Article: On a new environment-friendly gas mixture for Resistive Plate Chambers
Title | On a new environment-friendly gas mixture for Resistive Plate Chambers |
---|---|
Authors | |
Keywords | Gaseous detectors Resistive-plate chambers |
Issue Date | 2022 |
Citation | Journal of Instrumentation, 2022, v. 17, n. 5, article no. P05005 How to Cite? |
Abstract | This paper studies the performance of RPCs working with a new family of environment-friendly gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement of detection efficiency, avalanche-to-streamer transition probability, prompt and ionic charge delivered. The timing properties of the new gas are also measured. |
Persistent Identifier | http://hdl.handle.net/10722/327546 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Proto, G. | - |
dc.contributor.author | Liberti, B. | - |
dc.contributor.author | Santonico, R. | - |
dc.contributor.author | Aielli, G. | - |
dc.contributor.author | Camarri, P. | - |
dc.contributor.author | Cardarelli, R. | - |
dc.contributor.author | Di Ciaccio, A. | - |
dc.contributor.author | Di Stante, L. | - |
dc.contributor.author | Paoloni, A. | - |
dc.contributor.author | Pastori, E. | - |
dc.contributor.author | Pizzimento, L. | - |
dc.contributor.author | Rocchi, A. | - |
dc.date.accessioned | 2023-04-03T12:05:17Z | - |
dc.date.available | 2023-04-03T12:05:17Z | - |
dc.date.issued | 2022 | - |
dc.identifier.citation | Journal of Instrumentation, 2022, v. 17, n. 5, article no. P05005 | - |
dc.identifier.uri | http://hdl.handle.net/10722/327546 | - |
dc.description.abstract | This paper studies the performance of RPCs working with a new family of environment-friendly gases, mainly based on Carbon Dioxide and Hydro-Fluoro-Olefins. The tests are carried out on a 2 mm gap RPC and concern the measurement of detection efficiency, avalanche-to-streamer transition probability, prompt and ionic charge delivered. The timing properties of the new gas are also measured. | - |
dc.language | eng | - |
dc.relation.ispartof | Journal of Instrumentation | - |
dc.subject | Gaseous detectors | - |
dc.subject | Resistive-plate chambers | - |
dc.title | On a new environment-friendly gas mixture for Resistive Plate Chambers | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1088/1748-0221/17/05/P05005 | - |
dc.identifier.scopus | eid_2-s2.0-85130543764 | - |
dc.identifier.volume | 17 | - |
dc.identifier.issue | 5 | - |
dc.identifier.spage | article no. P05005 | - |
dc.identifier.epage | article no. P05005 | - |
dc.identifier.eissn | 1748-0221 | - |
dc.identifier.isi | WOS:000797317100007 | - |