File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.3390/jcm12165418
- Scopus: eid_2-s2.0-85169085945
- WOS: WOS:001056607100001
Supplementary
- Citations:
- Appears in Collections:
Article: The Accuracy of Zygomatic Implant Placement Assisted by Dynamic Computer-Aided Surgery: A Systematic Review and Meta-Analysis
| Title | The Accuracy of Zygomatic Implant Placement Assisted by Dynamic Computer-Aided Surgery: A Systematic Review and Meta-Analysis |
|---|---|
| Authors | |
| Keywords | computer-aided surgery edentulous guided surgery navigation zygomatic implant |
| Issue Date | 2023 |
| Citation | Journal of Clinical Medicine, 2023, v. 12, n. 16, article no. 5418 How to Cite? |
| Abstract | Purpose: The present systematic review aimed to investigate the accuracy of zygomatic implant (ZI) placement using dynamic computer-aided surgery (d-CAIS), static computer-aided surgery (s-CAIS), and a free-hand approach in patients with severe atrophic edentulous maxilla and/or deficient maxilla. Methods: Electronic and manual literature searches until May 2023 were performed in the PubMed/Medline, Scopus, Cochrane Library, and Web of Science databases. Clinical trials and cadaver studies were selected. The primary outcome was planned/placed deviation. Secondary outcomes were to evaluate the survival of ZI and surgical complications. Random-effects meta-analyses were conducted and meta-regression was utilized to compare fiducial registration amounts for d-CAIS and the different designs of s-CAIS. Results: A total of 14 studies with 511 ZIs were included (Nobel Biocare: 274, Southern Implant: 42, SIN Implant: 16, non-mentioned: 179). The pooled mean ZI deviations from the d-CAIS group were 1.81 mm (95% CI: 1.34–2.29) at the entry point and 2.95 mm (95% CI: 1.66–4.24) at the apex point, and angular deviations were 3.49 degrees (95% CI: 2.04–4.93). The pooled mean ZI deviations from the s-CAIS group were 1.19 mm (95% CI: 0.83–1.54) at the entry point and 1.80 mm (95% CI: 1.10–2.50) at the apex point, and angular deviations were 2.15 degrees (95% CI: 1.43–2.88). The pooled mean ZI deviations from the free-hand group were 2.04 mm (95% CI: 1.69–2.39) at the entry point and 3.23 mm (95% CI: 2.34–4.12) at the apex point, and angular deviations were 4.92 degrees (95% CI: 3.86–5.98). There was strong evidence of differences in the average entry, apex, and angular deviation between the navigation, surgical guide, and free-hand groups (p < 0.01). A significant inverse correlation was observed between the number of fiducial screws and the planned/placed deviation regarding entry, apex, and angular measurements. Conclusion: Using d-CAIS and modified s-CAIS for ZI surgery has shown clinically acceptable outcomes regarding average entry, apex, and angular deviations. The maximal deviation values were predominantly observed in the conventional s-CAIS. Surgeons should be mindful of potential deviations and complications regardless of the decision making in different guide approaches. |
| Persistent Identifier | http://hdl.handle.net/10722/354292 |
| ISI Accession Number ID |
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Fan, Shengchi | - |
| dc.contributor.author | Sáenz-Ravello, Gustavo | - |
| dc.contributor.author | Diaz, Leonardo | - |
| dc.contributor.author | Wu, Yiqun | - |
| dc.contributor.author | Davó, Rubén | - |
| dc.contributor.author | Wang, Feng | - |
| dc.contributor.author | Magic, Marko | - |
| dc.contributor.author | Al-Nawas, Bilal | - |
| dc.contributor.author | Kämmerer, Peer W. | - |
| dc.date.accessioned | 2025-02-07T08:47:42Z | - |
| dc.date.available | 2025-02-07T08:47:42Z | - |
| dc.date.issued | 2023 | - |
| dc.identifier.citation | Journal of Clinical Medicine, 2023, v. 12, n. 16, article no. 5418 | - |
| dc.identifier.uri | http://hdl.handle.net/10722/354292 | - |
| dc.description.abstract | Purpose: The present systematic review aimed to investigate the accuracy of zygomatic implant (ZI) placement using dynamic computer-aided surgery (d-CAIS), static computer-aided surgery (s-CAIS), and a free-hand approach in patients with severe atrophic edentulous maxilla and/or deficient maxilla. Methods: Electronic and manual literature searches until May 2023 were performed in the PubMed/Medline, Scopus, Cochrane Library, and Web of Science databases. Clinical trials and cadaver studies were selected. The primary outcome was planned/placed deviation. Secondary outcomes were to evaluate the survival of ZI and surgical complications. Random-effects meta-analyses were conducted and meta-regression was utilized to compare fiducial registration amounts for d-CAIS and the different designs of s-CAIS. Results: A total of 14 studies with 511 ZIs were included (Nobel Biocare: 274, Southern Implant: 42, SIN Implant: 16, non-mentioned: 179). The pooled mean ZI deviations from the d-CAIS group were 1.81 mm (95% CI: 1.34–2.29) at the entry point and 2.95 mm (95% CI: 1.66–4.24) at the apex point, and angular deviations were 3.49 degrees (95% CI: 2.04–4.93). The pooled mean ZI deviations from the s-CAIS group were 1.19 mm (95% CI: 0.83–1.54) at the entry point and 1.80 mm (95% CI: 1.10–2.50) at the apex point, and angular deviations were 2.15 degrees (95% CI: 1.43–2.88). The pooled mean ZI deviations from the free-hand group were 2.04 mm (95% CI: 1.69–2.39) at the entry point and 3.23 mm (95% CI: 2.34–4.12) at the apex point, and angular deviations were 4.92 degrees (95% CI: 3.86–5.98). There was strong evidence of differences in the average entry, apex, and angular deviation between the navigation, surgical guide, and free-hand groups (p < 0.01). A significant inverse correlation was observed between the number of fiducial screws and the planned/placed deviation regarding entry, apex, and angular measurements. Conclusion: Using d-CAIS and modified s-CAIS for ZI surgery has shown clinically acceptable outcomes regarding average entry, apex, and angular deviations. The maximal deviation values were predominantly observed in the conventional s-CAIS. Surgeons should be mindful of potential deviations and complications regardless of the decision making in different guide approaches. | - |
| dc.language | eng | - |
| dc.relation.ispartof | Journal of Clinical Medicine | - |
| dc.subject | computer-aided surgery | - |
| dc.subject | edentulous | - |
| dc.subject | guided surgery | - |
| dc.subject | navigation | - |
| dc.subject | zygomatic implant | - |
| dc.title | The Accuracy of Zygomatic Implant Placement Assisted by Dynamic Computer-Aided Surgery: A Systematic Review and Meta-Analysis | - |
| dc.type | Article | - |
| dc.description.nature | link_to_subscribed_fulltext | - |
| dc.identifier.doi | 10.3390/jcm12165418 | - |
| dc.identifier.scopus | eid_2-s2.0-85169085945 | - |
| dc.identifier.volume | 12 | - |
| dc.identifier.issue | 16 | - |
| dc.identifier.spage | article no. 5418 | - |
| dc.identifier.epage | article no. 5418 | - |
| dc.identifier.eissn | 2077-0383 | - |
| dc.identifier.isi | WOS:001056607100001 | - |