Article: Cross modality generative learning framework for anatomical transitive Magnetic Resonance Imaging (MRI) from Electrical Impedance Tomography (EIT) image
Title | Cross modality generative learning framework for anatomical transitive Magnetic Resonance Imaging (MRI) from Electrical Impedance Tomography (EIT) image |
---|---|
Authors | |
Keywords | Electrical Impedance Tomography Generative networks Magnetic Resonance Image Medical images |
Issue Date | 1-Sep-2023 |
Publisher | Elsevier |
Citation | Computerized Medical Imaging and Graphics, 2023, v. 108 How to Cite? |
Abstract | This paper presents a cross-modality generative learning framework for transitive magnetic resonance imaging (MRI) from electrical impedance tomography (EIT). The proposed framework is aimed at converting low-resolution EIT images to high-resolution wrist MRI images using a cascaded cycle generative adversarial network (CycleGAN) model. This model comprises three main components: the collection of initial EIT from the medical device, the generation of a high-resolution transitive EIT image from the corresponding MRI image for domain adaptation, and the coalescence of two CycleGAN models for cross-modality generation. The initial EIT image was generated at three different frequencies (70 kHz, 140 kHz, and 200 kHz) using a 16-electrode belt. Wrist T1-weighted images were acquired on a 1.5T MRI. A total of 19 normal volunteers were imaged using both EIT and MRI, which resulted in 713 paired EIT and MRI images. The cascaded CycleGAN, end-to-end CycleGAN, and Pix2Pix models were trained and tested on the same cohort. The proposed method achieved the highest accuracy in bone detection, with 0.97 for the proposed cascaded CycleGAN, 0.68 for end-to-end CycleGAN, and 0.70 for the Pix2Pix model. Visual inspection showed that the proposed method reduced bone-related errors in the MRI-style anatomical reference compared with end-to-end CycleGAN and Pix2Pix. Multifrequency EIT inputs reduced the testing normalized root mean squared error of MRI-style anatomical reference from 67.9% ± 12.7% to 61.4% ± 8.8% compared with that of single-frequency EIT. The mean conductivity values of fat and bone from regularized EIT were 0.0435 ± 0.0379 S/m and 0.0183 ± 0.0154 S/m, respectively, when the anatomical prior was employed. These results demonstrate that the proposed framework is able to generate MRI-style anatomical references from EIT images with a good degree of accuracy. |
Persistent Identifier | http://hdl.handle.net/10722/338208 |
ISSN | 2023 Impact Factor: 5.4 2023 SCImago Journal Rankings: 1.459 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Wang, ZJ | - |
dc.contributor.author | Nawaz, M | - |
dc.contributor.author | Khan, S | - |
dc.contributor.author | Xia, P | - |
dc.contributor.author | Irfan, M | - |
dc.contributor.author | Wong, EC | - |
dc.contributor.author | Chan, RS | - |
dc.contributor.author | Cao, P | - |
dc.date.accessioned | 2024-03-11T10:27:04Z | - |
dc.date.available | 2024-03-11T10:27:04Z | - |
dc.date.issued | 2023-09-01 | - |
dc.identifier.citation | Computerized Medical Imaging and Graphics, 2023, v. 108 | - |
dc.identifier.issn | 0895-6111 | - |
dc.identifier.uri | http://hdl.handle.net/10722/338208 | - |
dc.description.abstract | <p>This paper presents a cross-modality generative learning framework for transitive magnetic resonance imaging (MRI) from <a href="https://www.sciencedirect.com/topics/medicine-and-dentistry/electrical-impedance-tomography" title="Learn more about electrical impedance tomography from ScienceDirect's AI-generated Topic Pages">electrical impedance tomography</a> (EIT). The proposed framework is aimed at converting low-resolution EIT images to high-resolution wrist MRI images using a cascaded cycle <a href="https://www.sciencedirect.com/topics/computer-science/generative-adversarial-networks" title="Learn more about generative adversarial network from ScienceDirect's AI-generated Topic Pages">generative adversarial network</a> (CycleGAN) model. This model comprises three main components: the collection of initial EIT from the <a href="https://www.sciencedirect.com/topics/medicine-and-dentistry/medical-device" title="Learn more about medical device from ScienceDirect's AI-generated Topic Pages">medical device</a>, the generation of a high-resolution transitive EIT image from the corresponding MRI image for <a href="https://www.sciencedirect.com/topics/computer-science/domain-adaptation" title="Learn more about domain adaptation from ScienceDirect's AI-generated Topic Pages">domain adaptation</a>, and the coalescence of two CycleGAN models for cross-modality generation. The initial EIT image was generated at three different frequencies (70 kHz, 140 kHz, and 200 kHz) using a 16-electrode belt. Wrist T1-weighted images were acquired on a 1.5T MRI. A total of 19 normal volunteers were imaged using both EIT and MRI, which resulted in 713 paired EIT and MRI images. The cascaded CycleGAN, end-to-end CycleGAN, and Pix2Pix models were trained and tested on the same cohort. The proposed method achieved the highest accuracy in bone detection, with 0.97 for the proposed cascaded CycleGAN, 0.68 for end-to-end CycleGAN, and 0.70 for the Pix2Pix model. Visual inspection showed that the proposed method reduced bone-related errors in the MRI-style anatomical reference compared with end-to-end CycleGAN and Pix2Pix. Multifrequency EIT inputs reduced the testing normalized root mean squared error of MRI-style anatomical reference from 67.9% ± 12.7% to 61.4% ± 8.8% compared with that of single-frequency EIT. The mean conductivity values of fat and bone from regularized EIT were 0.0435 ± 0.0379 S/m and 0.0183 ± 0.0154 S/m, respectively, when the anatomical prior was employed. These results demonstrate that the proposed framework is able to generate MRI-style anatomical references from EIT images with a good degree of accuracy.</p> | - |
dc.language | eng | - |
dc.publisher | Elsevier | - |
dc.relation.ispartof | Computerized Medical Imaging and Graphics | - |
dc.rights | This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. | - |
dc.subject | Electrical Impedance Tomography | - |
dc.subject | Generative networks | - |
dc.subject | Magnetic Resonance Image | - |
dc.subject | Medical images | - |
dc.title | Cross modality generative learning framework for anatomical transitive Magnetic Resonance Imaging (MRI) from Electrical Impedance Tomography (EIT) image | - |
dc.type | Article | - |
dc.identifier.doi | 10.1016/j.compmedimag.2023.102272 | - |
dc.identifier.scopus | eid_2-s2.0-85166386056 | - |
dc.identifier.volume | 108 | - |
dc.identifier.eissn | 1879-0771 | - |
dc.identifier.isi | WOS:001047101000001 | - |
dc.identifier.issnl | 0895-6111 | - |