File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Dual-echo arteriovenography imaging with 7T MRI

TitleDual-echo arteriovenography imaging with 7T MRI
Authors
KeywordsBlood oxygenation level-dependent venography
Brain imaging
CODEA
Dual-echo technique
High-field MR
MR angiography
Susceptibility-weighted imaging
Time-of-flight
Issue Date2010
Citation
Journal of Magnetic Resonance Imaging, 2010, v. 31, n. 1, p. 255-261 How to Cite?
AbstractPurpose: To implement a dual-echo sequence MRI technique at 7T for simultaneous acquisition of time-of-flight (TOF) MR angiogram (MRA) and blood oxygenation level-dependent (BOLD) MR venogram (MRV) in a single MR acquisition and to compare the image qualities with those acquired at 3T. Materials and Methods: We implemented a dual-echo sequence with an echo-specific k-space reordering scheme to uncouple the scan parameter requirements for MRA and MRV at 7T. The MRA and MRV vascular contrast was enhanced by maximally separating the k-space center regions acquired for the MRA and MRV and by adjusting and applying scan parameters compatible between the MRA and MRV. The same imaging sequence was implemented at 3T. Four normal subjects were imaged at both 3T and 7T. MRA and MRV at 7T were reconstructed both with and without phase-mask filtering and were compared quantitatively and qualitatively with those at 3T with phase-mask filtering. Results: The depiction of small cortical arteries and veins on MRA and MRV at 7T was substantially better than that at 3T, due to about twice higher contrast-tonoise ratio (CNR) for both arteries (164 ±57 vs. 77 ± 26) and veins (72 ± 8 vs. 36 ± 6). Even without use of the phase-masking filtering, the venous contrast at 7T (65 ± 7) was higher than that with the filtering at 3T (36 ± 6). Conclusion: The dual-echo arteriovenography technique we implemented at 7T allows the improved visualization of small vessels in both the MRA and MRV because of the greatly increased signal-to-noise ratio (SNR) and susceptibility contrast, compared to 3T. © 2009 Wiley-Liss, Inc.
Persistent Identifierhttp://hdl.handle.net/10722/316029
ISSN
2023 Impact Factor: 3.3
2023 SCImago Journal Rankings: 1.339
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorBae, Kyongtae Ty-
dc.contributor.authorPark, Sung Hong-
dc.contributor.authorMoon, Chan Hong-
dc.contributor.authorKim, Jung Hwan-
dc.contributor.authorKaya, Diana-
dc.contributor.authorZhao, Tiejun-
dc.date.accessioned2022-08-24T15:49:00Z-
dc.date.available2022-08-24T15:49:00Z-
dc.date.issued2010-
dc.identifier.citationJournal of Magnetic Resonance Imaging, 2010, v. 31, n. 1, p. 255-261-
dc.identifier.issn1053-1807-
dc.identifier.urihttp://hdl.handle.net/10722/316029-
dc.description.abstractPurpose: To implement a dual-echo sequence MRI technique at 7T for simultaneous acquisition of time-of-flight (TOF) MR angiogram (MRA) and blood oxygenation level-dependent (BOLD) MR venogram (MRV) in a single MR acquisition and to compare the image qualities with those acquired at 3T. Materials and Methods: We implemented a dual-echo sequence with an echo-specific k-space reordering scheme to uncouple the scan parameter requirements for MRA and MRV at 7T. The MRA and MRV vascular contrast was enhanced by maximally separating the k-space center regions acquired for the MRA and MRV and by adjusting and applying scan parameters compatible between the MRA and MRV. The same imaging sequence was implemented at 3T. Four normal subjects were imaged at both 3T and 7T. MRA and MRV at 7T were reconstructed both with and without phase-mask filtering and were compared quantitatively and qualitatively with those at 3T with phase-mask filtering. Results: The depiction of small cortical arteries and veins on MRA and MRV at 7T was substantially better than that at 3T, due to about twice higher contrast-tonoise ratio (CNR) for both arteries (164 ±57 vs. 77 ± 26) and veins (72 ± 8 vs. 36 ± 6). Even without use of the phase-masking filtering, the venous contrast at 7T (65 ± 7) was higher than that with the filtering at 3T (36 ± 6). Conclusion: The dual-echo arteriovenography technique we implemented at 7T allows the improved visualization of small vessels in both the MRA and MRV because of the greatly increased signal-to-noise ratio (SNR) and susceptibility contrast, compared to 3T. © 2009 Wiley-Liss, Inc.-
dc.languageeng-
dc.relation.ispartofJournal of Magnetic Resonance Imaging-
dc.subjectBlood oxygenation level-dependent venography-
dc.subjectBrain imaging-
dc.subjectCODEA-
dc.subjectDual-echo technique-
dc.subjectHigh-field MR-
dc.subjectMR angiography-
dc.subjectSusceptibility-weighted imaging-
dc.subjectTime-of-flight-
dc.titleDual-echo arteriovenography imaging with 7T MRI-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1002/jmri.22019-
dc.identifier.pmid20027596-
dc.identifier.scopuseid_2-s2.0-74049095477-
dc.identifier.volume31-
dc.identifier.issue1-
dc.identifier.spage255-
dc.identifier.epage261-
dc.identifier.eissn1522-2586-
dc.identifier.isiWOS:000273336100033-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats