File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Long-term Schneiderian membrane thickness changes following zygomatic implant placement: A retrospective radiographic analysis using cone beam computed tomography

TitleLong-term Schneiderian membrane thickness changes following zygomatic implant placement: A retrospective radiographic analysis using cone beam computed tomography
Authors
Keywordscomplications
maxillary sinus
radiographic analysis
Schneiderian membrane thickness
zygomatic implants
Issue Date2018
Citation
Clinical Oral Implants Research, 2018, v. 29, n. 7, p. 679-687 How to Cite?
AbstractObjectives: The purpose of this retrospective study was to evaluate the long-term changes in the thickness of Schneiderian membranes after zygomatic implant placement using cone beam computed tomography (CBCT). Material and methods: Twenty-five consecutive patients were included in this study. All the patients underwent bilateral zygomatic implant placement. Schneiderian membrane thickness (SMT) in 49 maxillary sinuses (one sinus was not included because of early loss of the zygomatic implants) was measured using CBCT before and at least 1 year after zygomatic implant placement. Ostium patency of each sinus was also evaluated and recorded. Results: In total, 84 zygomatic implants and 30 regular implants were placed in included patients. Two unilateral maxillary zygomatic implants in one patient were removed 2 months after implant placement. The SMT increased from 1.03 mm (inter-quartile range: 1.57 mm) to 1.33 mm (inter-quartile range: 1.98 mm) after a median follow-up time of 23.00 months (inter-quartile range: 14 months), and the difference was statistically significant. Before zygomatic implant insertion, 24.5% (12/49) of sinuses had SMT greater than 2 mm, whereas this value was 28.6% (14/49) after zygomatic implant placement. The percentage of sinuses observed with ostium patency also increased from 2.0% (1/49) to 12.2% (6/49). Conclusions: Chronic Schneiderian membrane thickening could result from zygomatic implant insertion. Intensive postoperative care and clinical and radiographic monitoring are recommended after zygomatic implant placement.
Persistent Identifierhttp://hdl.handle.net/10722/354121
ISSN
2023 Impact Factor: 4.8
2023 SCImago Journal Rankings: 1.865
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorZhao, Kai-
dc.contributor.authorLian, Meifei-
dc.contributor.authorFan, Shengchi-
dc.contributor.authorHuang, Wei-
dc.contributor.authorWang, Feng-
dc.contributor.authorWu, Yiqun-
dc.date.accessioned2025-02-07T08:46:35Z-
dc.date.available2025-02-07T08:46:35Z-
dc.date.issued2018-
dc.identifier.citationClinical Oral Implants Research, 2018, v. 29, n. 7, p. 679-687-
dc.identifier.issn0905-7161-
dc.identifier.urihttp://hdl.handle.net/10722/354121-
dc.description.abstractObjectives: The purpose of this retrospective study was to evaluate the long-term changes in the thickness of Schneiderian membranes after zygomatic implant placement using cone beam computed tomography (CBCT). Material and methods: Twenty-five consecutive patients were included in this study. All the patients underwent bilateral zygomatic implant placement. Schneiderian membrane thickness (SMT) in 49 maxillary sinuses (one sinus was not included because of early loss of the zygomatic implants) was measured using CBCT before and at least 1 year after zygomatic implant placement. Ostium patency of each sinus was also evaluated and recorded. Results: In total, 84 zygomatic implants and 30 regular implants were placed in included patients. Two unilateral maxillary zygomatic implants in one patient were removed 2 months after implant placement. The SMT increased from 1.03 mm (inter-quartile range: 1.57 mm) to 1.33 mm (inter-quartile range: 1.98 mm) after a median follow-up time of 23.00 months (inter-quartile range: 14 months), and the difference was statistically significant. Before zygomatic implant insertion, 24.5% (12/49) of sinuses had SMT greater than 2 mm, whereas this value was 28.6% (14/49) after zygomatic implant placement. The percentage of sinuses observed with ostium patency also increased from 2.0% (1/49) to 12.2% (6/49). Conclusions: Chronic Schneiderian membrane thickening could result from zygomatic implant insertion. Intensive postoperative care and clinical and radiographic monitoring are recommended after zygomatic implant placement.-
dc.languageeng-
dc.relation.ispartofClinical Oral Implants Research-
dc.subjectcomplications-
dc.subjectmaxillary sinus-
dc.subjectradiographic analysis-
dc.subjectSchneiderian membrane thickness-
dc.subjectzygomatic implants-
dc.titleLong-term Schneiderian membrane thickness changes following zygomatic implant placement: A retrospective radiographic analysis using cone beam computed tomography-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1111/clr.13259-
dc.identifier.pmid29774595-
dc.identifier.scopuseid_2-s2.0-85050095518-
dc.identifier.volume29-
dc.identifier.issue7-
dc.identifier.spage679-
dc.identifier.epage687-
dc.identifier.eissn1600-0501-
dc.identifier.isiWOS:000439500700002-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats