File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: High-fidelity finite element simulation of non-contact splices in column-drilled shaft connections

TitleHigh-fidelity finite element simulation of non-contact splices in column-drilled shaft connections
Authors
KeywordsBridge column
Drilled shaft
Finite element simulation
Non-contact splice
Splice length
Splice spacing
Issue Date2021
Citation
Engineering Structures, 2021, v. 239, article no. 112186 How to Cite?
AbstractThe connection between columns and the supporting mono-drilled shafts is typically a construction joint. Such joints would often require the use of non-contact splices to facilitate a force transfer mechanism between the reinforcement of the column and drilled shaft due to the geometric irregularity or inadequate space at the interface. However, the application of non-contact splices has often been questioned due to limited investigation on the structural effect of non-contact splices in such connections. By utilizing available research findings and using an existing column-shaft connection consisting of non-contact splices as a prototype, a large-scale experimental investigation was conducted before this Finite Element (FE) simulation study. Subsequently, a three-dimensional FE simulation was performed to simulate the results from the experimental program. Data from the experimental program was used to validate the finite element model developed in this study. Afterward, the model was utilized to perform an FE-based parametric analysis to examine the influence of the factors that affect the performance of non-contact splices. This paper discusses the details of the FE simulation and reports the findings from the parametric analysis. The research findings from the FE simulation and parametric study can provide valuable guidance on designing and constructing a safe and efficient non-contact lap spliced construction joint between a column and a drilled shaft.
Persistent Identifierhttp://hdl.handle.net/10722/326279
ISSN
2023 Impact Factor: 5.6
2023 SCImago Journal Rankings: 1.661
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorMasud, Mahadi-
dc.contributor.authorChen, Hongbing-
dc.contributor.authorWang, Jiaji-
dc.contributor.authorSawab, Jamshaid-
dc.contributor.authorMo, Y. L.-
dc.contributor.authorHsu, Thomas T.C.-
dc.date.accessioned2023-03-09T09:59:26Z-
dc.date.available2023-03-09T09:59:26Z-
dc.date.issued2021-
dc.identifier.citationEngineering Structures, 2021, v. 239, article no. 112186-
dc.identifier.issn0141-0296-
dc.identifier.urihttp://hdl.handle.net/10722/326279-
dc.description.abstractThe connection between columns and the supporting mono-drilled shafts is typically a construction joint. Such joints would often require the use of non-contact splices to facilitate a force transfer mechanism between the reinforcement of the column and drilled shaft due to the geometric irregularity or inadequate space at the interface. However, the application of non-contact splices has often been questioned due to limited investigation on the structural effect of non-contact splices in such connections. By utilizing available research findings and using an existing column-shaft connection consisting of non-contact splices as a prototype, a large-scale experimental investigation was conducted before this Finite Element (FE) simulation study. Subsequently, a three-dimensional FE simulation was performed to simulate the results from the experimental program. Data from the experimental program was used to validate the finite element model developed in this study. Afterward, the model was utilized to perform an FE-based parametric analysis to examine the influence of the factors that affect the performance of non-contact splices. This paper discusses the details of the FE simulation and reports the findings from the parametric analysis. The research findings from the FE simulation and parametric study can provide valuable guidance on designing and constructing a safe and efficient non-contact lap spliced construction joint between a column and a drilled shaft.-
dc.languageeng-
dc.relation.ispartofEngineering Structures-
dc.subjectBridge column-
dc.subjectDrilled shaft-
dc.subjectFinite element simulation-
dc.subjectNon-contact splice-
dc.subjectSplice length-
dc.subjectSplice spacing-
dc.titleHigh-fidelity finite element simulation of non-contact splices in column-drilled shaft connections-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/j.engstruct.2021.112186-
dc.identifier.scopuseid_2-s2.0-85103991082-
dc.identifier.volume239-
dc.identifier.spagearticle no. 112186-
dc.identifier.epagearticle no. 112186-
dc.identifier.eissn1873-7323-
dc.identifier.isiWOS:000657381800003-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats