File Download
There are no files associated with this item.
Supplementary
- Citations:
- Appears in Collections:
Article: Mechanical Disruption of Dentin Collagen Fibrils during Resin-Dentin Bond Testing
Title | Mechanical Disruption of Dentin Collagen Fibrils during Resin-Dentin Bond Testing |
---|---|
Authors | |
Issue Date | 2000 |
Publisher | Quintessence Publishing Co Ltd. The Journal's web site is located at http://www.quintessencepublishing.co.uk/catalog/product_info.php?cPath=3&products_id=243 |
Citation | Journal Of Adhesive Dentistry, 2000, v. 2 n. 3, p. 175-192 How to Cite? |
Abstract | Purpose: To determine if collagen fibrils on the dentin side of failed resin-dentin interfaces undergo mechanical disruption during microtensile bond testing. Materials and Methods: Extracted, caries-free human third molars were divided into four groups. The occlusal enamel was removed, leaving a flat dentin surface for bonding. Resin composite buildups were made after the acid-conditioned dentin was bonded with either Single Bond (S) or One-Step (0), and using either moist bonding (M) or air drying for 5 s (D). After storage in water for 24 h, the teeth were vertically sectioned into an array of 0.9 x 0.9 mm resin composite-dentin beams. They were stressed to failure using the nontrimming version of the microtensile bond test. Fractured dentin and resin composite sides of representative beams from each group that exhibited adhesive failures under light microscopy examination were prepared for scanning (SEM) and transmission electron microscopy (TEM). Results: A two-way ANOVA showed that moist bond strengths were significantly higher than those made to dry dentin (M > D; p < 0.001), but that there was no difference between the adhesives (S vs 0; p = 0.547). SEM analysis showed the presence of loose collagen fibrils within fractured hybrid layers in the dry groups, but not in the moist groups. TEM examination of the dry-bonded groups revealed collagen fibrils that were thinner and exhibited abnormally wide interfibrillar spaces when hybrid layers were intact. Within dry-bonded fractured hybrid layers, broad mechanical disruption zones could be seen, consisting of fibrils that were devoid of cross banding, defibrillation of the subfibrillar architecture, and gross disaggregation into microfibrils. In the moist-bonded groups, only short mechanical disruption zones were found along the torn edges of the collagen fibrils. The rest of the fibrils beyond the fracture site were intact and retained their periodicity. Mechanical testing of demineralized matrices yielded a maximum modulus of elasticity of 43.9 ±6.1 MPa. Conclusion: We speculate that adhesive resin has a protective function for demineralized collagen in wellinfiltrated hybrid layers. We propose that both the collagen and resin contribute to load sharing during stress application until the final moment of rupture. On the other hand, collagen fibrils in poorly infiltrated hybrid layers, being unsupported by resin, undergo various degrees of irreversible mechanical disruption depending on how the stress is dissipated. The collagen fibril network has a much lower modulus of elasticity compared to those of resin-infiltrated fibrils or the demineralized dentin. |
Persistent Identifier | http://hdl.handle.net/10722/66158 |
ISSN | 2023 Impact Factor: 2.5 2023 SCImago Journal Rankings: 0.793 |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Tay, FR | en_HK |
dc.contributor.author | Carvalho, RM | en_HK |
dc.contributor.author | Yiu, CKY | en_HK |
dc.contributor.author | King, NM | en_HK |
dc.contributor.author | Zhang, Y | en_HK |
dc.contributor.author | Agee, K | en_HK |
dc.contributor.author | Bouillaguet, S | en_HK |
dc.contributor.author | Pashley, DH | en_HK |
dc.date.accessioned | 2010-09-06T05:44:03Z | - |
dc.date.available | 2010-09-06T05:44:03Z | - |
dc.date.issued | 2000 | en_HK |
dc.identifier.citation | Journal Of Adhesive Dentistry, 2000, v. 2 n. 3, p. 175-192 | en_HK |
dc.identifier.issn | 1461-5185 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/66158 | - |
