File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Single burr hole rigid endoscopic third ventriculostomy and endoscopic tumor biopsy: What is the safe displacement range for the foramen of Monro?

TitleSingle burr hole rigid endoscopic third ventriculostomy and endoscopic tumor biopsy: What is the safe displacement range for the foramen of Monro?
Authors
Keywordsendoscopic biopsy
endoscopy
hydrocephalus
neuronavigation
pineal region tumor
third ventricular tumor
third ventriculostomy
Issue Date2013
Citation
Asian Journal of Surgery, 2013, v. 36, n. 2, p. 74-82 How to Cite?
AbstractObjective: To investigate the safe displacement range of the foramen of Monro (FM) during single burr hole rigid endoscopic third ventriculostomy (ETV) and endoscopic tumor biopsy (ETB). Methods: Eleven patients who received ETV/ETB for third ventricular and pineal region tumor were reviewed. The burr-hole location, the size, and the virtual displacement of FM were measured using neuronavigation software. Results: Hydrocephalus was resolved, and no subsequent cerebrospinal fluid (CSF) shunting was required in all cases. Histological diagnosis was established in 11 patients. Ten cases received instrumental cognitive and memory assessment postoperatively. The results were within the normal range for eight cases. The mean burr-hole location was 1.7 cm anterior to coronal suture and 3 cm from the midline. The mean diameters of FM measured on the axial, coronal, sagittal, and views were 5.7, 7.8, and 5.6 mm, respectively. The mean virtual displacements of the FM were 1.9 ± 2.0 mm (range = 0-4.8) for ETV and 2.4 ± 2.1 mm (range = 0-5.5) for ETB. The maximum displacements were 4.8 mm anteriorly for ETV and 5.5 mm posteriorly for ETB. Conclusion: Single burr hole rigid ETV/ETB is likely to be safe within maximum FM displacements of 4.8 mm anterior for ETV and 5.5 mm posterior for ETB. Preoperative trajectory planning using neuronavigation software is recommended. © 2013 Elsevier Inc. All rights reserved.
Persistent Identifierhttp://hdl.handle.net/10722/325261
ISSN
2023 Impact Factor: 3.5
2023 SCImago Journal Rankings: 0.538
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorZhu, Xian Lun-
dc.contributor.authorGao, Rong-
dc.contributor.authorWong, George Kwok Chu-
dc.contributor.authorWong, Hoi Tung-
dc.contributor.authorNg, Rebecca Yuen Ting-
dc.contributor.authorYu, Yong-
dc.contributor.authorWong, Rosanna Kit Man-
dc.contributor.authorPoon, Wai Sang-
dc.date.accessioned2023-02-27T07:31:02Z-
dc.date.available2023-02-27T07:31:02Z-
dc.date.issued2013-
dc.identifier.citationAsian Journal of Surgery, 2013, v. 36, n. 2, p. 74-82-
dc.identifier.issn1015-9584-
dc.identifier.urihttp://hdl.handle.net/10722/325261-
dc.description.abstractObjective: To investigate the safe displacement range of the foramen of Monro (FM) during single burr hole rigid endoscopic third ventriculostomy (ETV) and endoscopic tumor biopsy (ETB). Methods: Eleven patients who received ETV/ETB for third ventricular and pineal region tumor were reviewed. The burr-hole location, the size, and the virtual displacement of FM were measured using neuronavigation software. Results: Hydrocephalus was resolved, and no subsequent cerebrospinal fluid (CSF) shunting was required in all cases. Histological diagnosis was established in 11 patients. Ten cases received instrumental cognitive and memory assessment postoperatively. The results were within the normal range for eight cases. The mean burr-hole location was 1.7 cm anterior to coronal suture and 3 cm from the midline. The mean diameters of FM measured on the axial, coronal, sagittal, and views were 5.7, 7.8, and 5.6 mm, respectively. The mean virtual displacements of the FM were 1.9 ± 2.0 mm (range = 0-4.8) for ETV and 2.4 ± 2.1 mm (range = 0-5.5) for ETB. The maximum displacements were 4.8 mm anteriorly for ETV and 5.5 mm posteriorly for ETB. Conclusion: Single burr hole rigid ETV/ETB is likely to be safe within maximum FM displacements of 4.8 mm anterior for ETV and 5.5 mm posterior for ETB. Preoperative trajectory planning using neuronavigation software is recommended. © 2013 Elsevier Inc. All rights reserved.-
dc.languageeng-
dc.relation.ispartofAsian Journal of Surgery-
dc.subjectendoscopic biopsy-
dc.subjectendoscopy-
dc.subjecthydrocephalus-
dc.subjectneuronavigation-
dc.subjectpineal region tumor-
dc.subjectthird ventricular tumor-
dc.subjectthird ventriculostomy-
dc.titleSingle burr hole rigid endoscopic third ventriculostomy and endoscopic tumor biopsy: What is the safe displacement range for the foramen of Monro?-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1016/j.asjsur.2012.11.008-
dc.identifier.pmid23522759-
dc.identifier.scopuseid_2-s2.0-84875443705-
dc.identifier.volume36-
dc.identifier.issue2-
dc.identifier.spage74-
dc.identifier.epage82-
dc.identifier.eissn0219-3108-
dc.identifier.isiWOS:000319026300005-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats