File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Determination of silicate in water by ion exclusion chromatography with conductivity detection

TitleDetermination of silicate in water by ion exclusion chromatography with conductivity detection
Authors
KeywordsConductivity detection
Silicate
Water analysis
Issue Date2000
PublisherElsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/chroma
Citation
Journal Of Chromatography A, 2000, v. 874 n. 1, p. 143-147 How to Cite?
AbstractA novel method for the direct determination of silicate in water by ion exclusion chromatography with conductivity detection is reported. The method is simple and sensitive with good precision. The calibration graph was linear from 0.1000 μmol l-1 to 1000.0 μmol l-1 for silicate with a correlation coefficient of 0.997 (n=6). The detection limit was 0.02 μmol l-1. The method was successfully applied to the determination of silicate in mineral water, tap water, distilled water and seawater. The recovery was from 93 to 104% and the relative standard deviation was in the range of 1.1 to 4.4%. Copyright (C) 2000 Elsevier Science B.V.
Persistent Identifierhttp://hdl.handle.net/10722/68577
ISSN
2021 Impact Factor: 4.601
2020 SCImago Journal Rankings: 1.011
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorLi, HBen_HK
dc.contributor.authorChen, Fen_HK
dc.date.accessioned2010-09-06T06:05:50Z-
dc.date.available2010-09-06T06:05:50Z-
dc.date.issued2000en_HK
dc.identifier.citationJournal Of Chromatography A, 2000, v. 874 n. 1, p. 143-147en_HK
dc.identifier.issn0021-9673en_HK
dc.identifier.urihttp://hdl.handle.net/10722/68577-
dc.description.abstractA novel method for the direct determination of silicate in water by ion exclusion chromatography with conductivity detection is reported. The method is simple and sensitive with good precision. The calibration graph was linear from 0.1000 μmol l-1 to 1000.0 μmol l-1 for silicate with a correlation coefficient of 0.997 (n=6). The detection limit was 0.02 μmol l-1. The method was successfully applied to the determination of silicate in mineral water, tap water, distilled water and seawater. The recovery was from 93 to 104% and the relative standard deviation was in the range of 1.1 to 4.4%. Copyright (C) 2000 Elsevier Science B.V.en_HK
dc.languageengen_HK
dc.publisherElsevier BV. The Journal's web site is located at http://www.elsevier.com/locate/chromaen_HK
dc.relation.ispartofJournal of Chromatography Aen_HK
dc.rightsJournal of Chromatography A. Copyright © Elsevier BV.en_HK
dc.subjectConductivity detectionen_HK
dc.subjectSilicateen_HK
dc.subjectWater analysisen_HK
dc.titleDetermination of silicate in water by ion exclusion chromatography with conductivity detectionen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0021-9673&volume=874&issue=1&spage=143&epage=147&date=2000&atitle=Determination+of+silicate+in+water+by+ion+exclusion+chromatography+with+conductivity+detectionen_HK
dc.identifier.emailChen, F: sfchen@hku.hken_HK
dc.identifier.authorityChen, F=rp00672en_HK
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/S0021-9673(00)00078-9en_HK
dc.identifier.pmid10768508-
dc.identifier.scopuseid_2-s2.0-0034737357en_HK
dc.identifier.hkuros52868en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-0034737357&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume874en_HK
dc.identifier.issue1en_HK
dc.identifier.spage143en_HK
dc.identifier.epage147en_HK
dc.identifier.isiWOS:000086049600015-
dc.publisher.placeNetherlandsen_HK
dc.identifier.scopusauthoridLi, HB=25649944400en_HK
dc.identifier.scopusauthoridChen, F=7404907980en_HK
dc.identifier.issnl0021-9673-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats