File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Preliminary study on the temperature relationship at remotely-sensed tree canopy and below-canopy air and ground surface

TitlePreliminary study on the temperature relationship at remotely-sensed tree canopy and below-canopy air and ground surface
Authors
KeywordsGround surface temperature
Human thermal comfort
Land surface temperature
Thermal infrared remote sensing
Tree canopy temperature
Issue Date2021
Citation
Building and Environment, 2021, v. 204, article no. 108169 How to Cite?
AbstractThermal infrared remote sensing is a popular tool to measure the impacts of land cover on land surface temperature (LST) in cities. Tree-covered areas usually exhibit a lower LST than other urban surfaces such as concrete, suggesting that urban trees can improve human thermal comfort. However, the remotely-sensed LST of trees is only representative of their canopy temperature. The linkage between the LST of trees and the below-canopy thermal conditions has not been investigated scientifically. This study aimed to measure the differences and determine the correlations between tree canopy temperature (Tc), below-canopy ground surface temperature (Ts) and below-canopy air temperature (Ta) from 42 trees of 16 species in a golf course in Hong Kong. Under the meteorological conditions of the study period (air temperature: ~26 °C; mean radiant temperature: ~30 °C), t-tests showed that mean ± SD Tc (24.1 ± 2.9 °C) did not significantly differ from Ts (24.5 ± 1.8 °C, p = 0.158), but it was significantly lower than Ta (25.4 ± 2.3 °C, p < 0.001). Tc was highly and significantly correlated with Ts (r = 0.81, p < 0.001) and Ta (r = 0.92, p < 0.001). Further analyses showed that the differences between Tc and Ts (ΔTcs) and between Tc and Ta (ΔTca) were significantly dependent on background air temperature (ΔTcs only), relative humidity, mean radiant temperature and incoming shortwave radiation. This study serves as a preliminary investigation on an important knowledge gap in urban climate research. The findings are particularly relevant to researchers who use remotely-sensed LST data to study human thermal comfort.
Persistent Identifierhttp://hdl.handle.net/10722/351593
ISSN
2023 Impact Factor: 7.1
2023 SCImago Journal Rankings: 1.647

 

DC FieldValueLanguage
dc.contributor.authorCheung, Pui Kwan-
dc.contributor.authorJim, C. Y.-
dc.contributor.authorHung, Pui Lam-
dc.date.accessioned2024-11-21T06:37:10Z-
dc.date.available2024-11-21T06:37:10Z-
dc.date.issued2021-
dc.identifier.citationBuilding and Environment, 2021, v. 204, article no. 108169-
dc.identifier.issn0360-1323-
dc.identifier.urihttp://hdl.handle.net/10722/351593-
dc.description.abstractThermal infrared remote sensing is a popular tool to measure the impacts of land cover on land surface temperature (LST) in cities. Tree-covered areas usually exhibit a lower LST than other urban surfaces such as concrete, suggesting that urban trees can improve human thermal comfort. However, the remotely-sensed LST of trees is only representative of their canopy temperature. The linkage between the LST of trees and the below-canopy thermal conditions has not been investigated scientifically. This study aimed to measure the differences and determine the correlations between tree canopy temperature (Tc), below-canopy ground surface temperature (Ts) and below-canopy air temperature (Ta) from 42 trees of 16 species in a golf course in Hong Kong. Under the meteorological conditions of the study period (air temperature: ~26 °C; mean radiant temperature: ~30 °C), t-tests showed that mean ± SD Tc (24.1 ± 2.9 °C) did not significantly differ from Ts (24.5 ± 1.8 °C, p = 0.158), but it was significantly lower than Ta (25.4 ± 2.3 °C, p < 0.001). Tc was highly and significantly correlated with Ts (r = 0.81, p < 0.001) and Ta (r = 0.92, p < 0.001). Further analyses showed that the differences between Tc and Ts (ΔTcs) and between Tc and Ta (ΔTca) were significantly dependent on background air temperature (ΔTcs only), relative humidity, mean radiant temperature and incoming shortwave radiation. This study serves as a preliminary investigation on an important knowledge gap in urban climate research. The findings are particularly relevant to researchers who use remotely-sensed LST data to study human thermal comfort.-
dc.languageeng-
dc.relation.ispartofBuilding and Environment-
dc.subjectGround surface temperature-
dc.subjectHuman thermal comfort-
dc.subjectLand surface temperature-
dc.subjectThermal infrared remote sensing-
dc.subjectTree canopy temperature-
dc.titlePreliminary study on the temperature relationship at remotely-sensed tree canopy and below-canopy air and ground surface-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/j.buildenv.2021.108169-
dc.identifier.scopuseid_2-s2.0-85111872691-
dc.identifier.volume204-
dc.identifier.spagearticle no. 108169-
dc.identifier.epagearticle no. 108169-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats