File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.11607/jomi.8555
- Scopus: eid_2-s2.0-85101731160
- PMID: 33600540
- WOS: WOS:000619859100001
- Find via

Supplementary
- Citations:
- Appears in Collections:
Article: Dynamic Navigation Guidance for Bone Reduction in Maxilla: Case Report
| Title | Dynamic Navigation Guidance for Bone Reduction in Maxilla: Case Report |
|---|---|
| Authors | |
| Keywords | accuracy bone reduction dynamic navigation full-arch rehabilitation immediate loading zygomatic implant |
| Issue Date | 2021 |
| Citation | International Journal of Oral and Maxillofacial Implants, 2021, v. 36, n. 1, p. e1-e6 How to Cite? |
| Abstract | This case report demonstrates the use of dynamic navigation guidance for bone reduction. Information about smile line position incorporated in a virtual plan and accurate transfer to the surgical field enhances the predictability of the treatment. A virtual wax-up was made, and implant positions along with bone reduction were planned accordingly. Residual teeth in the maxilla were extracted, and bone reduction and zygomatic implant placement were assisted by surgical navigation, while conventional implants were placed using the surgical template, followed by immediate loading. When surgical navigation is used for implant placement, navigated bone reduction can easily be incorporated in the workflow. The accuracy of bone reduction was evaluated together with the accuracy of two zygomatic implants assisted by a navigation system and four conventional implants assisted by a static template.The mean deviation between planned and performed bone reduction was 1.3 ± 0.39 mm (range: 0.8 to 1.7 mm). The accuracy of this procedure corresponds to the accuracy of guided implant placement and can be considered reliable after confirmation through clinical trials. Int J Oral Maxillo fac Implants 2021;36:e1-e6. dot 10.11607/jomi.8555 |
| Persistent Identifier | http://hdl.handle.net/10722/354391 |
| ISSN | 2023 Impact Factor: 1.7 2023 SCImago Journal Rankings: 0.702 |
| ISI Accession Number ID |
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Magic, Marko | - |
| dc.contributor.author | Wang, Feng | - |
| dc.contributor.author | Fan, Shengchi | - |
| dc.contributor.author | Wu, Yiqun | - |
| dc.date.accessioned | 2025-02-07T08:48:18Z | - |
| dc.date.available | 2025-02-07T08:48:18Z | - |
| dc.date.issued | 2021 | - |
| dc.identifier.citation | International Journal of Oral and Maxillofacial Implants, 2021, v. 36, n. 1, p. e1-e6 | - |
| dc.identifier.issn | 0882-2786 | - |
| dc.identifier.uri | http://hdl.handle.net/10722/354391 | - |
| dc.description.abstract | This case report demonstrates the use of dynamic navigation guidance for bone reduction. Information about smile line position incorporated in a virtual plan and accurate transfer to the surgical field enhances the predictability of the treatment. A virtual wax-up was made, and implant positions along with bone reduction were planned accordingly. Residual teeth in the maxilla were extracted, and bone reduction and zygomatic implant placement were assisted by surgical navigation, while conventional implants were placed using the surgical template, followed by immediate loading. When surgical navigation is used for implant placement, navigated bone reduction can easily be incorporated in the workflow. The accuracy of bone reduction was evaluated together with the accuracy of two zygomatic implants assisted by a navigation system and four conventional implants assisted by a static template.The mean deviation between planned and performed bone reduction was 1.3 ± 0.39 mm (range: 0.8 to 1.7 mm). The accuracy of this procedure corresponds to the accuracy of guided implant placement and can be considered reliable after confirmation through clinical trials. Int J Oral Maxillo fac Implants 2021;36:e1-e6. dot 10.11607/jomi.8555 | - |
| dc.language | eng | - |
| dc.relation.ispartof | International Journal of Oral and Maxillofacial Implants | - |
| dc.subject | accuracy | - |
| dc.subject | bone reduction | - |
| dc.subject | dynamic navigation | - |
| dc.subject | full-arch rehabilitation | - |
| dc.subject | immediate loading | - |
| dc.subject | zygomatic implant | - |
| dc.title | Dynamic Navigation Guidance for Bone Reduction in Maxilla: Case Report | - |
| dc.type | Article | - |
| dc.description.nature | link_to_subscribed_fulltext | - |
| dc.identifier.doi | 10.11607/jomi.8555 | - |
| dc.identifier.pmid | 33600540 | - |
| dc.identifier.scopus | eid_2-s2.0-85101731160 | - |
| dc.identifier.volume | 36 | - |
| dc.identifier.issue | 1 | - |
| dc.identifier.spage | e1 | - |
| dc.identifier.epage | e6 | - |
| dc.identifier.eissn | 1942-4434 | - |
| dc.identifier.isi | WOS:000619859100001 | - |
