File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1109/INFOCOM.2018.8485978
- Scopus: eid_2-s2.0-85056186960
- WOS: WOS:000509768900176
- Find via
Supplementary
- Citations:
- Appears in Collections:
Conference Paper: Acousticcardiogram: Monitoring Heartbeats using Acoustic Signals on Smart Devices
Title | Acousticcardiogram: Monitoring Heartbeats using Acoustic Signals on Smart Devices |
---|---|
Authors | |
Issue Date | 2018 |
Citation | Proceedings - IEEE INFOCOM, 2018, v. 2018-April, p. 1574-1582 How to Cite? |
Abstract | Vital signs such as heart rate and heartbeat interval are currently measured by electrocardiograms (ECG) or wearable physiological monitors. These techniques either require contact with the patient's skin or are usually uncomfortable to wear, rendering them too expensive and user-unfriendly for daily monitoring. In this paper, we propose a new noninvasive technology to generate an Acousticcardiogram (ACG) that precisely monitors heartbeats using inaudible acoustic signals. ACG uses only commodity microphones and speakers commonly equipped on ubiquitous off-the-shelf devices, such as smartphones and laptops. By transmitting an acoustic signal and analyzing its reflections off human body, ACG is capable of recognizing the heart rate as well as heartbeat rhythm. We employ frequency-modulated sound signals to separate reflection of heart from that of background motions and breath, and continuously track the phase changes of the acoustic data. To translate these acoustic data into heart and breath rates, we leverage the dual microphone design on COTS mobile devices to suppress direct echo from speaker to microphones, identify heart rate in frequency domain, and adopt an advanced algorithm to extract individual heartbeats. We implement ACG on commercial devices and validate its performance in real environments. Experimental results demonstrate ACG monitors user's heartbeat accurately, with median heart rate estimation error of 0.6 beat per minute (bpm), and median heartbeat interval estimation error of 19 ms. |
Persistent Identifier | http://hdl.handle.net/10722/303868 |
ISSN | 2023 SCImago Journal Rankings: 2.865 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Qian, Kun | - |
dc.contributor.author | Wu, Chenshu | - |
dc.contributor.author | Xiao, Fu | - |
dc.contributor.author | Zheng, Yue | - |
dc.contributor.author | Zhang, Yi | - |
dc.contributor.author | Yang, Zheng | - |
dc.contributor.author | Liu, Yunhao | - |
dc.date.accessioned | 2021-09-15T08:26:10Z | - |
dc.date.available | 2021-09-15T08:26:10Z | - |
dc.date.issued | 2018 | - |
dc.identifier.citation | Proceedings - IEEE INFOCOM, 2018, v. 2018-April, p. 1574-1582 | - |
dc.identifier.issn | 0743-166X | - |
dc.identifier.uri | http://hdl.handle.net/10722/303868 | - |
dc.description.abstract | Vital signs such as heart rate and heartbeat interval are currently measured by electrocardiograms (ECG) or wearable physiological monitors. These techniques either require contact with the patient's skin or are usually uncomfortable to wear, rendering them too expensive and user-unfriendly for daily monitoring. In this paper, we propose a new noninvasive technology to generate an Acousticcardiogram (ACG) that precisely monitors heartbeats using inaudible acoustic signals. ACG uses only commodity microphones and speakers commonly equipped on ubiquitous off-the-shelf devices, such as smartphones and laptops. By transmitting an acoustic signal and analyzing its reflections off human body, ACG is capable of recognizing the heart rate as well as heartbeat rhythm. We employ frequency-modulated sound signals to separate reflection of heart from that of background motions and breath, and continuously track the phase changes of the acoustic data. To translate these acoustic data into heart and breath rates, we leverage the dual microphone design on COTS mobile devices to suppress direct echo from speaker to microphones, identify heart rate in frequency domain, and adopt an advanced algorithm to extract individual heartbeats. We implement ACG on commercial devices and validate its performance in real environments. Experimental results demonstrate ACG monitors user's heartbeat accurately, with median heart rate estimation error of 0.6 beat per minute (bpm), and median heartbeat interval estimation error of 19 ms. | - |
dc.language | eng | - |
dc.relation.ispartof | Proceedings - IEEE INFOCOM | - |
dc.title | Acousticcardiogram: Monitoring Heartbeats using Acoustic Signals on Smart Devices | - |
dc.type | Conference_Paper | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1109/INFOCOM.2018.8485978 | - |
dc.identifier.scopus | eid_2-s2.0-85056186960 | - |
dc.identifier.volume | 2018-April | - |
dc.identifier.spage | 1574 | - |
dc.identifier.epage | 1582 | - |
dc.identifier.isi | WOS:000509768900176 | - |