File Download

There are no files associated with this item.

  Links for fulltext
     (May Require Subscription)
Supplementary

Article: Characterization of corneal tangent modulus in vivo

TitleCharacterization of corneal tangent modulus in vivo
Authors
Keywordsglaucoma
corneal biomechanical properties
indentation instrumentation
tangent elastic modulus
stiffness
Issue Date2013
Citation
Acta Ophthalmologica, 2013, v. 91, n. 4, p. e263-e269 How to Cite?
AbstractPurpose: Intraocular pressure (IOP) measured using Goldmann Applanation Tonometry (GAT) changes with individual's corneal properties, but the method to measure the in vivo corneal material properties to account for individual variation in GAT IOP is not available. In this study, a new method to measure the IOP-dependent corneal tangent modulus in vivo is developed to address this research gap. Methods: Instrumented indentation and analysis were developed to measure the corneal tangent modulus. The validity of the method and procedure was verified using model silicone eye pressurized to different IOP. In addition, 15 porcine eyes and 3 rabbit eyes were tested using the corneal indentation at different set intraocular pressure and different indentation rates. Results: The results from silicone eye showed that the measured tangent modulus is in good agreement with the standard silicone rubber modulus. The results on the porcine eyes and rabbit eyes showed that the method can be used to measure corneal tangent modulus in vivo in the human range of intraocular pressure from 10 to 40 mmHg. Conclusions: An indentation method to measure the corneal tangent modulus in vivo was developed, and the IOP dependence of the corneal tangent modulus was characterized. The developed indentation method provides a new means to measure the in vivo corneal tangent modulus to account for individual and pressure variations in measurement of intraocular pressure. © 2013 Acta Ophthalmologica Scandinavica Foundation Published by Blackwell Publishing Ltd.
Persistent Identifierhttp://hdl.handle.net/10722/298034
ISSN
2023 Impact Factor: 3.0
2023 SCImago Journal Rankings: 1.404
ISI Accession Number ID

 

DC FieldValueLanguage
dc.contributor.authorKo, Match W.L.-
dc.contributor.authorLeung, Leo K.K.-
dc.contributor.authorLam, David C.C.-
dc.contributor.authorLeung, Christopher K.S.-
dc.date.accessioned2021-04-08T03:07:31Z-
dc.date.available2021-04-08T03:07:31Z-
dc.date.issued2013-
dc.identifier.citationActa Ophthalmologica, 2013, v. 91, n. 4, p. e263-e269-
dc.identifier.issn1755-375X-
dc.identifier.urihttp://hdl.handle.net/10722/298034-
dc.description.abstractPurpose: Intraocular pressure (IOP) measured using Goldmann Applanation Tonometry (GAT) changes with individual's corneal properties, but the method to measure the in vivo corneal material properties to account for individual variation in GAT IOP is not available. In this study, a new method to measure the IOP-dependent corneal tangent modulus in vivo is developed to address this research gap. Methods: Instrumented indentation and analysis were developed to measure the corneal tangent modulus. The validity of the method and procedure was verified using model silicone eye pressurized to different IOP. In addition, 15 porcine eyes and 3 rabbit eyes were tested using the corneal indentation at different set intraocular pressure and different indentation rates. Results: The results from silicone eye showed that the measured tangent modulus is in good agreement with the standard silicone rubber modulus. The results on the porcine eyes and rabbit eyes showed that the method can be used to measure corneal tangent modulus in vivo in the human range of intraocular pressure from 10 to 40 mmHg. Conclusions: An indentation method to measure the corneal tangent modulus in vivo was developed, and the IOP dependence of the corneal tangent modulus was characterized. The developed indentation method provides a new means to measure the in vivo corneal tangent modulus to account for individual and pressure variations in measurement of intraocular pressure. © 2013 Acta Ophthalmologica Scandinavica Foundation Published by Blackwell Publishing Ltd.-
dc.languageeng-
dc.relation.ispartofActa Ophthalmologica-
dc.subjectglaucoma-
dc.subjectcorneal biomechanical properties-
dc.subjectindentation instrumentation-
dc.subjecttangent elastic modulus-
dc.subjectstiffness-
dc.titleCharacterization of corneal tangent modulus in vivo-
dc.typeArticle-
dc.description.naturelink_to_OA_fulltext-
dc.identifier.doi10.1111/aos.12066-
dc.identifier.pmid23336962-
dc.identifier.scopuseid_2-s2.0-84878444245-
dc.identifier.volume91-
dc.identifier.issue4-
dc.identifier.spagee263-
dc.identifier.epagee269-
dc.identifier.eissn1755-3768-
dc.identifier.isiWOS:000334387500003-
dc.identifier.issnl1755-375X-

Export via OAI-PMH Interface in XML Formats


OR


Export to Other Non-XML Formats