File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.11607/jomi.3084
- Scopus: eid_2-s2.0-84899467821
- PMID: 24066323
- WOS: WOS:000324733800033
- Find via

Supplementary
- Citations:
- Appears in Collections:
Article: Dental implant performance in vertically distracted fibular grafts after mandibular reconstruction: A pilot series of 12 patients
| Title | Dental implant performance in vertically distracted fibular grafts after mandibular reconstruction: A pilot series of 12 patients |
|---|---|
| Authors | |
| Keywords | Clinical parameters Dental implants Distraction osteogenesis Marginal bone level Vertically distracted fibula |
| Issue Date | 2013 |
| Citation | International Journal of Oral and Maxillofacial Implants, 2013, v. 28, n. 5, p. 1311-1321 How to Cite? |
| Abstract | Purpose: To clinically and radiographically evaluate the performance of loaded dental implants placed in vertically distracted fibular grafts after mandibular reconstruction, and to evaluate patient satisfaction with implant function and esthetics after oral rehabilitation. Materials and Methods: This retrospective study involved patients who received implants in vertically distracted fibular bone after mandibular reconstruction between February 2006 and January 2008. Clinical assessments were performed 6 months after loading and annually thereafter. Patient satisfaction was evaluated with respect to function, phonetics, facial contour esthetics, and oral hygiene practices. The data were evaluated statistically. Results: Thirty-seven dental implants were inserted in 12 patients (mean age, 42.9 ± 8.0 years). Three patients were completely edentulous and nine were partially edentulous. The low mean plaque score (< 20%) indicated a good level of oral hygiene during the mean follow-up period of 42.1 ± 4.1 months. Probing depths and modified Sulcus Bleeding Index increased slightly at follow-up, but there was no significant difference in either parameter at years 1 and 3. After 1 year, the average marginal bone loss was 0.8 ± 0.3 mm (range, 0.2 to 2.1 mm); this increased to 0.9 ± 0.4 mm (range, 0.5 to 2.4 mm) in year 3, which was not a significant difference. The cumulative survival rate was 100% and the cumulative success rate was 84.8%. Seven of the 12 patients were fully satisfied with the function and esthetics of the restoration. Conclusions: On the basis of the present study, implant placement in vertically distracted fibulae for mandibular reconstruction may be considered a predictable option in terms of mid- to long-term implant survival and success rates. © 2013 by Quintessence Publishing Co Inc. |
| Persistent Identifier | http://hdl.handle.net/10722/354114 |
| ISSN | 2023 Impact Factor: 1.7 2023 SCImago Journal Rankings: 0.702 |
| ISI Accession Number ID |
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Wang, Feng | - |
| dc.contributor.author | Wu, Yiqun | - |
| dc.contributor.author | Zhang, Chenping | - |
| dc.contributor.author | Zhang, Zhiyong | - |
| dc.date.accessioned | 2025-02-07T08:46:33Z | - |
| dc.date.available | 2025-02-07T08:46:33Z | - |
| dc.date.issued | 2013 | - |
| dc.identifier.citation | International Journal of Oral and Maxillofacial Implants, 2013, v. 28, n. 5, p. 1311-1321 | - |
| dc.identifier.issn | 0882-2786 | - |
| dc.identifier.uri | http://hdl.handle.net/10722/354114 | - |
| dc.description.abstract | Purpose: To clinically and radiographically evaluate the performance of loaded dental implants placed in vertically distracted fibular grafts after mandibular reconstruction, and to evaluate patient satisfaction with implant function and esthetics after oral rehabilitation. Materials and Methods: This retrospective study involved patients who received implants in vertically distracted fibular bone after mandibular reconstruction between February 2006 and January 2008. Clinical assessments were performed 6 months after loading and annually thereafter. Patient satisfaction was evaluated with respect to function, phonetics, facial contour esthetics, and oral hygiene practices. The data were evaluated statistically. Results: Thirty-seven dental implants were inserted in 12 patients (mean age, 42.9 ± 8.0 years). Three patients were completely edentulous and nine were partially edentulous. The low mean plaque score (< 20%) indicated a good level of oral hygiene during the mean follow-up period of 42.1 ± 4.1 months. Probing depths and modified Sulcus Bleeding Index increased slightly at follow-up, but there was no significant difference in either parameter at years 1 and 3. After 1 year, the average marginal bone loss was 0.8 ± 0.3 mm (range, 0.2 to 2.1 mm); this increased to 0.9 ± 0.4 mm (range, 0.5 to 2.4 mm) in year 3, which was not a significant difference. The cumulative survival rate was 100% and the cumulative success rate was 84.8%. Seven of the 12 patients were fully satisfied with the function and esthetics of the restoration. Conclusions: On the basis of the present study, implant placement in vertically distracted fibulae for mandibular reconstruction may be considered a predictable option in terms of mid- to long-term implant survival and success rates. © 2013 by Quintessence Publishing Co Inc. | - |
| dc.language | eng | - |
| dc.relation.ispartof | International Journal of Oral and Maxillofacial Implants | - |
| dc.subject | Clinical parameters | - |
| dc.subject | Dental implants | - |
| dc.subject | Distraction osteogenesis | - |
| dc.subject | Marginal bone level | - |
| dc.subject | Vertically distracted fibula | - |
| dc.title | Dental implant performance in vertically distracted fibular grafts after mandibular reconstruction: A pilot series of 12 patients | - |
| dc.type | Article | - |
| dc.description.nature | link_to_subscribed_fulltext | - |
| dc.identifier.doi | 10.11607/jomi.3084 | - |
| dc.identifier.pmid | 24066323 | - |
| dc.identifier.scopus | eid_2-s2.0-84899467821 | - |
| dc.identifier.volume | 28 | - |
| dc.identifier.issue | 5 | - |
| dc.identifier.spage | 1311 | - |
| dc.identifier.epage | 1321 | - |
| dc.identifier.isi | WOS:000324733800033 | - |
