Article: Needle Segmentation Using GAN: Restoring Thin Instrument Visibility in Robotic Ultrasound

TitleNeedle Segmentation Using GAN: Restoring Thin Instrument Visibility in Robotic Ultrasound
Authors
KeywordsMedical robotics
needle segmentation
robotic ultrasound (US)
ultrasound segmentation
Issue Date2024
Citation
IEEE Transactions on Instrumentation and Measurement, 2024, v. 73, article no. 4012211 How to Cite?
AbstractUltrasound-guided percutaneous needle insertion is a standard procedure employed in both biopsy and ablation in clinical practices. However, due to the complex interaction between tissue and instrument, the needle may deviate from the in-plane view, resulting in a lack of close monitoring of the percutaneous needle. To address this challenge, we introduce a robot-assisted ultrasound (US) imaging system designed to seamlessly monitor the insertion process and autonomously restore the visibility of the inserted instrument when misalignment happens. To this end, the adversarial structure is presented to encourage the generation of segmentation masks that align consistently with the ground truth in high-order space. This study also systematically investigates the effects on segmentation performance by exploring various training loss functions and their combinations. When misalignment between the probe and the percutaneous needle is detected, the robot is triggered to perform transverse searching to optimize the positional and rotational adjustment to restore needle visibility. The experimental results on ex-vivo porcine samples demonstrate that the proposed method can precisely segment the percutaneous needle (with a tip error of 0.37 ± 0.29 mm and an angle error of 1.19 ±0.29 °). Furthermore, the needle appearance can be successfully restored under the repositioned probe pose in all 45 trials, with repositioning errors of 1.51 ±0.95 mm and 1.25 ±0.79°.
Persistent Identifierhttp://hdl.handle.net/10722/365422
ISSN
2023 Impact Factor: 5.6
2023 SCImago Journal Rankings: 1.536

 

DC FieldValueLanguage
dc.contributor.authorJiang, Zhongliang-
dc.contributor.authorLi, Xuesong-
dc.contributor.authorChu, Xiangyu-
dc.contributor.authorKarlas, Angelos-
dc.contributor.authorBi, Yuan-
dc.contributor.authorCheng, Yingsheng-
dc.contributor.authorSamuel Au, K. W.-
dc.contributor.authorNavab, Nassir-
dc.date.accessioned2025-11-05T06:56:01Z-
dc.date.available2025-11-05T06:56:01Z-
dc.date.issued2024-
dc.identifier.citationIEEE Transactions on Instrumentation and Measurement, 2024, v. 73, article no. 4012211-
dc.identifier.issn0018-9456-
dc.identifier.urihttp://hdl.handle.net/10722/365422-
dc.description.abstractUltrasound-guided percutaneous needle insertion is a standard procedure employed in both biopsy and ablation in clinical practices. However, due to the complex interaction between tissue and instrument, the needle may deviate from the in-plane view, resulting in a lack of close monitoring of the percutaneous needle. To address this challenge, we introduce a robot-assisted ultrasound (US) imaging system designed to seamlessly monitor the insertion process and autonomously restore the visibility of the inserted instrument when misalignment happens. To this end, the adversarial structure is presented to encourage the generation of segmentation masks that align consistently with the ground truth in high-order space. This study also systematically investigates the effects on segmentation performance by exploring various training loss functions and their combinations. When misalignment between the probe and the percutaneous needle is detected, the robot is triggered to perform transverse searching to optimize the positional and rotational adjustment to restore needle visibility. The experimental results on ex-vivo porcine samples demonstrate that the proposed method can precisely segment the percutaneous needle (with a tip error of 0.37 ± 0.29 mm and an angle error of 1.19 ±0.29 °). Furthermore, the needle appearance can be successfully restored under the repositioned probe pose in all 45 trials, with repositioning errors of 1.51 ±0.95 mm and 1.25 ±0.79°.-
dc.languageeng-
dc.relation.ispartofIEEE Transactions on Instrumentation and Measurement-
dc.subjectMedical robotics-
dc.subjectneedle segmentation-
dc.subjectrobotic ultrasound (US)-
dc.subjectultrasound segmentation-
dc.titleNeedle Segmentation Using GAN: Restoring Thin Instrument Visibility in Robotic Ultrasound-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1109/TIM.2024.3451569-
dc.identifier.scopuseid_2-s2.0-85208408711-
dc.identifier.volume73-
dc.identifier.spagearticle no. 4012211-
dc.identifier.epagearticle no. 4012211-
dc.identifier.eissn1557-9662-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats