File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Shift-variant color-coded diffractive spectral imaging system

TitleShift-variant color-coded diffractive spectral imaging system
Authors
Issue Date2021
Citation
Optica, 2021, v. 8, n. 11, p. 1424-1434 How to Cite?
AbstractState-of-the-art snapshot spectral imaging (SI) systems introduce color-coded apertures (CCAs) into their setups to obtain a flexible spatial-spectral modulation, allowing spectral information to be reconstructed from a set of coded measurements. Besides the CCA, other optical elements, such as lenses, prisms, or beam splitters, are usually employed, making systems large and impractical. Recently, diffractive optical elements (DOEs) have partially replaced refractive lenses to drastically reduce the size of the SI devices. The sensing model of these systems is represented as a projection modeled by a spatially shift-invariant convolution between the unknownscene and a point spread function (PSF) at each spectral band.However, the height maps of theDOEare the only free parameters that offer changes in the spectral modulation, which causes the ill-posedness of the reconstruction to increase significantly. To overcome this challenge, our work explores the advantages of the spectral modulation of an optical setup composed of aDOEand aCCA. Specifically, the light is diffracted by theDOEand then filtered by theCCA, located close to the sensor. A shift-variant property of the proposed system is clearly evidenced, resulting in a different PSF for each pixel, where a symmetric structure constraint is imposed on theCCAto reduce the high number of resulting PSFs. Additionally,we jointly design theDOEand theCCA parameters with a fully differentiable image formation model using an end-to-end approach to minimize the deviation between the true and reconstructed image over a large set of images. Simulation shows that the proposed system improves the spectral reconstruction quality in up to 4 dB compared with current state-of-the-art systems. Finally, experimental results with a fabricated prototype in indoor and outdoor scenes validate the proposed system, where it can recover up to 49 high-fidelity spectral bands in the 420-660 nm.
Persistent Identifierhttp://hdl.handle.net/10722/315373
ISSN
2023 Impact Factor: 8.4
2023 SCImago Journal Rankings: 3.549
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorArguello, Henry-
dc.contributor.authorPinilla, Samuel-
dc.contributor.authorPeng, Yifan-
dc.contributor.authorIkoma, Hayato-
dc.contributor.authorBacca, Jorge-
dc.contributor.authorWetzstein, Gordon-
dc.date.accessioned2022-08-05T10:18:39Z-
dc.date.available2022-08-05T10:18:39Z-
dc.date.issued2021-
dc.identifier.citationOptica, 2021, v. 8, n. 11, p. 1424-1434-
dc.identifier.issn2334-2536-
dc.identifier.urihttp://hdl.handle.net/10722/315373-
dc.description.abstractState-of-the-art snapshot spectral imaging (SI) systems introduce color-coded apertures (CCAs) into their setups to obtain a flexible spatial-spectral modulation, allowing spectral information to be reconstructed from a set of coded measurements. Besides the CCA, other optical elements, such as lenses, prisms, or beam splitters, are usually employed, making systems large and impractical. Recently, diffractive optical elements (DOEs) have partially replaced refractive lenses to drastically reduce the size of the SI devices. The sensing model of these systems is represented as a projection modeled by a spatially shift-invariant convolution between the unknownscene and a point spread function (PSF) at each spectral band.However, the height maps of theDOEare the only free parameters that offer changes in the spectral modulation, which causes the ill-posedness of the reconstruction to increase significantly. To overcome this challenge, our work explores the advantages of the spectral modulation of an optical setup composed of aDOEand aCCA. Specifically, the light is diffracted by theDOEand then filtered by theCCA, located close to the sensor. A shift-variant property of the proposed system is clearly evidenced, resulting in a different PSF for each pixel, where a symmetric structure constraint is imposed on theCCAto reduce the high number of resulting PSFs. Additionally,we jointly design theDOEand theCCA parameters with a fully differentiable image formation model using an end-to-end approach to minimize the deviation between the true and reconstructed image over a large set of images. Simulation shows that the proposed system improves the spectral reconstruction quality in up to 4 dB compared with current state-of-the-art systems. Finally, experimental results with a fabricated prototype in indoor and outdoor scenes validate the proposed system, where it can recover up to 49 high-fidelity spectral bands in the 420-660 nm.-
dc.languageeng-
dc.relation.ispartofOptica-
dc.titleShift-variant color-coded diffractive spectral imaging system-
dc.typeArticle-
dc.description.naturelink_to_subscribed_fulltext-
dc.identifier.doi10.1364/OPTICA.439142-
dc.identifier.scopuseid_2-s2.0-85120338074-
dc.identifier.volume8-
dc.identifier.issue11-
dc.identifier.spage1424-
dc.identifier.epage1434-
dc.identifier.isiWOS:000720968200012-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats