File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: A wavelet method for metal artifact reduction with multiple metallic objects in the field of view

TitleA wavelet method for metal artifact reduction with multiple metallic objects in the field of view
Authors
KeywordsImage quality
Metal artifact reduction (MAR)
Multiresolution
Wavelet
X-ray computed tomography (CT)
Issue Date2002
Citation
Journal of X-Ray Science and Technology, 2002, v. 10, n. 1-2, p. 67-76 How to Cite?
AbstractImage artifacts induced by multiple metallic objects pose a persistent problem in X-ray computed tomography (CT). Among existing CT methods for metal artifact reduction, the wavelet-based approach we recently developed is very promising in practice. In this paper, we report a major refinement to our earlier work. The key component of this refinement is a novel weighting scheme for wavelet multiresolution interpolation. This weighting scheme is designed specifically to take into account multiple metallic implants in the field of view. In contrast to commonly used noniterative algorithms, our algorithm identifies and corrects most seriously corrupted projection data based on wavelet multiresolution analysis. Experimental results indicate that the proposed algorithm significantly improves the image quality, and clearly reveals anatomic details in the immediate vicinity of multiple metallic implants.
Persistent Identifierhttp://hdl.handle.net/10722/315924
ISSN
2023 Impact Factor: 1.7
2023 SCImago Journal Rankings: 0.501
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorZhao, Shiying-
dc.contributor.authorBae, Kyongtae T.-
dc.contributor.authorWhiting, Bruce-
dc.contributor.authorWang, Ge-
dc.date.accessioned2022-08-24T15:48:37Z-
dc.date.available2022-08-24T15:48:37Z-
dc.date.issued2002-
dc.identifier.citationJournal of X-Ray Science and Technology, 2002, v. 10, n. 1-2, p. 67-76-
dc.identifier.issn0895-3996-
dc.identifier.urihttp://hdl.handle.net/10722/315924-
dc.description.abstractImage artifacts induced by multiple metallic objects pose a persistent problem in X-ray computed tomography (CT). Among existing CT methods for metal artifact reduction, the wavelet-based approach we recently developed is very promising in practice. In this paper, we report a major refinement to our earlier work. The key component of this refinement is a novel weighting scheme for wavelet multiresolution interpolation. This weighting scheme is designed specifically to take into account multiple metallic implants in the field of view. In contrast to commonly used noniterative algorithms, our algorithm identifies and corrects most seriously corrupted projection data based on wavelet multiresolution analysis. Experimental results indicate that the proposed algorithm significantly improves the image quality, and clearly reveals anatomic details in the immediate vicinity of multiple metallic implants.-
dc.languageeng-
dc.relation.ispartofJournal of X-Ray Science and Technology-
dc.subjectImage quality-
dc.subjectMetal artifact reduction (MAR)-
dc.subjectMultiresolution-
dc.subjectWavelet-
dc.subjectX-ray computed tomography (CT)-
dc.titleA wavelet method for metal artifact reduction with multiple metallic objects in the field of view-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.scopuseid_2-s2.0-0036042213-
dc.identifier.volume10-
dc.identifier.issue1-2-
dc.identifier.spage67-
dc.identifier.epage76-
dc.identifier.isiWOS:000207066600005-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats