File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Custom Made Candy Plug for Distal False Lumen Occlusion in Aortic Dissection: International Experience

TitleCustom Made Candy Plug for Distal False Lumen Occlusion in Aortic Dissection: International Experience
Authors
KeywordsAneurysm
Aortic dissection
Aortic remodelling
Endovascular repair
False lumen occlusion
Thoracic endovascular aortic repair
Issue Date21-Mar-2023
PublisherElsevier
Citation
European Journal of Vascular and Endovascular Surgery, 2023, v. 66, n. 1, p. 50-56 How to Cite?
Abstract

Objective: To evaluate early and midterm outcomes of the Candy Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair for aortic dissection (AD) in a more real world cohort of patients from an international multicentre registry. Methods: A multicentre retrospective study was conducted of all consecutive patients from the contributing centres with subacute and chronic AD treated with the CP technique from October 2013 to April 2020 at 18 centres. Results: A custom made CP was used in 155 patients (92 males, mean age 62 ± 11 years). Fourteen (9%) presented with ruptured false lumen aneurysms. Technical success was achieved in all patients (100%). Clinical success was achieved in 138 patients (89%). The median hospital stay was 7 days (1 – 77). The 30 day mortality rate was 3% (n = 5). Stroke occurred in four patients (3%). Spinal cord ischaemia occurred in three patients (2%). The 30 day computed tomography angiogram (CTA) confirmed successful CP placement at the intended level in all patients. Early complete FL occlusion was achieved in 120 patients (77%). Early (30 day) CP related re-intervention was required in four patients (3%). The early (30 day) stent graft related re-intervention rate was 8% (n = 12). Follow up CTA was available in 142 patients (92%), with a median follow up of 23 months (6 – 87). Aneurysmal regression was achieved in 68 of 142 patients (47%); the aneurysm diameter remained stable in 69 of 142 patients (49%) and increased in five of 142 patients (4%). A higher rate of early FL occlusion was detected in the largest volume centre patients (50 [88%] vs. 70 [71%] from other centres; p = .019). No other differences in outcome were identified regarding volume of cases or learning curve. Conclusion: This international CP technique experience confirmed its feasibility and low mortality and morbidity rates. Aortic remodelling and false lumen thrombosis rates were high and support the concept of distal FL occlusion in AD using the CP technique.


Persistent Identifierhttp://hdl.handle.net/10722/345755
ISSN
2023 Impact Factor: 5.7
2023 SCImago Journal Rankings: 1.330

 

DC FieldValueLanguage
dc.contributor.authorEleshra, Ahmed-
dc.contributor.authorHaulon, Stephan-
dc.contributor.authorBertoglio, Luca-
dc.contributor.authorLindsay, Thomas-
dc.contributor.authorRohlffs, Fiona-
dc.contributor.authorDias, Nuno-
dc.contributor.authorTsilimparis, Nikolaos-
dc.contributor.authorPanuccio, Giuseppe-
dc.contributor.authorKölbel, Tilo-
dc.contributor.authorMougin, Justine-
dc.contributor.authorChiesa, Roberto-
dc.contributor.authorSalvati, Simone-
dc.contributor.authorNyman, Johan-
dc.contributor.authorSonesson, Björn-
dc.contributor.authorReeps, Christian-
dc.contributor.authorLutz, Brigitta-
dc.contributor.authorTrimarchi, Santi-
dc.contributor.authorLomazzi, Chiara-
dc.contributor.authorSobocinski, Jonothan-
dc.contributor.authorKerezsy, Michael-
dc.contributor.authorvan Rijswijk, Catharina SP-
dc.contributor.authorvan Schaik, J-
dc.contributor.authorPfister, Karin-
dc.contributor.authorMialhe, Claude-
dc.contributor.authorTielliu, Ignace-
dc.contributor.authorModarai, Bijan-
dc.contributor.authorFlorek, Hans Joachim-
dc.contributor.authorJakimowicz, Tomasz-
dc.contributor.authorCheng, Stephen-
dc.date.accessioned2024-08-28T07:40:29Z-
dc.date.available2024-08-28T07:40:29Z-
dc.date.issued2023-03-21-
dc.identifier.citationEuropean Journal of Vascular and Endovascular Surgery, 2023, v. 66, n. 1, p. 50-56-
dc.identifier.issn1078-5884-
dc.identifier.urihttp://hdl.handle.net/10722/345755-
dc.description.abstract<p>Objective: To evaluate early and midterm outcomes of the Candy Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair for aortic dissection (AD) in a more real world cohort of patients from an international multicentre registry. Methods: A multicentre retrospective study was conducted of all consecutive patients from the contributing centres with subacute and chronic AD treated with the CP technique from October 2013 to April 2020 at 18 centres. Results: A custom made CP was used in 155 patients (92 males, mean age 62 ± 11 years). Fourteen (9%) presented with ruptured false lumen aneurysms. Technical success was achieved in all patients (100%). Clinical success was achieved in 138 patients (89%). The median hospital stay was 7 days (1 – 77). The 30 day mortality rate was 3% (n = 5). Stroke occurred in four patients (3%). Spinal cord ischaemia occurred in three patients (2%). The 30 day computed tomography angiogram (CTA) confirmed successful CP placement at the intended level in all patients. Early complete FL occlusion was achieved in 120 patients (77%). Early (30 day) CP related re-intervention was required in four patients (3%). The early (30 day) stent graft related re-intervention rate was 8% (n = 12). Follow up CTA was available in 142 patients (92%), with a median follow up of 23 months (6 – 87). Aneurysmal regression was achieved in 68 of 142 patients (47%); the aneurysm diameter remained stable in 69 of 142 patients (49%) and increased in five of 142 patients (4%). A higher rate of early FL occlusion was detected in the largest volume centre patients (50 [88%] vs. 70 [71%] from other centres; p = .019). No other differences in outcome were identified regarding volume of cases or learning curve. Conclusion: This international CP technique experience confirmed its feasibility and low mortality and morbidity rates. Aortic remodelling and false lumen thrombosis rates were high and support the concept of distal FL occlusion in AD using the CP technique.</p>-
dc.languageeng-
dc.publisherElsevier-
dc.relation.ispartofEuropean Journal of Vascular and Endovascular Surgery-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.subjectAneurysm-
dc.subjectAortic dissection-
dc.subjectAortic remodelling-
dc.subjectEndovascular repair-
dc.subjectFalse lumen occlusion-
dc.subjectThoracic endovascular aortic repair-
dc.titleCustom Made Candy Plug for Distal False Lumen Occlusion in Aortic Dissection: International Experience-
dc.typeArticle-
dc.identifier.doi10.1016/j.ejvs.2023.03.020-
dc.identifier.pmid36958480-
dc.identifier.scopuseid_2-s2.0-85159061361-
dc.identifier.volume66-
dc.identifier.issue1-
dc.identifier.spage50-
dc.identifier.epage56-
dc.identifier.eissn1532-2165-
dc.identifier.issnl1078-5884-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats