File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.asjsur.2015.05.002
- Scopus: eid_2-s2.0-84937716769
- PMID: 26216258
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Development and evaluation of a new biodegradable vena cava filter in a canine model
Title | Development and evaluation of a new biodegradable vena cava filter in a canine model |
---|---|
Authors | |
Keywords | biodegradable deep venous thrombosis pulmonary embolism vena cava filter |
Issue Date | 2017 |
Citation | Asian Journal of Surgery, 2017, v. 40, n. 1, p. 12-16 How to Cite? |
Abstract | Purpose Preliminary testing of a new biodegradable inferior vena cava filter in a canine model. Methods The biodegradable filter consisted of two parts, a filter cone and a stent. The filter cone was constructed of six polyglycolic acid polymer strands anchored to a handmade absorbable stent. Central inferior vena cava fixation was accomplished by the absorbable stent, which was made of polycaprolactone. Device insertion was performed through a 9F sheath under ultrasound guidance on 10 adult beagles. The filters were operatively retrieved at 6 weeks after implantation. The inferior venae cavae were subsequently analyzed grossly and using light microscopy. Results None of the 10 beagles had abnormal vital signs. All of the 10 filters migrated cephalad approximately <2 cm and remained below the renal vein ostia. One specimen had evidence of incorporated residual strands within the caval wall on gross examination. The caval wall became thickened at the level of filter placement without significant lumen narrowing. There was no evidence of pulmonary embolism caused by degradation products of the absorbable strands. Conclusion Biodegradable inferior vena cava filters are feasible and potentially could be used in specific patients who are at temporary high risk of venous thromboembolism. |
Persistent Identifier | http://hdl.handle.net/10722/345077 |
ISSN | 2023 Impact Factor: 3.5 2023 SCImago Journal Rankings: 0.538 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zhang, Fuxian | - |
dc.contributor.author | Li, Hailei | - |
dc.contributor.author | Liang, Gangzhu | - |
dc.contributor.author | Zhang, Huan | - |
dc.date.accessioned | 2024-08-15T09:25:05Z | - |
dc.date.available | 2024-08-15T09:25:05Z | - |
dc.date.issued | 2017 | - |
dc.identifier.citation | Asian Journal of Surgery, 2017, v. 40, n. 1, p. 12-16 | - |
dc.identifier.issn | 1015-9584 | - |
dc.identifier.uri | http://hdl.handle.net/10722/345077 | - |
dc.description.abstract | Purpose Preliminary testing of a new biodegradable inferior vena cava filter in a canine model. Methods The biodegradable filter consisted of two parts, a filter cone and a stent. The filter cone was constructed of six polyglycolic acid polymer strands anchored to a handmade absorbable stent. Central inferior vena cava fixation was accomplished by the absorbable stent, which was made of polycaprolactone. Device insertion was performed through a 9F sheath under ultrasound guidance on 10 adult beagles. The filters were operatively retrieved at 6 weeks after implantation. The inferior venae cavae were subsequently analyzed grossly and using light microscopy. Results None of the 10 beagles had abnormal vital signs. All of the 10 filters migrated cephalad approximately <2 cm and remained below the renal vein ostia. One specimen had evidence of incorporated residual strands within the caval wall on gross examination. The caval wall became thickened at the level of filter placement without significant lumen narrowing. There was no evidence of pulmonary embolism caused by degradation products of the absorbable strands. Conclusion Biodegradable inferior vena cava filters are feasible and potentially could be used in specific patients who are at temporary high risk of venous thromboembolism. | - |
dc.language | eng | - |
dc.relation.ispartof | Asian Journal of Surgery | - |
dc.subject | biodegradable | - |
dc.subject | deep venous thrombosis | - |
dc.subject | pulmonary embolism | - |
dc.subject | vena cava filter | - |
dc.title | Development and evaluation of a new biodegradable vena cava filter in a canine model | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/j.asjsur.2015.05.002 | - |
dc.identifier.pmid | 26216258 | - |
dc.identifier.scopus | eid_2-s2.0-84937716769 | - |
dc.identifier.volume | 40 | - |
dc.identifier.issue | 1 | - |
dc.identifier.spage | 12 | - |
dc.identifier.epage | 16 | - |
dc.identifier.eissn | 0219-3108 | - |