File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Development of novel low-cost gas recirculation system for the RPCs chambers

TitleDevelopment of novel low-cost gas recirculation system for the RPCs chambers
Authors
KeywordsGas system
Gaseous detectors
Resistive plate chambers
Issue Date25-Jan-2024
PublisherElsevier
Citation
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2024, v. 1061 How to Cite?
Abstract

An efficient and safe gas mixture recirculation system for Resistive Plate Chambers (RPCs) detector is a crucial item for planning any future application. The system is based on a special valve that decouples a suction pump from the RPC, with the aim to keep the pressure inside the chamber in the range from 1 mbar to 3 mbar, regardless of variations in atmospheric pressure, recirculated flow, and temperature. The circulating gas is flushed in pure water where the impurities developed inside the detector are expected to be soluble and trapped.


Persistent Identifierhttp://hdl.handle.net/10722/346455
ISSN
2023 Impact Factor: 1.5
2023 SCImago Journal Rankings: 0.514

 

DC FieldValueLanguage
dc.contributor.authorPastori, E-
dc.contributor.authorLiberti, B-
dc.contributor.authorAielli, G-
dc.contributor.authorCamarri, P-
dc.contributor.authorDi Ciaccio, A-
dc.contributor.authorCardarelli, R-
dc.contributor.authorDi Stante, L-
dc.contributor.authorPizzimento, L-
dc.contributor.authorProto, G-
dc.contributor.authorRocchi, A-
dc.contributor.authorSantonico, R-
dc.date.accessioned2024-09-17T00:30:42Z-
dc.date.available2024-09-17T00:30:42Z-
dc.date.issued2024-01-25-
dc.identifier.citationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2024, v. 1061-
dc.identifier.issn0168-9002-
dc.identifier.urihttp://hdl.handle.net/10722/346455-
dc.description.abstract<p>An efficient and safe gas mixture recirculation system for Resistive Plate Chambers (RPCs) detector is a crucial item for planning any future application. The system is based on a special valve that decouples a suction pump from the RPC, with the aim to keep the pressure inside the chamber in the range from 1 mbar to 3 mbar, regardless of variations in atmospheric pressure, recirculated flow, and temperature. The circulating gas is flushed in pure water where the impurities developed inside the detector are expected to be soluble and trapped.</p>-
dc.languageeng-
dc.publisherElsevier-
dc.relation.ispartofNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment-
dc.subjectGas system-
dc.subjectGaseous detectors-
dc.subjectResistive plate chambers-
dc.titleDevelopment of novel low-cost gas recirculation system for the RPCs chambers-
dc.typeArticle-
dc.identifier.doi10.1016/j.nima.2024.169133-
dc.identifier.scopuseid_2-s2.0-85183951165-
dc.identifier.volume1061-
dc.identifier.eissn1872-9576-
dc.identifier.issnl0168-9002-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats