File Download
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1007/s00264-007-0354-5
- Scopus: eid_2-s2.0-46149121520
- PMID: 17364176
- WOS: WOS:000257205400007
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty
Title | The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty |
---|---|
Authors | |
Issue Date | 2008 |
Publisher | Springer. The Journal's web site is located at http://www.springer.com/medicine/orthopedics/journal/264 |
Citation | International Orthopaedics, 2008, v. 32 n. 4, p. 467-471 How to Cite? |
Abstract | Anteroposterior radiographs that included the whole tibia were taken before and after 75 total knee arthroplasties in 48 patients. The same tibial extra-medullary alignment guide system was used in every knee. The average tibial component alignment was 0.4 (SD 2.5, range -4.9 to 6.4) degrees of valgus post-operatively. 59 tibial components (78.7%) had a tibial cut within 3 degrees from being perpendicular to the mechanical axis, ten were too valgus (13.3%) and six were too varus (8%). The chance of the tibial components becoming too varus was higher if there was lateral tibial bowing, compared with no tibial bowing (p=0.048). A smaller lateral width of the leg increased the chance of the tibial components becoming too valgus (p=0.047). © 2007 Springer-Verlag. |
Persistent Identifier | http://hdl.handle.net/10722/59457 |
ISSN | 2023 Impact Factor: 2.0 2023 SCImago Journal Rankings: 0.877 |
PubMed Central ID | |
ISI Accession Number ID | |
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chiu, KY | en_HK |
dc.contributor.author | Yau, WP | en_HK |
dc.contributor.author | Ng, TP | en_HK |
dc.contributor.author | Tang, WM | en_HK |
dc.date.accessioned | 2010-05-31T03:50:37Z | - |
dc.date.available | 2010-05-31T03:50:37Z | - |
dc.date.issued | 2008 | en_HK |
dc.identifier.citation | International Orthopaedics, 2008, v. 32 n. 4, p. 467-471 | en_HK |
dc.identifier.issn | 0341-2695 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/59457 | - |
dc.description.abstract | Anteroposterior radiographs that included the whole tibia were taken before and after 75 total knee arthroplasties in 48 patients. The same tibial extra-medullary alignment guide system was used in every knee. The average tibial component alignment was 0.4 (SD 2.5, range -4.9 to 6.4) degrees of valgus post-operatively. 59 tibial components (78.7%) had a tibial cut within 3 degrees from being perpendicular to the mechanical axis, ten were too valgus (13.3%) and six were too varus (8%). The chance of the tibial components becoming too varus was higher if there was lateral tibial bowing, compared with no tibial bowing (p=0.048). A smaller lateral width of the leg increased the chance of the tibial components becoming too valgus (p=0.047). © 2007 Springer-Verlag. | en_HK |
dc.language | eng | en_HK |
dc.publisher | Springer. The Journal's web site is located at http://www.springer.com/medicine/orthopedics/journal/264 | en_HK |
dc.relation.ispartof | International Orthopaedics | en_HK |
dc.title | The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=0341-2695&volume=32&issue=4&spage=467&epage=471&date=2008&atitle=The+accuracy+of+extramedullary+guides+for+tibial+component+placement+in+total+knee+arthroplasty. | en_HK |
dc.identifier.email | Chiu, KY:pkychiu@hkucc.hku.hk | en_HK |
dc.identifier.email | Yau, WP:peterwpy@hkucc.hku.hk | en_HK |
dc.identifier.authority | Chiu, KY=rp00379 | en_HK |
dc.identifier.authority | Yau, WP=rp00500 | en_HK |
dc.description.nature | link_to_OA_fulltext | - |
dc.identifier.doi | 10.1007/s00264-007-0354-5 | en_HK |
dc.identifier.pmid | 17364176 | - |
dc.identifier.pmcid | PMC2532261 | - |
dc.identifier.scopus | eid_2-s2.0-46149121520 | en_HK |
dc.identifier.hkuros | 146359 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-46149121520&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 32 | en_HK |
dc.identifier.issue | 4 | en_HK |
dc.identifier.spage | 467 | en_HK |
dc.identifier.epage | 471 | en_HK |
dc.identifier.isi | WOS:000257205400007 | - |
dc.publisher.place | Germany | en_HK |
dc.identifier.scopusauthorid | Chiu, KY=7202988127 | en_HK |
dc.identifier.scopusauthorid | Yau, WP=7005822441 | en_HK |
dc.identifier.scopusauthorid | Ng, TP=24438193400 | en_HK |
dc.identifier.scopusauthorid | Tang, WM=7403430820 | en_HK |
dc.identifier.issnl | 0341-2695 | - |