File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1393/ncc/i2018-18085-8
- Scopus: eid_2-s2.0-85065608155
- WOS: WOS:000444627100075
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Development of gaseous particle detectors based on semi-conductive plate electrodes
Title | Development of gaseous particle detectors based on semi-conductive plate electrodes |
---|---|
Authors | |
Issue Date | 2018 |
Citation | Nuovo Cimento della Societa Italiana di Fisica C, 2018, v. 41, n. 1-2, article no. 85 How to Cite? |
Abstract | A new kind of particle detector based on a Resistive Plate Chamber structure is under development. Semi-conductive electrodes with resistivity up to 10 8 Ω cm are introduced to improve the Rate Capability performance. In this paper some results on the configurations under test are described. The DC Voltampero-metric characterization of a SI-GaAs sample measured applying metal electrodes on the substrate is also reported. |
Persistent Identifier | http://hdl.handle.net/10722/327581 |
ISSN | 2023 Impact Factor: 0.3 2023 SCImago Journal Rankings: 0.180 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Rocchi, A. | - |
dc.contributor.author | Cardarelli, R. | - |
dc.contributor.author | Bruno, S. | - |
dc.contributor.author | Caltabiano, A. | - |
dc.contributor.author | Camarri, P. | - |
dc.contributor.author | Di Ciaccio, A. | - |
dc.contributor.author | Pizzimento, L. | - |
dc.date.accessioned | 2023-04-03T12:27:49Z | - |
dc.date.available | 2023-04-03T12:27:49Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | Nuovo Cimento della Societa Italiana di Fisica C, 2018, v. 41, n. 1-2, article no. 85 | - |
dc.identifier.issn | 2037-4909 | - |
dc.identifier.uri | http://hdl.handle.net/10722/327581 | - |
dc.description.abstract | A new kind of particle detector based on a Resistive Plate Chamber structure is under development. Semi-conductive electrodes with resistivity up to 10 8 Ω cm are introduced to improve the Rate Capability performance. In this paper some results on the configurations under test are described. The DC Voltampero-metric characterization of a SI-GaAs sample measured applying metal electrodes on the substrate is also reported. | - |
dc.language | eng | - |
dc.relation.ispartof | Nuovo Cimento della Societa Italiana di Fisica C | - |
dc.title | Development of gaseous particle detectors based on semi-conductive plate electrodes | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1393/ncc/i2018-18085-8 | - |
dc.identifier.scopus | eid_2-s2.0-85065608155 | - |
dc.identifier.volume | 41 | - |
dc.identifier.issue | 1-2 | - |
dc.identifier.spage | article no. 85 | - |
dc.identifier.epage | article no. 85 | - |
dc.identifier.eissn | 1826-9885 | - |
dc.identifier.isi | WOS:000444627100075 | - |