File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1002/jmri.21527
- Scopus: eid_2-s2.0-57049118509
- PMID: 19025960
- WOS: WOS:000261270500028
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Measurement of common carotid artery lumen dynamics during the cardiac cycle using magnetic resonance TrueFISP cine imaging
Title | Measurement of common carotid artery lumen dynamics during the cardiac cycle using magnetic resonance TrueFISP cine imaging | ||||
---|---|---|---|---|---|
Authors | |||||
Keywords | Arterial dynamics Common carotid artery MRI TrueFISP cine imaging | ||||
Issue Date | 2008 | ||||
Publisher | John Wiley & Sons, Inc. The Journal's web site is located at http://www.interscience.wiley.com/jpages/1053-1807/ | ||||
Citation | Journal Of Magnetic Resonance Imaging, 2008, v. 28 n. 6, p. 1527-1532 How to Cite? | ||||
Abstract | Purpose: To demonstrate magnetic resonance (MR) measurements of vascular lumen dynamics in common carotid arteries by using true fast imaging with steady-state precession (TrueFISP) cine imaging with an aim to provide additional physiologic information on the vessels. Materials and Methods: The left and right common carotid arteries were studied in normal young men (N = 6; age = 21-24 years; body weight = 130-175 lbs) using electrocardiogram (ECG)-triggered TrueFISP cine imaging at 20 frames per cardiac cycle. Lumen area waveforms were characterized with specific time and amplitude ratios. Distension values were quantified. Results: Distension values were measured at 25.92 ± 2.58% and 27.58 ± 4.44% for the left and right common carotid arteries, respectively. These findings are consistent with those previously documented using ultrasound imaging in a similar age group. Consistent lumen area waveform characteristics were found among the subjects studied. Conclusion: These findings demonstrate for the first time that the use of TrueFISP cine imaging is a robust, rapid technique for quantifying carotid lumen area dynamics and distension, which may be valuable in characterizing and diagnosing cardiovascular diseases. © 2008 Wiley-Liss, Inc. | ||||
Persistent Identifier | http://hdl.handle.net/10722/58770 | ||||
ISSN | 2023 Impact Factor: 3.3 2023 SCImago Journal Rankings: 1.339 | ||||
ISI Accession Number ID |
Funding Information: Contract grant sponsor: Hong Kong Research Grant Council: Contract grant number: HKU 7794/07M. | ||||
References |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Chow, TY | en_HK |
dc.contributor.author | Cheung, JS | en_HK |
dc.contributor.author | Wu, Y | en_HK |
dc.contributor.author | Guo, H | en_HK |
dc.contributor.author | Chan, KC | en_HK |
dc.contributor.author | Hui, ES | en_HK |
dc.contributor.author | Wu, EX | en_HK |
dc.date.accessioned | 2010-05-31T03:36:36Z | - |
dc.date.available | 2010-05-31T03:36:36Z | - |
dc.date.issued | 2008 | en_HK |
dc.identifier.citation | Journal Of Magnetic Resonance Imaging, 2008, v. 28 n. 6, p. 1527-1532 | en_HK |
dc.identifier.issn | 1053-1807 | en_HK |
dc.identifier.uri | http://hdl.handle.net/10722/58770 | - |
dc.description.abstract | Purpose: To demonstrate magnetic resonance (MR) measurements of vascular lumen dynamics in common carotid arteries by using true fast imaging with steady-state precession (TrueFISP) cine imaging with an aim to provide additional physiologic information on the vessels. Materials and Methods: The left and right common carotid arteries were studied in normal young men (N = 6; age = 21-24 years; body weight = 130-175 lbs) using electrocardiogram (ECG)-triggered TrueFISP cine imaging at 20 frames per cardiac cycle. Lumen area waveforms were characterized with specific time and amplitude ratios. Distension values were quantified. Results: Distension values were measured at 25.92 ± 2.58% and 27.58 ± 4.44% for the left and right common carotid arteries, respectively. These findings are consistent with those previously documented using ultrasound imaging in a similar age group. Consistent lumen area waveform characteristics were found among the subjects studied. Conclusion: These findings demonstrate for the first time that the use of TrueFISP cine imaging is a robust, rapid technique for quantifying carotid lumen area dynamics and distension, which may be valuable in characterizing and diagnosing cardiovascular diseases. © 2008 Wiley-Liss, Inc. | en_HK |
dc.language | eng | en_HK |
dc.publisher | John Wiley & Sons, Inc. The Journal's web site is located at http://www.interscience.wiley.com/jpages/1053-1807/ | en_HK |
dc.relation.ispartof | Journal of Magnetic Resonance Imaging | en_HK |
dc.rights | Journal of Magnetic Resonance Imaging. Copyright © John Wiley & Sons, Inc. | en_HK |
dc.subject | Arterial dynamics | en_HK |
dc.subject | Common carotid artery | en_HK |
dc.subject | MRI | en_HK |
dc.subject | TrueFISP cine imaging | en_HK |
dc.subject.mesh | Adult | - |
dc.subject.mesh | Carotid artery, common - physiology | - |
dc.subject.mesh | Humans | - |
dc.subject.mesh | Image processing, computer-assisted | - |
dc.subject.mesh | Magnetic resonance imaging, cine - methods | - |
dc.title | Measurement of common carotid artery lumen dynamics during the cardiac cycle using magnetic resonance TrueFISP cine imaging | en_HK |
dc.type | Article | en_HK |
dc.identifier.openurl | http://library.hku.hk:4550/resserv?sid=HKU:IR&issn=1053-1807&volume=28&issue=6&spage=1527&epage=1532&date=2008&atitle=Measurement+of+common+carotid+artery+lumen+dynamics+during+the+cardiac+cycle+using+Magnetic+Resonance+TrueFISP+Cine+Imaging | en_HK |
dc.identifier.email | Wu, EX:ewu1@hkucc.hku.hk | en_HK |
dc.identifier.authority | Wu, EX=rp00193 | en_HK |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1002/jmri.21527 | en_HK |
dc.identifier.pmid | 19025960 | - |
dc.identifier.scopus | eid_2-s2.0-57049118509 | en_HK |
dc.identifier.hkuros | 161918 | en_HK |
dc.relation.references | http://www.scopus.com/mlt/select.url?eid=2-s2.0-57049118509&selection=ref&src=s&origin=recordpage | en_HK |
dc.identifier.volume | 28 | en_HK |
dc.identifier.issue | 6 | en_HK |
dc.identifier.spage | 1527 | en_HK |
dc.identifier.epage | 1532 | en_HK |
dc.identifier.isi | WOS:000261270500028 | - |
dc.publisher.place | United States | en_HK |
dc.identifier.scopusauthorid | Chow, TY=25722970200 | en_HK |
dc.identifier.scopusauthorid | Cheung, JS=16174280400 | en_HK |
dc.identifier.scopusauthorid | Wu, Y=8940205500 | en_HK |
dc.identifier.scopusauthorid | Guo, H=12774450700 | en_HK |
dc.identifier.scopusauthorid | Chan, KC=34968940300 | en_HK |
dc.identifier.scopusauthorid | Hui, ES=16175117100 | en_HK |
dc.identifier.scopusauthorid | Wu, EX=7202128034 | en_HK |
dc.identifier.issnl | 1053-1807 | - |