File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Experimental and theoretical investigation of timing jitter inside a stretcher-compressor setup

TitleExperimental and theoretical investigation of timing jitter inside a stretcher-compressor setup
Authors
Issue Date2012
Citation
Optics Express, 2012, v. 20, n. 4, p. 3443-3455 How to Cite?
AbstractIn an optically synchronized short-pulse optical-parametric chirped-pulse amplification (OPCPA) system, we observe a few-100 fs-scale timing jitter. With an active timing stabilization system slow fluctuations are removed and the timing jitter can be reduced to 100 fs standard deviation (Std). As the main source for the timing fluctuations we could identify air turbulence in the stretcher-compressor setup inside the chirped pulse amplification (CPA) pump chain. This observation is supported by theoretical investigation of group delay changes for angular deviations occurring between the parallel gratings of a compressor or stretcher, as they can be introduced by air turbulence. © 2012 Optical Society of America.
Persistent Identifierhttp://hdl.handle.net/10722/364854

 

DC FieldValueLanguage
dc.contributor.authorKlingebiel, Sandro-
dc.contributor.authorAhmad, Izhar-
dc.contributor.authorWandt, Christoph-
dc.contributor.authorSkrobol, Christoph-
dc.contributor.authorTrushin, Sergei A.-
dc.contributor.authorMajor, Zsuzsanna-
dc.contributor.authorKrausz, Ferenc-
dc.contributor.authorKarsch, Stefan-
dc.date.accessioned2025-10-30T08:35:46Z-
dc.date.available2025-10-30T08:35:46Z-
dc.date.issued2012-
dc.identifier.citationOptics Express, 2012, v. 20, n. 4, p. 3443-3455-
dc.identifier.urihttp://hdl.handle.net/10722/364854-
dc.description.abstractIn an optically synchronized short-pulse optical-parametric chirped-pulse amplification (OPCPA) system, we observe a few-100 fs-scale timing jitter. With an active timing stabilization system slow fluctuations are removed and the timing jitter can be reduced to 100 fs standard deviation (Std). As the main source for the timing fluctuations we could identify air turbulence in the stretcher-compressor setup inside the chirped pulse amplification (CPA) pump chain. This observation is supported by theoretical investigation of group delay changes for angular deviations occurring between the parallel gratings of a compressor or stretcher, as they can be introduced by air turbulence. © 2012 Optical Society of America.-
dc.languageeng-
dc.relation.ispartofOptics Express-
dc.titleExperimental and theoretical investigation of timing jitter inside a stretcher-compressor setup-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1364/OE.20.003443-
dc.identifier.scopuseid_2-s2.0-84857326653-
dc.identifier.volume20-
dc.identifier.issue4-
dc.identifier.spage3443-
dc.identifier.epage3455-
dc.identifier.eissn1094-4087-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats