subject.meshIntrons - geneticsen_HK
dc.subject.meshLeukocytes - chemistryen_HK
dc.subject.meshMaleen_HK
dc.subject.meshPolymerase Chain Reaction - methodsen_HK
dc.subject.meshSoftwareen_HK
dc.titleA semi-automated method for analysis of intron 13 and intron 22 dinucleotide repeat polymorphisms of the factor VIII geneen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0141-9854&volume=18&spage=4pp&epage=&date=1995&atitle=A+semi-automated+method+for+analysis+of+intron+13+and+intron+22+dinucleotide+repeat+polymorphisms+of+the+factor+VIII+geneen_HK
dc.identifier.emailChan, V:vnychana@hkucc.hku.hken_HK
dc.identifier.authorityChan, V=rp00320en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1046/j.1365-2257.1996.00163.x-
dc.identifier.pmid8866144en_HK
dc.identifier.scopuseid_2-s2.0-0029780388en_HK
dc.identifier.hkuros12279en_HK
dc.identifier.hkuros22984-
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0029780388&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume18en_HK
dc.identifier.issue2en_HK
dc.identifier.spage111en_HK
dc.identifier.epage114en_HK
dc.identifier.isiWOS:A1996VC72200009-
dc.publisher.placeUnited Kingdomen_HK
dc.identifier.scopusauthoridYip, B=16685586100en_HK
dc.identifier.scopusauthoridChan, V=7202654865en_HK
dc.identifier.scopusauthoridChan, TK=7402687762en_HK
dc.identifier.issnl0141-9854-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats