File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

Article: The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty

TitleThe accuracy of extramedullary guides for tibial component placement in total knee arthroplasty
Authors
Issue Date2008
PublisherSpringer. The Journal's web site is located at http://www.springer.com/medicine/orthopedics/journal/264
Citation
International Orthopaedics, 2008, v. 32 n. 4, p. 467-471 How to Cite?
AbstractAnteroposterior radiographs that included the whole tibia were taken before and after 75 total knee arthroplasties in 48 patients. The same tibial extra-medullary alignment guide system was used in every knee. The average tibial component alignment was 0.4 (SD 2.5, range -4.9 to 6.4) degrees of valgus post-operatively. 59 tibial components (78.7%) had a tibial cut within 3 degrees from being perpendicular to the mechanical axis, ten were too valgus (13.3%) and six were too varus (8%). The chance of the tibial components becoming too varus was higher if there was lateral tibial bowing, compared with no tibial bowing (p=0.048). A smaller lateral width of the leg increased the chance of the tibial components becoming too valgus (p=0.047). © 2007 Springer-Verlag.
Persistent Identifierhttp://hdl.handle.net/10722/59457
ISSN
2023 Impact Factor: 2.0
2023 SCImago Journal Rankings: 0.877
PubMed Central ID
ISI Accession Number ID
References

 

DC FieldValueLanguage
dc.contributor.authorChiu, KYen_HK
dc.contributor.authorYau, WPen_HK
dc.contributor.authorNg, TPen_HK
dc.contributor.authorTang, WMen_HK
dc.date.accessioned2010-05-31T03:50:37Z-
dc.date.available2010-05-31T03:50:37Z-
dc.date.issued2008en_HK
dc.identifier.citationInternational Orthopaedics, 2008, v. 32 n. 4, p. 467-471en_HK
dc.identifier.issn0341-2695en_HK
dc.identifier.urihttp://hdl.handle.net/10722/59457-
dc.description.abstractAnteroposterior radiographs that included the whole tibia were taken before and after 75 total knee arthroplasties in 48 patients. The same tibial extra-medullary alignment guide system was used in every knee. The average tibial component alignment was 0.4 (SD 2.5, range -4.9 to 6.4) degrees of valgus post-operatively. 59 tibial components (78.7%) had a tibial cut within 3 degrees from being perpendicular to the mechanical axis, ten were too valgus (13.3%) and six were too varus (8%). The chance of the tibial components becoming too varus was higher if there was lateral tibial bowing, compared with no tibial bowing (p=0.048). A smaller lateral width of the leg increased the chance of the tibial components becoming too valgus (p=0.047). © 2007 Springer-Verlag.en_HK
dc.languageengen_HK
dc.publisherSpringer. The Journal's web site is located at http://www.springer.com/medicine/orthopedics/journal/264en_HK
dc.relation.ispartofInternational Orthopaedicsen_HK
dc.titleThe accuracy of extramedullary guides for tibial component placement in total knee arthroplastyen_HK
dc.typeArticleen_HK
dc.identifier.openurlhttp://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0341-2695&volume=32&issue=4&spage=467&epage=471&date=2008&atitle=The+accuracy+of+extramedullary+guides+for+tibial+component+placement+in+total+knee+arthroplasty.en_HK
dc.identifier.emailChiu, KY:pkychiu@hkucc.hku.hken_HK
dc.identifier.emailYau, WP:peterwpy@hkucc.hku.hken_HK
dc.identifier.authorityChiu, KY=rp00379en_HK
dc.identifier.authorityYau, WP=rp00500en_HK
dc.description.naturelink_to_OA_fulltext-
dc.identifier.doi10.1007/s00264-007-0354-5en_HK
dc.identifier.pmid17364176-
dc.identifier.pmcidPMC2532261-
dc.identifier.scopuseid_2-s2.0-46149121520en_HK
dc.identifier.hkuros146359en_HK
dc.relation.referenceshttp://www.scopus.com/mlt/select.url?eid=2-s2.0-46149121520&selection=ref&src=s&origin=recordpageen_HK
dc.identifier.volume32en_HK
dc.identifier.issue4en_HK
dc.identifier.spage467en_HK
dc.identifier.epage471en_HK
dc.identifier.isiWOS:000257205400007-
dc.publisher.placeGermanyen_HK
dc.identifier.scopusauthoridChiu, KY=7202988127en_HK
dc.identifier.scopusauthoridYau, WP=7005822441en_HK
dc.identifier.scopusauthoridNg, TP=24438193400en_HK
dc.identifier.scopusauthoridTang, WM=7403430820en_HK
dc.identifier.issnl0341-2695-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats