File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.ejrad.2020.109489
- Scopus: eid_2-s2.0-85098595464
- PMID: 33395595
- WOS: WOS:000614697300003
- Find via

Supplementary
- Citations:
- Appears in Collections:
Article: Test-retest repeatability of T1rho (T1ρ) MR imaging in the head and neck
| Title | Test-retest repeatability of T1rho (T1ρ) MR imaging in the head and neck |
|---|---|
| Authors | |
| Keywords | head and neck quantitative MRI sequence T1rho imaging Test-retest repeatability |
| Issue Date | 2021 |
| Citation | European Journal of Radiology, 2021, v. 135, article no. 109489 How to Cite? |
| Abstract | Purpose: T1rho imaging is a new quantitative MRI sequence for head and neck cancer and the repeatability for this region is unknown. This study aimed to evaluate the repeatability of quantitative T1rho imaging in the head and neck. Materials and methods: T1rho imaging of the head and neck was prospectively performed in 15 healthy participants on three occasions. Scan 1 and 2 were performed with a time interval of 30 minutes (intra-session) and scan 3 was performed 14 days later (inter-session). T1rho values for normal tissues (parotid glands, palatine tonsils, pterygoid muscles, and tongue) were obtained on each scan. Intra-class coefficients (ICCs), within-subject coefficient of variances (wCoVs), and repeatability coefficient (RCs) of the intra-session scan (scan 1 vs 2) and inter-session scan (scan 1 vs 3) for the normal tissues were calculated. Results: The ICCs of T1rho values for normal tissues were almost perfect (0.83–0.97) for intra-session scans and were substantial (0.71–0.80) for inter-session scans. The wCoVs showed a small range (2.46%–3.30%) for intra-session scans, and slightly greater range (3.27%–6.51%) for inter-session scan. The greatest and lowest wCoVs of T1rho were found in the parotid gland and muscles, respectively. The T1rho RCs varied for all tissues between intra- and inter- sessions, and the greatest RC of 10.07 msec was observed for parotid gland on inter-session scan. Conclusion: T1rho imaging is a repeatable quantitative MRI sequence in the head and neck but variances of T1rho values among tissues should be take into account during analysis. |
| Persistent Identifier | http://hdl.handle.net/10722/353007 |
| ISSN | 2023 Impact Factor: 3.2 2023 SCImago Journal Rankings: 0.976 |
| ISI Accession Number ID |
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Ai, Qi Yong H. | - |
| dc.contributor.author | Zhang, Huimin | - |
| dc.contributor.author | Jiang, Baiyan | - |
| dc.contributor.author | So, Tiffany Y. | - |
| dc.contributor.author | Mo, Frankie K.F. | - |
| dc.contributor.author | Qamar, Sahrish | - |
| dc.contributor.author | Chen, Weitian | - |
| dc.contributor.author | King, Ann D. | - |
| dc.date.accessioned | 2025-01-13T03:01:34Z | - |
| dc.date.available | 2025-01-13T03:01:34Z | - |
| dc.date.issued | 2021 | - |
| dc.identifier.citation | European Journal of Radiology, 2021, v. 135, article no. 109489 | - |
| dc.identifier.issn | 0720-048X | - |
| dc.identifier.uri | http://hdl.handle.net/10722/353007 | - |
| dc.description.abstract | Purpose: T1rho imaging is a new quantitative MRI sequence for head and neck cancer and the repeatability for this region is unknown. This study aimed to evaluate the repeatability of quantitative T1rho imaging in the head and neck. Materials and methods: T1rho imaging of the head and neck was prospectively performed in 15 healthy participants on three occasions. Scan 1 and 2 were performed with a time interval of 30 minutes (intra-session) and scan 3 was performed 14 days later (inter-session). T1rho values for normal tissues (parotid glands, palatine tonsils, pterygoid muscles, and tongue) were obtained on each scan. Intra-class coefficients (ICCs), within-subject coefficient of variances (wCoVs), and repeatability coefficient (RCs) of the intra-session scan (scan 1 vs 2) and inter-session scan (scan 1 vs 3) for the normal tissues were calculated. Results: The ICCs of T1rho values for normal tissues were almost perfect (0.83–0.97) for intra-session scans and were substantial (0.71–0.80) for inter-session scans. The wCoVs showed a small range (2.46%–3.30%) for intra-session scans, and slightly greater range (3.27%–6.51%) for inter-session scan. The greatest and lowest wCoVs of T1rho were found in the parotid gland and muscles, respectively. The T1rho RCs varied for all tissues between intra- and inter- sessions, and the greatest RC of 10.07 msec was observed for parotid gland on inter-session scan. Conclusion: T1rho imaging is a repeatable quantitative MRI sequence in the head and neck but variances of T1rho values among tissues should be take into account during analysis. | - |
| dc.language | eng | - |
| dc.relation.ispartof | European Journal of Radiology | - |
| dc.subject | head and neck | - |
| dc.subject | quantitative MRI sequence | - |
| dc.subject | T1rho imaging | - |
| dc.subject | Test-retest repeatability | - |
| dc.title | Test-retest repeatability of T1rho (T1ρ) MR imaging in the head and neck | - |
| dc.type | Article | - |
| dc.description.nature | link_to_subscribed_fulltext | - |
| dc.identifier.doi | 10.1016/j.ejrad.2020.109489 | - |
| dc.identifier.pmid | 33395595 | - |
| dc.identifier.scopus | eid_2-s2.0-85098595464 | - |
| dc.identifier.volume | 135 | - |
| dc.identifier.spage | article no. 109489 | - |
| dc.identifier.epage | article no. 109489 | - |
| dc.identifier.eissn | 1872-7727 | - |
| dc.identifier.isi | WOS:000614697300003 | - |
