Title | Design, fabrication, and assembly of a large oedometer |
---|---|
Authors | |
Keywords | Consolidation High consolidation stress Laboratory apparatus Large consolidometer |
Issue Date | 2006 |
Publisher | A S T M International. The Journal's web site is located at http://journalsip.astm.org/JOURNALS/GEOTECH/gtj%5Fhome.html |
Citation | Geotechnical Testing Journal, 2006, v. 29 n. 4, p. 298-305 How to Cite? |
Abstract | A typical Casagrande-type oedometer cell is 76 mm in diameter and 19 mm high. It may perform satisfactorily in the measurements of consolidation parameters of homogeneous fine-grained soil specimens up to a maximum applied vertical stress of approximately 3 MPa. However, when it is required to evaluate the load-deformation characteristics of soil specimens containing relative large-diameter grain particles and/or at a considerably higher stress level, the existing apparatus is evidently inadequate. Therefore, an oedometer of 425 mm in internal diameter was designed, fabricated, and assembled at The University of Hong Kong. The consolidation stress that can be applied is up to 13.5 MPa. Specimen preparation and measurement procedure have to be developed to cope with the new apparatus. The design, fabrication, and assembly of the large oedometer are documented and discussed in this paper. Moreover, experimental procedure developed and measurement data demonstrating the applicability of the new apparatus are presented. Copyright © 2006 by ASTM International. |
Persistent Identifier | http://hdl.handle.net/10722/70702 |
ISSN | 2023 Impact Factor: 1.3 2023 SCImago Journal Rankings: 0.547 |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ng, AMY | en_HK |
dc.contributor.author | Yeung, AT | en_HK |
dc.contributor.author | Lee, PKK | en_HK |
dc.contributor.author | Tham, LG | en_HK |
dc.date.accessioned | 2010-09-06T06:25:20Z | - |
dc.date.available | 2010-09-06T06:25:20Z | - |
dc.date.issued | 2006 | en_HK |
dc.identifier.citation | Geotechnical Testing Journal, 2006, v. 29 n. 4, p. 298-305 | en_HK |
dc.identifier.issn | 0149-6115 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/70702 | - |
dc.description.abstract | A typical Casagrande-type oedometer cell is 76 mm in diameter and 19 mm high. It may perform satisfactorily in the measurements of consolidation parameters of homogeneous fine-grained soil specimens up to a maximum applied vertical stress of approximately 3 MPa. However, when it is required to evaluate the load-deformation characteristics of soil specimens containing relative large-diameter grain particles and/or at a considerably higher stress level, the existing apparatus is evidently inadequate. Therefore, an oedometer of 425 mm in internal diameter was designed, fabricated, and assembled at The University of Hong Kong. The consolidation stress that can be applied is up to 13.5 MPa. Specimen preparation and measurement procedure have to be developed to cope with the new apparatus. The design, fabrication, and assembly of the large oedometer are documented and discussed in this paper. Moreover, experimental procedure developed and measurement data demonstrating the applicability of the new apparatus are presented. Copyright © 2006 by ASTM International. | en_HK |
dc.language | eng | en_HK |
dc.publisher | A S T M International. The Journal's web site is located at http://journalsip.astm.org/JOURNALS/GEOTECH/gtj%5Fhome.html | en_HK |
dc.relation.ispartof | Geotechnical Testing Journal | en_HK |
dc.subject | Consolidation | en_HK |
dc.subject | High consolidation stress | en_HK |
dc.subject | Laboratory apparatus | en_HK |
dc.subject | Large consolidometer | en_HK |
dc.title | Design, fabrication, and assembly of a large oedometer | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0149-6115&volume=29&issue=4&spage=298&epage=305&date=2006&atitle=Design,+fabrication,+and+assembly+of+a+large+oedometer | en_HK |
dc.identifier.email | Yeung, AT:yeungat@hkucc.hku.hk | en_HK |
dc.identifier.email | Lee, PKK:hreclkk@hkucc.hku.hk | en_HK |
dc.identifier.email | Tham, LG:hrectlg@hkucc.hku.hk | en_HK |
dc.identifier.authority | Yeung, AT=rp00203 | en_HK |
dc.identifier.authority | Lee, PKK=rp00141 | en_HK |
dc.identifier.authority | Tham, LG=rp00176 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.scopus | eid_2-s2.0-33845578171 | en_HK |
dc.identifier.hkuros | 115734 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-33845578171&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 29 | en_HK |
dc.identifier.issue | 4 | en_HK |
dc.identifier.spage | 298 | en_HK |
dc.identifier.epage | 305 | en_HK |
dc.publisher.place | United States | en_HK |
dc.identifier.scopusauthorid | Ng, AMY=15623591000 | en_HK |
dc.identifier.scopusauthorid | Yeung, AT=7102390361 | en_HK |
dc.identifier.scopusauthorid | Lee, PKK=24522826500 | en_HK |
dc.identifier.scopusauthorid | Tham, LG=7006213628 | en_HK |
dc.identifier.issnl | 0149-6115 | - |