File Download
  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Power Output of Two Semiconductor Lasers: An Observational Study

TitlePower Output of Two Semiconductor Lasers: An Observational Study
Authors
Keywordsdiode
laser
parameter
power
semiconductor
Issue Date2022
Citation
Photonics, 2022, v. 9 n. 4, article no. 219 How to Cite?
AbstractAbstract: The objective of this study was to evaluate the power output of two dental devices. The study examined two semiconductor lasers, namely, SIROLaser Blue (445nm, 970 nm) and Picasso (810nm). The power output performance was studied at the maximum output power of the devices. The study compared the preset power output measured by a power meter in a continuous-wave mode and in pulsed mode at 50% duty cycles. Ten 60s measurements were performed for each setting. The largest difference between the stipulated and the actual output power at continuous-wave (D-cw) and pulsed (D-p) modes was calculated. Moreover, the percentage variations in the mean output power at continuous-wave (%D-cw) and pulsed (%D-p) modes were calculated. The D-cw values for 445 nm, 970 nm, and 810 nm lasers were 0.7 W, 0.5 W, and -0.3 W, respectively, and %D-cw values were21%, 23%, and -8%, respectively. The D-p values were 37%, 26%, and -3%, respectively. This study found that the actual power is not necessarily lower but can be higher than the displayed power output. Clinicians are recommended to calibrate the laser output by using a power meter before use.
Persistent Identifierhttp://hdl.handle.net/10722/314124
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorXU, W-
dc.contributor.authorYin, X-
dc.contributor.authorNiu, Y-
dc.contributor.authorLuk, K-
dc.contributor.authorLo, ECM-
dc.contributor.authorChu, CH-
dc.date.accessioned2022-07-18T06:12:11Z-
dc.date.available2022-07-18T06:12:11Z-
dc.date.issued2022-
dc.identifier.citationPhotonics, 2022, v. 9 n. 4, article no. 219-
dc.identifier.urihttp://hdl.handle.net/10722/314124-
dc.description.abstractAbstract: The objective of this study was to evaluate the power output of two dental devices. The study examined two semiconductor lasers, namely, SIROLaser Blue (445nm, 970 nm) and Picasso (810nm). The power output performance was studied at the maximum output power of the devices. The study compared the preset power output measured by a power meter in a continuous-wave mode and in pulsed mode at 50% duty cycles. Ten 60s measurements were performed for each setting. The largest difference between the stipulated and the actual output power at continuous-wave (D-cw) and pulsed (D-p) modes was calculated. Moreover, the percentage variations in the mean output power at continuous-wave (%D-cw) and pulsed (%D-p) modes were calculated. The D-cw values for 445 nm, 970 nm, and 810 nm lasers were 0.7 W, 0.5 W, and -0.3 W, respectively, and %D-cw values were21%, 23%, and -8%, respectively. The D-p values were 37%, 26%, and -3%, respectively. This study found that the actual power is not necessarily lower but can be higher than the displayed power output. Clinicians are recommended to calibrate the laser output by using a power meter before use.-
dc.languageeng-
dc.relation.ispartofPhotonics-
dc.rightsThis work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.-
dc.subjectdiode-
dc.subjectlaser-
dc.subjectparameter-
dc.subjectpower-
dc.subjectsemiconductor-
dc.titlePower Output of Two Semiconductor Lasers: An Observational Study-
dc.typeArticle-
dc.identifier.emailYin, X: irisxyin@hku.hk-
dc.identifier.emailLo, ECM: edward-lo@hku.hk-
dc.identifier.emailChu, CH: chchu@hku.hk-
dc.identifier.authorityLo, ECM=rp00015-
dc.identifier.authorityChu, CH=rp00022-
dc.description.naturepublished_or_final_version-
dc.identifier.doi10.3390/photonics9040219-
dc.identifier.scopuseid_2-s2.0-85128047212-
dc.identifier.hkuros334075-
dc.identifier.volume9-
dc.identifier.issue4-
dc.identifier.spage219-
dc.identifier.spagearticle no. 219-
dc.identifier.epage219-
dc.identifier.epagearticle no. 219-
dc.identifier.isiWOS:000785175100001-

Export via OAI-PMH Interface in XML Formats