File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1002/mrm.21935
- Scopus: eid_2-s2.0-66249103950
- PMID: 19191284
- WOS: WOS:000264499000003
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Compatible dual-echo arteriovenography (codea) using an echo-specific K-space reordering scheme
Title | Compatible dual-echo arteriovenography (codea) using an echo-specific K-space reordering scheme |
---|---|
Authors | |
Keywords | Blood-oxygenationlevel-dependent venography Brain imaging Codea Dual-echo technique MR angiography Multiple overiapping thin-slab acquisition Susceptibility-weighted imaging Tilted optimized nonsaturating excitation Time-of-flight |
Issue Date | 2009 |
Citation | Magnetic Resonance in Medicine, 2009, v. 61, n. 4, p. 767-774 How to Cite? |
Abstract | An improved dual-echo sequence magentic resonance (MR) imaging technique was developed to simultaneously acquire a time-of-flight MR angiogram (MRA) and a blood oxygenation level-dependent MR venogram (MRV) in a single MR acquisition at 3 T. MRA and MRV require conflicting scan conditions (e.g., excitation RF profile, flip angle, and spatial presaturation pulse) for their optimal image quality. This conflict was not well counterbalanced or reconciled in previous methods reported for simultaneous acquisition of MRA and MRV. In our dual-echo sequence method, an echo-specific K-space reordering scheme was used to uncouple the scan parameter requirements for MRA and MRV. The MRA and MRV vascular contrast was enhanced by maximally separating the K-space center regions acquired for the MRA and MRV, and by adjusting and applying scan parameters compatible between the MRA and MRV. As a preliminary result, we were able to acquire a simultaneous dual-echo MRA and MRV with image quality comparable to that of the conventional single-echo MRA and MRV that were acquired separately at two different sessions. Furthermore, integrated with tilted optimized nonsaturating excitation and multiple overlapping thin-slab acquisition techniques, our dual-echo MRA and MRV provided seamless vascular continuity over a large coverage volume of the brain anatomy. © 2009 Wiley-Liss, Inc. |
Persistent Identifier | http://hdl.handle.net/10722/316021 |
ISSN | 2023 Impact Factor: 3.0 2023 SCImago Journal Rankings: 1.343 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Sung Hong | - |
dc.contributor.author | Moon, Chan Hong | - |
dc.contributor.author | Bae, Kyongtae Ty | - |
dc.date.accessioned | 2022-08-24T15:48:58Z | - |
dc.date.available | 2022-08-24T15:48:58Z | - |
dc.date.issued | 2009 | - |
dc.identifier.citation | Magnetic Resonance in Medicine, 2009, v. 61, n. 4, p. 767-774 | - |
dc.identifier.issn | 0740-3194 | - |
dc.identifier.uri | http://hdl.handle.net/10722/316021 | - |
dc.description.abstract | An improved dual-echo sequence magentic resonance (MR) imaging technique was developed to simultaneously acquire a time-of-flight MR angiogram (MRA) and a blood oxygenation level-dependent MR venogram (MRV) in a single MR acquisition at 3 T. MRA and MRV require conflicting scan conditions (e.g., excitation RF profile, flip angle, and spatial presaturation pulse) for their optimal image quality. This conflict was not well counterbalanced or reconciled in previous methods reported for simultaneous acquisition of MRA and MRV. In our dual-echo sequence method, an echo-specific K-space reordering scheme was used to uncouple the scan parameter requirements for MRA and MRV. The MRA and MRV vascular contrast was enhanced by maximally separating the K-space center regions acquired for the MRA and MRV, and by adjusting and applying scan parameters compatible between the MRA and MRV. As a preliminary result, we were able to acquire a simultaneous dual-echo MRA and MRV with image quality comparable to that of the conventional single-echo MRA and MRV that were acquired separately at two different sessions. Furthermore, integrated with tilted optimized nonsaturating excitation and multiple overlapping thin-slab acquisition techniques, our dual-echo MRA and MRV provided seamless vascular continuity over a large coverage volume of the brain anatomy. © 2009 Wiley-Liss, Inc. | - |
dc.language | eng | - |
dc.relation.ispartof | Magnetic Resonance in Medicine | - |
dc.subject | Blood-oxygenationlevel-dependent venography | - |
dc.subject | Brain imaging | - |
dc.subject | Codea | - |
dc.subject | Dual-echo technique | - |
dc.subject | MR angiography | - |
dc.subject | Multiple overiapping thin-slab acquisition | - |
dc.subject | Susceptibility-weighted imaging | - |
dc.subject | Tilted optimized nonsaturating excitation | - |
dc.subject | Time-of-flight | - |
dc.title | Compatible dual-echo arteriovenography (codea) using an echo-specific K-space reordering scheme | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1002/mrm.21935 | - |
dc.identifier.pmid | 19191284 | - |
dc.identifier.scopus | eid_2-s2.0-66249103950 | - |
dc.identifier.volume | 61 | - |
dc.identifier.issue | 4 | - |
dc.identifier.spage | 767 | - |
dc.identifier.epage | 774 | - |
dc.identifier.eissn | 1522-2594 | - |
dc.identifier.isi | WOS:000264499000003 | - |