File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1103/PhysRevLett.92.073902
- Scopus: eid_2-s2.0-4444298345
- Find via

Supplementary
-
Citations:
- Scopus: 0
- Appears in Collections:
Article: Observation of Light-Phase-Sensitive Photoemission from a Metal
| Title | Observation of Light-Phase-Sensitive Photoemission from a Metal |
|---|---|
| Authors | |
| Issue Date | 2004 |
| Citation | Physical Review Letters, 2004, v. 92, n. 7 How to Cite? |
| Abstract | We demonstrate that multiphoton-induced photoelectron emission from a gold surface caused by low-energy (unamplified) 4-fs, 750-nm laser pulses is sensitive to the timing of electric field oscillations with respect to the pulse peak. This observation confirms recent theoretical predictions and opens the door to measuring the absolute value of the carrier-envelope phase difference of few-cycle light pulses with a solid-state detector. © 2004 The American Physical Society. |
| Persistent Identifier | http://hdl.handle.net/10722/364700 |
| ISSN | 2023 Impact Factor: 8.1 2023 SCImago Journal Rankings: 3.040 |
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Apolonski, A. | - |
| dc.contributor.author | Dombi, P. | - |
| dc.contributor.author | Paulus, G. G. | - |
| dc.contributor.author | Kakehata, M. | - |
| dc.contributor.author | Holzwarth, R. | - |
| dc.contributor.author | Udem, Th | - |
| dc.contributor.author | Lemell, Ch | - |
| dc.contributor.author | Torizuka, K. | - |
| dc.contributor.author | Burgdörfer, J. | - |
| dc.contributor.author | Hänsch, T. W. | - |
| dc.contributor.author | Krausz, F. | - |
| dc.date.accessioned | 2025-10-30T08:34:59Z | - |
| dc.date.available | 2025-10-30T08:34:59Z | - |
| dc.date.issued | 2004 | - |
| dc.identifier.citation | Physical Review Letters, 2004, v. 92, n. 7 | - |
| dc.identifier.issn | 0031-9007 | - |
| dc.identifier.uri | http://hdl.handle.net/10722/364700 | - |
| dc.description.abstract | We demonstrate that multiphoton-induced photoelectron emission from a gold surface caused by low-energy (unamplified) 4-fs, 750-nm laser pulses is sensitive to the timing of electric field oscillations with respect to the pulse peak. This observation confirms recent theoretical predictions and opens the door to measuring the absolute value of the carrier-envelope phase difference of few-cycle light pulses with a solid-state detector. © 2004 The American Physical Society. | - |
| dc.language | eng | - |
| dc.relation.ispartof | Physical Review Letters | - |
| dc.title | Observation of Light-Phase-Sensitive Photoemission from a Metal | - |
| dc.type | Article | - |
| dc.description.nature | link_to_subscribed_fulltext | - |
| dc.identifier.doi | 10.1103/PhysRevLett.92.073902 | - |
| dc.identifier.scopus | eid_2-s2.0-4444298345 | - |
| dc.identifier.volume | 92 | - |
| dc.identifier.issue | 7 | - |
| dc.identifier.eissn | 1079-7114 | - |
