Article: Ultra-high-contrast few-cycle pulses for multipetawatt-class laser technology

TitleUltra-high-contrast few-cycle pulses for multipetawatt-class laser technology
Authors
Issue Date2011
Citation
Optics Letters, 2011, v. 36, n. 16, p. 3145-3147 How to Cite?
AbstractWe report the generation of few-cycle multiterawatt light pulses with a temporal contrast of 1010, when measured as close as 2 ps to the pulse's peak. Tens of picoseconds before the main pulse, the contrast value is expected to spread much beyond the measurement limit. Separate measurements of contrast improvement factors at different stages of the laser system indicate that real contrast values may reach 1019 and 1014, when measured 50 and 25 ps before the pulse's peak, respectively. The combination of the shortest pulse duration and the highest contrast renders our system a promising front-end architecture for future multipetawatt laser facilities. © 2011 Optical Society of America.
Persistent Identifierhttp://hdl.handle.net/10722/364828
ISSN
2023 Impact Factor: 3.1
2023 SCImago Journal Rankings: 1.040

 

DC FieldValueLanguage
dc.contributor.authorMikhailova, Julia M.-
dc.contributor.authorBuck, Alexander-
dc.contributor.authorBorot, Antonin-
dc.contributor.authorSchmid, Karl-
dc.contributor.authorSears, Christopher-
dc.contributor.authorTsakiris, George D.-
dc.contributor.authorKrausz, Ferenc-
dc.contributor.authorVeisz, Laszlo-
dc.date.accessioned2025-10-30T08:35:39Z-
dc.date.available2025-10-30T08:35:39Z-
dc.date.issued2011-
dc.identifier.citationOptics Letters, 2011, v. 36, n. 16, p. 3145-3147-
dc.identifier.issn0146-9592-
dc.identifier.urihttp://hdl.handle.net/10722/364828-
dc.description.abstractWe report the generation of few-cycle multiterawatt light pulses with a temporal contrast of 10<sup>10</sup>, when measured as close as 2 ps to the pulse's peak. Tens of picoseconds before the main pulse, the contrast value is expected to spread much beyond the measurement limit. Separate measurements of contrast improvement factors at different stages of the laser system indicate that real contrast values may reach 10<sup>19</sup> and 10<sup>14</sup>, when measured 50 and 25 ps before the pulse's peak, respectively. The combination of the shortest pulse duration and the highest contrast renders our system a promising front-end architecture for future multipetawatt laser facilities. © 2011 Optical Society of America.-
dc.languageeng-
dc.relation.ispartofOptics Letters-
dc.titleUltra-high-contrast few-cycle pulses for multipetawatt-class laser technology-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1364/OL.36.003145-
dc.identifier.scopuseid_2-s2.0-80051711283-
dc.identifier.volume36-
dc.identifier.issue16-
dc.identifier.spage3145-
dc.identifier.epage3147-
dc.identifier.eissn1539-4794-