File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Noncontact photoacoustic lipid imaging by remote sensing on first overtone of the C-H bond

TitleNoncontact photoacoustic lipid imaging by remote sensing on first overtone of the C-H bond
Authors
Issue Date28-Mar-2023
Citation
Advanced Photonics Nexus, 2023, v. 2, n. 2 How to Cite?
Abstract

Lipid imaging by conventional photoacoustic microscopy subjects to direct contact sensing with relatively low detection bandwidth and sensitivity, which induces superficial imaging depth and low signal-to-noise ratio (SNR) in practical imaging scenarios. Herein, we present a photoacoustic remote sensing microscopy for lipid distribution mapping in bio-tissue, featuring noncontact implementation, broad detection bandwidth, deep penetration depth, and high SNR. A tailored high-energy pulsed laser source with a spectrum centered at 1750 nm is used as the excitation beam, while a cofocused 1550 nm continuous-wave beam is used as the probe signal. The pump wavelength is selected to overlap the first overtone of the C-H bond in response to the intensive absorption of lipid molecules, which introduces a much-enhanced SNR (55 dB) onto photoacoustic remote sensing (PARS) signals. Meanwhile, the optical sensing scheme of the photoacoustic signals provides broadband detection compared to the acoustic transducer and refrains the bio-samples from direct contact operations by eliminating the ultrasonic coupling medium. Taking merits of the high detection sensitivity, deep penetration depth, broadband detection, and high resolution of the PARS system, high-quality tissue scale lipid imaging is demonstrated in a model organism and brain slice.


Persistent Identifierhttp://hdl.handle.net/10722/331565
ISSN

 

DC FieldValueLanguage
dc.contributor.authorHu, Guyue-
dc.contributor.authorRan, Qiao-
dc.contributor.authorSo, Beth Wing Lam-
dc.contributor.authorLi, Mingsheng-
dc.contributor.authorShi, Jiawei-
dc.contributor.authorDong, Xin-
dc.contributor.authorKang, Jiqiang-
dc.contributor.authorWong, Kenneth-
dc.date.accessioned2023-09-21T06:56:58Z-
dc.date.available2023-09-21T06:56:58Z-
dc.date.issued2023-03-28-
dc.identifier.citationAdvanced Photonics Nexus, 2023, v. 2, n. 2-
dc.identifier.issn2791-1519-
dc.identifier.urihttp://hdl.handle.net/10722/331565-
dc.description.abstract<table><thead><tr><td><p>Lipid imaging by conventional photoacoustic microscopy subjects to direct contact sensing with relatively low detection bandwidth and sensitivity, which induces superficial imaging depth and low signal-to-noise ratio (SNR) in practical imaging scenarios. Herein, we present a photoacoustic remote sensing microscopy for lipid distribution mapping in bio-tissue, featuring noncontact implementation, broad detection bandwidth, deep penetration depth, and high SNR. A tailored high-energy pulsed laser source with a spectrum centered at 1750 nm is used as the excitation beam, while a cofocused 1550 nm continuous-wave beam is used as the probe signal. The pump wavelength is selected to overlap the first overtone of the C-H bond in response to the intensive absorption of lipid molecules, which introduces a much-enhanced SNR (55 dB) onto photoacoustic remote sensing (PARS) signals. Meanwhile, the optical sensing scheme of the photoacoustic signals provides broadband detection compared to the acoustic transducer and refrains the bio-samples from direct contact operations by eliminating the ultrasonic coupling medium. Taking merits of the high detection sensitivity, deep penetration depth, broadband detection, and high resolution of the PARS system, high-quality tissue scale lipid imaging is demonstrated in a model organism and brain slice.</p></td></tr></thead></table>-
dc.languageeng-
dc.relation.ispartofAdvanced Photonics Nexus-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.titleNoncontact photoacoustic lipid imaging by remote sensing on first overtone of the C-H bond-
dc.typeArticle-
dc.identifier.doi10.1117/1.APN.2.2.026011-
dc.identifier.volume2-
dc.identifier.issue2-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats