Article: A Tandem Mass Spectrometry Acquisition Strategy Based on Exclusion of Precursor Ions
Title | A Tandem Mass Spectrometry Acquisition Strategy Based on Exclusion of Precursor Ions |
---|---|
Authors | |
Keywords | Liquid chromatography-electrospray ionization mass spectrometry/mass spectrometry Precursor ion exclusion list Tandem mass spectrometry acquisition |
Issue Date | 2010 |
Citation | Chinese Journal of Analytical Chemistry, 2010, v. 38, n. 2, p. 241-244 How to Cite? |
Abstract | Because of the complexity of proteome samples, comprehensive analysis to characterize all proteins is still not possible with present methodologies. It has been shown that replicate runs could increase the number of identified proteins. However, the redundancy of protein identifications was high. High-abundance peptides tended to be repeatedly analyzed in different runs. To reduce the redundancy and improve the efficiency of identification, the tandem mass spectrometry (MS/MS) acquisition method of linear ion trap-Fourier transform ion cyclotron resonance mass spectrometry was studied, and an acquisition strategy based on exclusion of precursor ions was developed. It proved that the strategy could extremely reduce the redundancy of MS/MS acquisition and improve the efficiency of protein identifications. |
Persistent Identifier | http://hdl.handle.net/10722/342610 |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | MI, Wei | - |
dc.contributor.author | WANG, Jing | - |
dc.contributor.author | YING, Wan Tao | - |
dc.contributor.author | JIA, Wei | - |
dc.contributor.author | CAI, Yun | - |
dc.contributor.author | QIAN, Xiao Hong | - |
dc.date.accessioned | 2024-04-17T07:05:01Z | - |
dc.date.available | 2024-04-17T07:05:01Z | - |
dc.date.issued | 2010 | - |
dc.identifier.citation | Chinese Journal of Analytical Chemistry, 2010, v. 38, n. 2, p. 241-244 | - |
dc.identifier.uri | http://hdl.handle.net/10722/342610 | - |
dc.description.abstract | Because of the complexity of proteome samples, comprehensive analysis to characterize all proteins is still not possible with present methodologies. It has been shown that replicate runs could increase the number of identified proteins. However, the redundancy of protein identifications was high. High-abundance peptides tended to be repeatedly analyzed in different runs. To reduce the redundancy and improve the efficiency of identification, the tandem mass spectrometry (MS/MS) acquisition method of linear ion trap-Fourier transform ion cyclotron resonance mass spectrometry was studied, and an acquisition strategy based on exclusion of precursor ions was developed. It proved that the strategy could extremely reduce the redundancy of MS/MS acquisition and improve the efficiency of protein identifications. | - |
dc.language | eng | - |
dc.relation.ispartof | Chinese Journal of Analytical Chemistry | - |
dc.subject | Liquid chromatography-electrospray ionization mass spectrometry/mass spectrometry | - |
dc.subject | Precursor ion exclusion list | - |
dc.subject | Tandem mass spectrometry acquisition | - |
dc.title | A Tandem Mass Spectrometry Acquisition Strategy Based on Exclusion of Precursor Ions | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/S1872-2040(09)60025-6 | - |
dc.identifier.scopus | eid_2-s2.0-85097092902 | - |
dc.identifier.volume | 38 | - |
dc.identifier.issue | 2 | - |
dc.identifier.spage | 241 | - |
dc.identifier.epage | 244 | - |
dc.identifier.eissn | 1872-2040 | - |