TitleCross modality generative learning framework for anatomical transitive Magnetic Resonance Imaging (MRI) from Electrical Impedance Tomography (EIT) image
Authors
KeywordsElectrical Impedance Tomography
Generative networks
Magnetic Resonance Image
Medical images
Issue Date1-Sep-2023
PublisherElsevier
Citation
Computerized Medical Imaging and Graphics, 2023, v. 108 How to Cite?
Abstract

This paper presents a cross-modality generative learning framework for transitive magnetic resonance imaging (MRI) from electrical impedance tomography (EIT). The proposed framework is aimed at converting low-resolution EIT images to high-resolution wrist MRI images using a cascaded cycle generative adversarial network (CycleGAN) model. This model comprises three main components: the collection of initial EIT from the medical device, the generation of a high-resolution transitive EIT image from the corresponding MRI image for domain adaptation, and the coalescence of two CycleGAN models for cross-modality generation. The initial EIT image was generated at three different frequencies (70 kHz, 140 kHz, and 200 kHz) using a 16-electrode belt. Wrist T1-weighted images were acquired on a 1.5T MRI. A total of 19 normal volunteers were imaged using both EIT and MRI, which resulted in 713 paired EIT and MRI images. The cascaded CycleGAN, end-to-end CycleGAN, and Pix2Pix models were trained and tested on the same cohort. The proposed method achieved the highest accuracy in bone detection, with 0.97 for the proposed cascaded CycleGAN, 0.68 for end-to-end CycleGAN, and 0.70 for the Pix2Pix model. Visual inspection showed that the proposed method reduced bone-related errors in the MRI-style anatomical reference compared with end-to-end CycleGAN and Pix2Pix. Multifrequency EIT inputs reduced the testing normalized root mean squared error of MRI-style anatomical reference from 67.9% ± 12.7% to 61.4% ± 8.8% compared with that of single-frequency EIT. The mean conductivity values of fat and bone from regularized EIT were 0.0435 ± 0.0379 S/m and 0.0183 ± 0.0154 S/m, respectively, when the anatomical prior was employed. These results demonstrate that the proposed framework is able to generate MRI-style anatomical references from EIT images with a good degree of accuracy.


Persistent Identifierhttp://hdl.handle.net/10722/338208
ISSN
2021 Impact Factor: 7.422
2020 SCImago Journal Rankings: 1.033

 

DC FieldValueLanguage
dc.contributor.authorWang, ZJ-
dc.contributor.authorNawaz, M-
dc.contributor.authorKhan, S-
dc.contributor.authorXia, P-
dc.contributor.authorIrfan, M-
dc.contributor.authorWong, EC-
dc.contributor.authorChan, RS-
dc.contributor.authorCao, P-
dc.date.accessioned2024-03-11T10:27:04Z-
dc.date.available2024-03-11T10:27:04Z-
dc.date.issued2023-09-01-
dc.identifier.citationComputerized Medical Imaging and Graphics, 2023, v. 108-
dc.identifier.issn0895-6111-
dc.identifier.urihttp://hdl.handle.net/10722/338208-
dc.description.abstract<p>This paper presents a cross-modality generative learning framework for transitive magnetic resonance imaging (MRI) from <a href="https://www.sciencedirect.com/topics/medicine-and-dentistry/electrical-impedance-tomography" title="Learn more about electrical impedance tomography from ScienceDirect's AI-generated Topic Pages">electrical impedance tomography</a> (EIT). The proposed framework is aimed at converting low-resolution EIT images to high-resolution wrist MRI images using a cascaded cycle <a href="https://www.sciencedirect.com/topics/computer-science/generative-adversarial-networks" title="Learn more about generative adversarial network from ScienceDirect's AI-generated Topic Pages">generative adversarial network</a> (CycleGAN) model. This model comprises three main components: the collection of initial EIT from the <a href="https://www.sciencedirect.com/topics/medicine-and-dentistry/medical-device" title="Learn more about medical device from ScienceDirect's AI-generated Topic Pages">medical device</a>, the generation of a high-resolution transitive EIT image from the corresponding MRI image for <a href="https://www.sciencedirect.com/topics/computer-science/domain-adaptation" title="Learn more about domain adaptation from ScienceDirect's AI-generated Topic Pages">domain adaptation</a>, and the coalescence of two CycleGAN models for cross-modality generation. The initial EIT image was generated at three different frequencies (70 kHz, 140 kHz, and 200 kHz) using a 16-electrode belt. Wrist T1-weighted images were acquired on a 1.5T MRI. A total of 19 normal volunteers were imaged using both EIT and MRI, which resulted in 713 paired EIT and MRI images. The cascaded CycleGAN, end-to-end CycleGAN, and Pix2Pix models were trained and tested on the same cohort. The proposed method achieved the highest accuracy in bone detection, with 0.97 for the proposed cascaded CycleGAN, 0.68 for end-to-end CycleGAN, and 0.70 for the Pix2Pix model. Visual inspection showed that the proposed method reduced bone-related errors in the MRI-style anatomical reference compared with end-to-end CycleGAN and Pix2Pix. Multifrequency EIT inputs reduced the testing normalized root mean squared error of MRI-style anatomical reference from 67.9% ± 12.7% to 61.4% ± 8.8% compared with that of single-frequency EIT. The mean conductivity values of fat and bone from regularized EIT were 0.0435 ± 0.0379 S/m and 0.0183 ± 0.0154 S/m, respectively, when the anatomical prior was employed. These results demonstrate that the proposed framework is able to generate MRI-style anatomical references from EIT images with a good degree of accuracy.</p>-
dc.languageeng-
dc.publisherElsevier-
dc.relation.ispartofComputerized Medical Imaging and Graphics-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.subjectElectrical Impedance Tomography-
dc.subjectGenerative networks-
dc.subjectMagnetic Resonance Image-
dc.subjectMedical images-
dc.titleCross modality generative learning framework for anatomical transitive Magnetic Resonance Imaging (MRI) from Electrical Impedance Tomography (EIT) image-
dc.typeArticle-
dc.identifier.doi10.1016/j.compmedimag.2023.102272-
dc.identifier.scopuseid_2-s2.0-85166386056-
dc.identifier.volume108-
dc.identifier.eissn1879-0771-
dc.identifier.issnl0895-6111-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats