File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/S1872-2040(08)60053-5
- Scopus: eid_2-s2.0-51249084788
- WOS: WOS:000260136800002
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Quantitative Phosphoproteomics Methods Based on Isoelectric Focusing and 18O Labeling Method
Title | Quantitative Phosphoproteomics Methods Based on Isoelectric Focusing and <sup>18</sup>O Labeling Method |
---|---|
Authors | |
Keywords | 18 O labeling method Isoelectric focusing Linear ion trap Fourier transform ion cyclotron resonance mass spectrometry (LTQ-FTICR-MS) Qualitative and quantitative phosphoproteomics |
Issue Date | 2008 |
Citation | Chinese Journal of Analytical Chemistry, 2008, v. 36, n. 8, p. 1017-1023 How to Cite? |
Abstract | For the analysis of quantitative phosphoproteomics, both qualitative and quantitative strategies are needed to be studied. Therefore, 18O labeling method was used to label the tryptic phosphopeptides in this study. The labeling condition including the labeling time and the inactivation of the trypsin after labeled were optimized. The experimental results indicated that the incorporation of oxygen-18 isotopes for almost all peptides but the C-terminal peptides not ending on a lysine or an arginine could drive to 100% with tryptic catalyzing in the KH2PO4 buffer system (pH 4-5) for 19-24 h at 37 °C. And tris(2-carboxyethyl)-phosphine chosen as the inactivation of trypsin could effectively inhibit the exchange of incorporated oxygen-18 isotopes with oxygen-16 isotopes. Then, the phosphopeptides enrichment technology IPG-IEF was built, 491 phosphosites, 362 phosphopeptides, and 356 phosphoproteins were identified from HepG2 cells. This suggested that IPG-IEF was effective in the phosphopeptides enrichment analysis on a large scale and could be well compatible with 18O labeling method. Finally, combining with LTQ-FTICR mass spectrometry, 18O-IPG-IEF-LTQ-FTICR was built and demonstrated to be effective in qualitative and quantitative phosphoproteomics study by the experiment results. This study provided useful technology for quantitative phosphoproteome. © 2008 Changchun Institute of Applied Chemistry, Chinese Academy of Sciences. |
Persistent Identifier | http://hdl.handle.net/10722/342333 |
ISSN | 2023 Impact Factor: 1.2 2023 SCImago Journal Rankings: 0.355 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | SUI, Shao Hui | - |
dc.contributor.author | WANG, Jing Lan | - |
dc.contributor.author | JIA, Wei | - |
dc.contributor.author | LU, Zhuang | - |
dc.contributor.author | LIU, Jin Feng | - |
dc.contributor.author | SONG, Li Na | - |
dc.contributor.author | CAI, Yun | - |
dc.contributor.author | QIAN, Xiao Hong | - |
dc.date.accessioned | 2024-04-17T07:03:02Z | - |
dc.date.available | 2024-04-17T07:03:02Z | - |
dc.date.issued | 2008 | - |
dc.identifier.citation | Chinese Journal of Analytical Chemistry, 2008, v. 36, n. 8, p. 1017-1023 | - |
dc.identifier.issn | 0253-3820 | - |
dc.identifier.uri | http://hdl.handle.net/10722/342333 | - |
dc.description.abstract | For the analysis of quantitative phosphoproteomics, both qualitative and quantitative strategies are needed to be studied. Therefore, 18O labeling method was used to label the tryptic phosphopeptides in this study. The labeling condition including the labeling time and the inactivation of the trypsin after labeled were optimized. The experimental results indicated that the incorporation of oxygen-18 isotopes for almost all peptides but the C-terminal peptides not ending on a lysine or an arginine could drive to 100% with tryptic catalyzing in the KH2PO4 buffer system (pH 4-5) for 19-24 h at 37 °C. And tris(2-carboxyethyl)-phosphine chosen as the inactivation of trypsin could effectively inhibit the exchange of incorporated oxygen-18 isotopes with oxygen-16 isotopes. Then, the phosphopeptides enrichment technology IPG-IEF was built, 491 phosphosites, 362 phosphopeptides, and 356 phosphoproteins were identified from HepG2 cells. This suggested that IPG-IEF was effective in the phosphopeptides enrichment analysis on a large scale and could be well compatible with 18O labeling method. Finally, combining with LTQ-FTICR mass spectrometry, 18O-IPG-IEF-LTQ-FTICR was built and demonstrated to be effective in qualitative and quantitative phosphoproteomics study by the experiment results. This study provided useful technology for quantitative phosphoproteome. © 2008 Changchun Institute of Applied Chemistry, Chinese Academy of Sciences. | - |
dc.language | eng | - |
dc.relation.ispartof | Chinese Journal of Analytical Chemistry | - |
dc.subject | 18 O labeling method | - |
dc.subject | Isoelectric focusing | - |
dc.subject | Linear ion trap Fourier transform ion cyclotron resonance mass spectrometry (LTQ-FTICR-MS) | - |
dc.subject | Qualitative and quantitative phosphoproteomics | - |
dc.title | Quantitative Phosphoproteomics Methods Based on Isoelectric Focusing and <sup>18</sup>O Labeling Method | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/S1872-2040(08)60053-5 | - |
dc.identifier.scopus | eid_2-s2.0-51249084788 | - |
dc.identifier.volume | 36 | - |
dc.identifier.issue | 8 | - |
dc.identifier.spage | 1017 | - |
dc.identifier.epage | 1023 | - |
dc.identifier.eissn | 1872-2040 | - |
dc.identifier.isi | WOS:000260136800002 | - |