Conference Paper: Solid-state light phase detector

TitleSolid-state light phase detector
Authors
Issue Date2003
Citation
2003 European Quantum Electronics Conference Eqec 2003, 2003, p. 182 How to Cite?
AbstractDifferent approaches have been proposed and recently carried out experimentally to measure the value of the carrier-envelope phase (CEP) of a powerful (> 1 μJ) few-cycle pulse: generation of high harmonics and above-threshold ionization in gases. We demonstrate for the first time that electron emission from a gold surface induced by 4-fs 3 nJ pulse is sensitive to the timing of electric field oscillations with respect to the pulse peak and use this sensitivity for measuring the light field's oscillation phase at the pulse peak in low-energy laser pulses.
Persistent Identifierhttp://hdl.handle.net/10722/364373

 

DC FieldValueLanguage
dc.contributor.authorApolonski, A.-
dc.contributor.authorDombi, P.-
dc.contributor.authorPaulus, G. G.-
dc.contributor.authorKakehata, M.-
dc.contributor.authorHolzwarth, R.-
dc.contributor.authorUdem, Th-
dc.contributor.authorLemell, Ch-
dc.contributor.authorBurgdörfer, J.-
dc.contributor.authorHänsch, T. W.-
dc.contributor.authorKrausz, F.-
dc.date.accessioned2025-10-30T08:33:18Z-
dc.date.available2025-10-30T08:33:18Z-
dc.date.issued2003-
dc.identifier.citation2003 European Quantum Electronics Conference Eqec 2003, 2003, p. 182-
dc.identifier.urihttp://hdl.handle.net/10722/364373-
dc.description.abstractDifferent approaches have been proposed and recently carried out experimentally to measure the value of the carrier-envelope phase (CEP) of a powerful (> 1 μJ) few-cycle pulse: generation of high harmonics and above-threshold ionization in gases. We demonstrate for the first time that electron emission from a gold surface induced by 4-fs 3 nJ pulse is sensitive to the timing of electric field oscillations with respect to the pulse peak and use this sensitivity for measuring the light field's oscillation phase at the pulse peak in low-energy laser pulses.-
dc.languageeng-
dc.relation.ispartof2003 European Quantum Electronics Conference Eqec 2003-
dc.titleSolid-state light phase detector-
dc.typeConference_Paper-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1109/EQEC.2003.1314039-
dc.identifier.scopuseid_2-s2.0-84947247166-
dc.identifier.spage182-
dc.identifier.epage-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats