File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1109/TPEL.2019.2953603
- Scopus: eid_2-s2.0-85083957185
- WOS: WOS:000530303600028
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Integration of Flexible Loads and Electric Spring Using a Three-Phase Inverter
Title | Integration of Flexible Loads and Electric Spring Using a Three-Phase Inverter |
---|---|
Authors | |
Keywords | Electric spring (ES) flexible loads pulsewidth modulation converters smart grids |
Issue Date | 2020 |
Publisher | Institute of Electrical and Electronics Engineers. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=63 |
Citation | IEEE Transactions on Power Electronics, 2020, v. 35 n. 8, p. 8013-8024 How to Cite? |
Abstract | In this article, a new structure of the electric spring (ES) system using a three-phase inverter is proposed. Noncritical or flexible loads associated with ES can be turned into a smart load. The smart load consumes power adaptively to achieve quick demand response in the future smart grid. Compared to previous ES topologies, the new structure of ES eliminates the battery storage and isolation transformer. The benefit of size and weight reduction results in further improvement on power density of the system. The control strategy is developed and the optimal operating condition for the new ES system is explicitly studied. Power inverter prototype has been built and tested to demonstrate not only the functionality but also the practicality of the new proposal. At the end of the article, the power capability of the new ES system is investigated and compared with previous ES to highlight its features. |
Persistent Identifier | http://hdl.handle.net/10722/293155 |
ISSN | 2023 Impact Factor: 6.6 2023 SCImago Journal Rankings: 3.644 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | LIU, H | - |
dc.contributor.author | Ng, W | - |
dc.contributor.author | Lee, CK | - |
dc.contributor.author | Hui, SYR | - |
dc.date.accessioned | 2020-11-23T08:12:37Z | - |
dc.date.available | 2020-11-23T08:12:37Z | - |
dc.date.issued | 2020 | - |
dc.identifier.citation | IEEE Transactions on Power Electronics, 2020, v. 35 n. 8, p. 8013-8024 | - |
dc.identifier.issn | 0885-8993 | - |
dc.identifier.uri | http://hdl.handle.net/10722/293155 | - |
dc.description.abstract | In this article, a new structure of the electric spring (ES) system using a three-phase inverter is proposed. Noncritical or flexible loads associated with ES can be turned into a smart load. The smart load consumes power adaptively to achieve quick demand response in the future smart grid. Compared to previous ES topologies, the new structure of ES eliminates the battery storage and isolation transformer. The benefit of size and weight reduction results in further improvement on power density of the system. The control strategy is developed and the optimal operating condition for the new ES system is explicitly studied. Power inverter prototype has been built and tested to demonstrate not only the functionality but also the practicality of the new proposal. At the end of the article, the power capability of the new ES system is investigated and compared with previous ES to highlight its features. | - |
dc.language | eng | - |
dc.publisher | Institute of Electrical and Electronics Engineers. The Journal's web site is located at http://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=63 | - |
dc.relation.ispartof | IEEE Transactions on Power Electronics | - |
dc.rights | IEEE Transactions on Power Electronics. Copyright © Institute of Electrical and Electronics Engineers. | - |
dc.rights | ©20xx IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. | - |
dc.subject | Electric spring (ES) | - |
dc.subject | flexible loads | - |
dc.subject | pulsewidth modulation converters | - |
dc.subject | smart grids | - |
dc.title | Integration of Flexible Loads and Electric Spring Using a Three-Phase Inverter | - |
dc.type | Article | - |
dc.identifier.email | Ng, W: waimanng@hku.hk | - |
dc.identifier.email | Lee, CK: cklee@eee.hku.hk | - |
dc.identifier.email | Hui, SYR: ronhui@eee.hku.hk | - |
dc.identifier.authority | Lee, CK=rp01580 | - |
dc.identifier.authority | Hui, SYR=rp01510 | - |
dc.identifier.doi | 10.1109/TPEL.2019.2953603 | - |
dc.identifier.scopus | eid_2-s2.0-85083957185 | - |
dc.identifier.hkuros | 319071 | - |
dc.identifier.volume | 35 | - |
dc.identifier.issue | 8 | - |
dc.identifier.spage | 8013 | - |
dc.identifier.epage | 8024 | - |
dc.identifier.isi | WOS:000530303600028 | - |
dc.publisher.place | United States | - |
dc.identifier.issnl | 0885-8993 | - |