File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1046/j.1365-2257.1996.00163.x
- Scopus: eid_2-s2.0-0029780388
- PMID: 8866144
- WOS: WOS:A1996VC72200009
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: A semi-automated method for analysis of intron 13 and intron 22 dinucleotide repeat polymorphisms of the factor VIII gene
Title | A semi-automated method for analysis of intron 13 and intron 22 dinucleotide repeat polymorphisms of the factor VIII gene |
---|---|
Authors | |
Keywords | fluorescent-labelled primers Microsatellite repeat polymorphisms multiplex PCR semi-automated method |
Issue Date | 1996 |
Publisher | Blackwell Publishing Ltd. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLH |
Citation | Clinical And Laboratory Haematology, 1996, v. 18 n. 2, p. 111-114 How to Cite? |
Abstract | A semi-automated method has been developed for the simultaneous analysis of two microsatellite repeat polymorphisms located in intron 13 and 22 of the Factor VIII gene. The fluorescent dyes, 6-FAM- and HEX- phosphoramidites were used to 5'-end label the respective 5' primers of these two microsatellite repeats and a multiplex polymerase chain reaction (PCR) devised for amplification. The PCR product was loaded onto the gel with DNA size marker labelled with ROX. A rural of 24 samples could be analysed simultaneously on an automated DNA sequencer. The results were computed using a dedicated software, with assignment of PCR product size in basepair. This method compares well with the conventional manual procedure using radio-labelled primers, but at the same time overcomes many of the inherent disadvantages associated with the latter method. |
Persistent Identifier | http://hdl.handle.net/10722/78578 |
ISSN | |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yip, B | en_HK |
dc.contributor.author | Chan, V | en_HK |
dc.contributor.author | Chan, TK | en_HK |
dc.date.accessioned | 2010-09-06T07:44:25Z | - |
dc.date.available | 2010-09-06T07:44:25Z | - |
dc.date.issued | 1996 | en_HK |
dc.identifier.citation | Clinical And Laboratory Haematology, 1996, v. 18 n. 2, p. 111-114 | en_HK |
dc.identifier.issn | 0141-9854 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/78578 | - |
dc.description.abstract | A semi-automated method has been developed for the simultaneous analysis of two microsatellite repeat polymorphisms located in intron 13 and 22 of the Factor VIII gene. The fluorescent dyes, 6-FAM- and HEX- phosphoramidites were used to 5'-end label the respective 5' primers of these two microsatellite repeats and a multiplex polymerase chain reaction (PCR) devised for amplification. The PCR product was loaded onto the gel with DNA size marker labelled with ROX. A rural of 24 samples could be analysed simultaneously on an automated DNA sequencer. The results were computed using a dedicated software, with assignment of PCR product size in basepair. This method compares well with the conventional manual procedure using radio-labelled primers, but at the same time overcomes many of the inherent disadvantages associated with the latter method. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Blackwell Publishing Ltd. The Journal's web site is located at http://www.blackwellpublishing.com/journals/CLH | en_HK |
dc.relation.ispartof | Clinical and Laboratory Haematology | en_HK |
dc.rights | Clinical and Laboratory Haematology. Copyright © Blackwell Publishing Ltd. | en_HK |
dc.subject | fluorescent-labelled primers | - |
dc.subject | Microsatellite repeat polymorphisms | - |
dc.subject | multiplex PCR | - |
dc.subject | semi-automated method | - |
dc.subject.mesh | Alleles | en_HK |
dc.subject.mesh | Automation | en_HK |
dc.subject.mesh | DNA Mutational Analysis - methods | en_HK |
dc.subject.mesh | DNA Primers | en_HK |
dc.subject.mesh | Dinucleotide Repeats | en_HK |
dc.subject.mesh | Electrophoresis, Polyacrylamide Gel | en_HK |
dc.subject.mesh | Factor VIII - genetics | en_HK |
dc.subject.mesh | Female | en_HK |
dc.subject.mesh | Fluorescent Dyes | en_HK |
dc.subject.mesh | Genotype | en_HK |
dc.subject.mesh | Haplotypes - genetics | en_HK |
dc.subject.mesh | Hemophilia A - blood - genetics | en_HK |
dc.subject.mesh | Humans | en_HK |
dc.subject.mesh | Introns - genetics | en_HK |
dc.subject.mesh | Leukocytes - chemistry | en_HK |
dc.subject.mesh | Male | en_HK |
dc.subject.mesh | Polymerase Chain Reaction - methods | en_HK |
dc.subject.mesh | Software | en_HK |
dc.title | A semi-automated method for analysis of intron 13 and intron 22 dinucleotide repeat polymorphisms of the factor VIII gene | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0141-9854&volume=18&spage=4pp&epage=&date=1995&atitle=A+semi-automated+method+for+analysis+of+intron+13+and+intron+22+dinucleotide+repeat+polymorphisms+of+the+factor+VIII+gene | en_HK |
dc.identifier.email | Chan, V:vnychana@hkucc.hku.hk | en_HK |
dc.identifier.authority | Chan, V=rp00320 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1046/j.1365-2257.1996.00163.x | - |
dc.identifier.pmid | 8866144 | en_HK |
dc.identifier.scopus | eid_2-s2.0-0029780388 | en_HK |
dc.identifier.hkuros | 12279 | en_HK |
dc.identifier.hkuros | 22984 | - |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0029780388&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 18 | en_HK |
dc.identifier.issue | 2 | en_HK |
dc.identifier.spage | 111 | en_HK |
dc.identifier.epage | 114 | en_HK |
dc.identifier.isi | WOS:A1996VC72200009 | - |
dc.publisher.place | United Kingdom | en_HK |
dc.identifier.scopusauthorid | Yip, B=16685586100 | en_HK |
dc.identifier.scopusauthorid | Chan, V=7202654865 | en_HK |
dc.identifier.scopusauthorid | Chan, TK=7402687762 | en_HK |
dc.identifier.issnl | 0141-9854 | - |