File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Multiple Defect‐Induced High‐Resolution Near‐Infrared Mechanoluminescent Materials for Non‐Destructive Detection of Blood Glucose and Lipids

TitleMultiple Defect‐Induced High‐Resolution Near‐Infrared Mechanoluminescent Materials for Non‐Destructive Detection of Blood Glucose and Lipids
Authors
Issue Date6-Nov-2024
PublisherWiley
Citation
Advanced Materials, 2024, v. 36, n. 50 How to Cite?
Abstract

Mechanoluminescence (ML) materials, known for their ability to convert mechanical energy into light, are increasingly recognized for their potential applications, such as in intelligent stress sensing, in vivo bioimaging, and stress non-destructive monitoring. However, the low signal-to-noise ratio (SNR) and narrow-band emission of single-defect-induced ML materials usually limit their biological-related practical applications. Here, these limitations will be addressed by modulating the microstructure evolution in Y3Ga3MgSiO12:Cr3+ through the [Si4++Mg2+] → [Ga3++Ga3+] chemical substitution strategy. Density functional theory (DFT) calculation reveals the defect types and dynamic charge migration processes. In addition, Y3Ga3MgSiO12: Cr3+ with continuously distributed “shallow-deep” defects (0.68–1.61 eV) can avoid persistent luminescence (PersL) and bright-field environment interference. Herein, such high SNR near-infrared broadband ML emission may provide a reliable way for high-quality biological non-destructive sensing and detection. Finally, benefiting from the different absorption of ML signals in glucose/lipid, one may find a novel non-invasive blood glucose/lipid testing technology in patients.


Persistent Identifierhttp://hdl.handle.net/10722/359152
ISSN
2023 Impact Factor: 27.4
2023 SCImago Journal Rankings: 9.191

 

DC FieldValueLanguage
dc.contributor.authorWu, Sheng-
dc.contributor.authorZhou, Guangyu-
dc.contributor.authorWu, Yafen-
dc.contributor.authorXiong, Puxian-
dc.contributor.authorXiao, Binli-
dc.contributor.authorZhou, Zhiyao-
dc.contributor.authorXiao, Yao-
dc.contributor.authorShao, Peishan-
dc.contributor.authorWang, Shouping-
dc.contributor.authorShao, Zhigang-
dc.contributor.authorWang, Yinzhen-
dc.contributor.authorWang, Feifei-
dc.date.accessioned2025-08-22T00:30:36Z-
dc.date.available2025-08-22T00:30:36Z-
dc.date.issued2024-11-06-
dc.identifier.citationAdvanced Materials, 2024, v. 36, n. 50-
dc.identifier.issn0935-9648-
dc.identifier.urihttp://hdl.handle.net/10722/359152-
dc.description.abstract<p>Mechanoluminescence (ML) materials, known for their ability to convert mechanical energy into light, are increasingly recognized for their potential applications, such as in intelligent stress sensing, in vivo bioimaging, and stress non-destructive monitoring. However, the low signal-to-noise ratio (SNR) and narrow-band emission of single-defect-induced ML materials usually limit their biological-related practical applications. Here, these limitations will be addressed by modulating the microstructure evolution in Y<sub>3</sub>Ga<sub>3</sub>MgSiO<sub>12</sub>:Cr<sup>3+</sup> through the [Si<sup>4+</sup>+Mg<sup>2+</sup>] → [Ga<sup>3+</sup>+Ga<sup>3+</sup>] chemical substitution strategy. Density functional theory (DFT) calculation reveals the defect types and dynamic charge migration processes. In addition, Y<sub>3</sub>Ga<sub>3</sub>MgSiO<sub>12</sub>: Cr<sup>3+</sup> with continuously distributed “shallow-deep” defects (0.68–1.61 eV) can avoid persistent luminescence (PersL) and bright-field environment interference. Herein, such high SNR near-infrared broadband ML emission may provide a reliable way for high-quality biological non-destructive sensing and detection. Finally, benefiting from the different absorption of ML signals in glucose/lipid, one may find a novel non-invasive blood glucose/lipid testing technology in patients.</p>-
dc.languageeng-
dc.publisherWiley-
dc.relation.ispartofAdvanced Materials-
dc.titleMultiple Defect‐Induced High‐Resolution Near‐Infrared Mechanoluminescent Materials for Non‐Destructive Detection of Blood Glucose and Lipids-
dc.typeArticle-
dc.identifier.doi10.1002/adma.202408508-
dc.identifier.volume36-
dc.identifier.issue50-
dc.identifier.eissn1521-4095-
dc.identifier.issnl0935-9648-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats