File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1111/clr.13259
- Scopus: eid_2-s2.0-85050095518
- PMID: 29774595
- WOS: WOS:000439500700002
- Find via

Supplementary
- Citations:
- Appears in Collections:
Article: Long-term Schneiderian membrane thickness changes following zygomatic implant placement: A retrospective radiographic analysis using cone beam computed tomography
| Title | Long-term Schneiderian membrane thickness changes following zygomatic implant placement: A retrospective radiographic analysis using cone beam computed tomography |
|---|---|
| Authors | |
| Keywords | complications maxillary sinus radiographic analysis Schneiderian membrane thickness zygomatic implants |
| Issue Date | 2018 |
| Citation | Clinical Oral Implants Research, 2018, v. 29, n. 7, p. 679-687 How to Cite? |
| Abstract | Objectives: The purpose of this retrospective study was to evaluate the long-term changes in the thickness of Schneiderian membranes after zygomatic implant placement using cone beam computed tomography (CBCT). Material and methods: Twenty-five consecutive patients were included in this study. All the patients underwent bilateral zygomatic implant placement. Schneiderian membrane thickness (SMT) in 49 maxillary sinuses (one sinus was not included because of early loss of the zygomatic implants) was measured using CBCT before and at least 1 year after zygomatic implant placement. Ostium patency of each sinus was also evaluated and recorded. Results: In total, 84 zygomatic implants and 30 regular implants were placed in included patients. Two unilateral maxillary zygomatic implants in one patient were removed 2 months after implant placement. The SMT increased from 1.03 mm (inter-quartile range: 1.57 mm) to 1.33 mm (inter-quartile range: 1.98 mm) after a median follow-up time of 23.00 months (inter-quartile range: 14 months), and the difference was statistically significant. Before zygomatic implant insertion, 24.5% (12/49) of sinuses had SMT greater than 2 mm, whereas this value was 28.6% (14/49) after zygomatic implant placement. The percentage of sinuses observed with ostium patency also increased from 2.0% (1/49) to 12.2% (6/49). Conclusions: Chronic Schneiderian membrane thickening could result from zygomatic implant insertion. Intensive postoperative care and clinical and radiographic monitoring are recommended after zygomatic implant placement. |
| Persistent Identifier | http://hdl.handle.net/10722/354121 |
| ISSN | 2023 Impact Factor: 4.8 2023 SCImago Journal Rankings: 1.865 |
| ISI Accession Number ID |
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Zhao, Kai | - |
| dc.contributor.author | Lian, Meifei | - |
| dc.contributor.author | Fan, Shengchi | - |
| dc.contributor.author | Huang, Wei | - |
| dc.contributor.author | Wang, Feng | - |
| dc.contributor.author | Wu, Yiqun | - |
| dc.date.accessioned | 2025-02-07T08:46:35Z | - |
| dc.date.available | 2025-02-07T08:46:35Z | - |
| dc.date.issued | 2018 | - |
| dc.identifier.citation | Clinical Oral Implants Research, 2018, v. 29, n. 7, p. 679-687 | - |
| dc.identifier.issn | 0905-7161 | - |
| dc.identifier.uri | http://hdl.handle.net/10722/354121 | - |
| dc.description.abstract | Objectives: The purpose of this retrospective study was to evaluate the long-term changes in the thickness of Schneiderian membranes after zygomatic implant placement using cone beam computed tomography (CBCT). Material and methods: Twenty-five consecutive patients were included in this study. All the patients underwent bilateral zygomatic implant placement. Schneiderian membrane thickness (SMT) in 49 maxillary sinuses (one sinus was not included because of early loss of the zygomatic implants) was measured using CBCT before and at least 1 year after zygomatic implant placement. Ostium patency of each sinus was also evaluated and recorded. Results: In total, 84 zygomatic implants and 30 regular implants were placed in included patients. Two unilateral maxillary zygomatic implants in one patient were removed 2 months after implant placement. The SMT increased from 1.03 mm (inter-quartile range: 1.57 mm) to 1.33 mm (inter-quartile range: 1.98 mm) after a median follow-up time of 23.00 months (inter-quartile range: 14 months), and the difference was statistically significant. Before zygomatic implant insertion, 24.5% (12/49) of sinuses had SMT greater than 2 mm, whereas this value was 28.6% (14/49) after zygomatic implant placement. The percentage of sinuses observed with ostium patency also increased from 2.0% (1/49) to 12.2% (6/49). Conclusions: Chronic Schneiderian membrane thickening could result from zygomatic implant insertion. Intensive postoperative care and clinical and radiographic monitoring are recommended after zygomatic implant placement. | - |
| dc.language | eng | - |
| dc.relation.ispartof | Clinical Oral Implants Research | - |
| dc.subject | complications | - |
| dc.subject | maxillary sinus | - |
| dc.subject | radiographic analysis | - |
| dc.subject | Schneiderian membrane thickness | - |
| dc.subject | zygomatic implants | - |
| dc.title | Long-term Schneiderian membrane thickness changes following zygomatic implant placement: A retrospective radiographic analysis using cone beam computed tomography | - |
| dc.type | Article | - |
| dc.description.nature | link_to_subscribed_fulltext | - |
| dc.identifier.doi | 10.1111/clr.13259 | - |
| dc.identifier.pmid | 29774595 | - |
| dc.identifier.scopus | eid_2-s2.0-85050095518 | - |
| dc.identifier.volume | 29 | - |
| dc.identifier.issue | 7 | - |
| dc.identifier.spage | 679 | - |
| dc.identifier.epage | 687 | - |
| dc.identifier.eissn | 1600-0501 | - |
| dc.identifier.isi | WOS:000439500700002 | - |