dc.description.abstract | Purpose: To determine if collagen fibrils on the dentin side of failed resin-dentin interfaces undergo mechanical disruption during microtensile bond testing. Materials and Methods: Extracted, caries-free human third molars were divided into four groups. The occlusal enamel was removed, leaving a flat dentin surface for bonding. Resin composite buildups were made after the acid-conditioned dentin was bonded with either Single Bond (S) or One-Step (0), and using either moist bonding (M) or air drying for 5 s (D). After storage in water for 24 h, the teeth were vertically sectioned into an array of 0.9 x 0.9 mm resin composite-dentin beams. They were stressed to failure using the nontrimming version of the microtensile bond test. Fractured dentin and resin composite sides of representative beams from each group that exhibited adhesive failures under light microscopy examination were prepared for scanning (SEM) and transmission electron microscopy (TEM). Results: A two-way ANOVA showed that moist bond strengths were significantly higher than those made to dry dentin (M > D; p < 0.001), but that there was no difference between the adhesives (S vs 0; p = 0.547). SEM analysis showed the presence of loose collagen fibrils within fractured hybrid layers in the dry groups, but not in the moist groups. TEM examination of the dry-bonded groups revealed collagen fibrils that were thinner and exhibited abnormally wide interfibrillar spaces when hybrid layers were intact. Within dry-bonded fractured hybrid layers, broad mechanical disruption zones could be seen, consisting of fibrils that were devoid of cross banding, defibrillation of the subfibrillar architecture, and gross disaggregation into microfibrils. In the moist-bonded groups, only short mechanical disruption zones were found along the torn edges of the collagen fibrils. The rest of the fibrils beyond the fracture site were intact and retained their periodicity. Mechanical testing of demineralized matrices yielded a maximum modulus of elasticity of 43.9 ±6.1 MPa. Conclusion: We speculate that adhesive resin has a protective function for demineralized collagen in wellinfiltrated hybrid layers. We propose that both the collagen and resin contribute to load sharing during stress application until the final moment of rupture. On the other hand, collagen fibrils in poorly infiltrated hybrid layers, being unsupported by resin, undergo various degrees of irreversible mechanical disruption depending on how the stress is dissipated. The collagen fibril network has a much lower modulus of elasticity compared to those of resin-infiltrated fibrils or the demineralized dentin. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Quintessence Publishing Co Ltd. The Journal's web site is located at http://www.quintessencepublishing.co.uk/catalog/product_info.php?cPath=3&products_id=243 | en_HK |
dc.relation.ispartof | Journal of Adhesive Dentistry | en_HK |
dc.subject.mesh | Acid Etching, Dental | en_HK |
dc.subject.mesh | Air | en_HK |
dc.subject.mesh | Analysis of Variance | en_HK |
dc.subject.mesh | Bisphenol A-Glycidyl Methacrylate - chemistry | en_HK |
dc.subject.mesh | Collagen - physiology - ultrastructure | en_HK |
dc.subject.mesh | Composite Resins - chemistry | en_HK |
dc.subject.mesh | Dental Bonding | en_HK |
dc.subject.mesh | Dentin - physiology - ultrastructure | en_HK |
dc.subject.mesh | Dentin-Bonding Agents - chemistry | en_HK |
dc.subject.mesh | Desiccation | en_HK |
dc.subject.mesh | Elasticity | en_HK |
dc.subject.mesh | Humans | en_HK |
dc.subject.mesh | Materials Testing | en_HK |
dc.subject.mesh | Methacrylates - chemistry | en_HK |
dc.subject.mesh | Microscopy, Electron | en_HK |
dc.subject.mesh | Microscopy, Electron, Scanning | en_HK |
dc.subject.mesh | Molar, Third | en_HK |
dc.subject.mesh | Statistics as Topic | en_HK |
dc.subject.mesh | Surface Properties | en_HK |
dc.subject.mesh | Tensile Strength | en_HK |
dc.subject.mesh | Water | en_HK |
dc.title | Mechanical Disruption of Dentin Collagen Fibrils during Resin-Dentin Bond Testing | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1461-5185&volume=2&spage=175&epage=192&date=2000&atitle=Mechanical+disruption+of+dentin+collagen+fibrils+during+resin-dentin+bond+testing | en_HK |
dc.identifier.email | Yiu, CKY: ckyyiu@hkucc.hku.hk | en_HK |
dc.identifier.email | King, NM: hhdbknm@hkucc.hku.hk | en_HK |
dc.identifier.authority | Yiu, CKY=rp00018 | en_HK |
dc.identifier.authority | King, NM=rp00006 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.pmid | 11317391 | - |
dc.identifier.scopus | eid_2-s2.0-0034279951 | en_HK |
dc.identifier.hkuros | 56115 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-0034279951&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 2 | en_HK |
dc.identifier.issue | 3 | en_HK |
dc.identifier.spage | 175 | en_HK |
dc.identifier.epage | 192 | en_HK |
dc.publisher.place | United Kingdom | en_HK |
dc.identifier.scopusauthorid | Tay, FR=7102091962 | en_HK |
dc.identifier.scopusauthorid | Carvalho, RM=7103357029 | en_HK |
dc.identifier.scopusauthorid | Yiu, CKY=7007115156 | en_HK |
dc.identifier.scopusauthorid | King, NM=7201762850 | en_HK |
dc.identifier.scopusauthorid | Zhang, Y=7601310723 | en_HK |
dc.identifier.scopusauthorid | Agee, K=35601532800 | en_HK |
dc.identifier.scopusauthorid | Bouillaguet, S=7004592630 | en_HK |
dc.identifier.scopusauthorid | Pashley, DH=35448600800 | en_HK |
dc.identifier.issnl | 1461-5185 | - |