File Download
There are no files associated with this item.
Links for fulltext
(May Require Subscription)
- Publisher Website: 10.1016/j.clinbiochem.2016.02.016
- Scopus: eid_2-s2.0-84970027687
- PMID: 26968104
- WOS: WOS:000377030600005
- Find via
Supplementary
- Citations:
- Appears in Collections:
Article: Plasma miR-124-3p and miR-16 concentrations as prognostic markers in acute stroke
Title | Plasma miR-124-3p and miR-16 concentrations as prognostic markers in acute stroke |
---|---|
Authors | |
Keywords | MicroRNA Stroke Plasma Prognosis |
Issue Date | 2016 |
Citation | Clinical Biochemistry, 2016, v. 49, n. 9, p. 663-668 How to Cite? |
Abstract | © 2016 The Canadian Society of Clinical Chemists. Objectives: This study aimed to investigate plasma concentrations of miR-124-3p and miR-16 as prognostic markers in emergency department patients with acute stroke. Design and methods: Plasma concentrations of miR-124-3p and miR-16 of 84 stroke patients (presenting to the emergency department within 24 h from onset of symptoms) were determined by RT-qPCR. The primary outcome measure was 3-month mortality and the secondary outcome measure was post-stroke modified Rankin Score (mRS). Results: Twelve patients (14.3%) died within 3 months of hospital admission and forty-one (48.8%) patients as achieved a 3-month mRS > 2. Median plasma miR-124-3p concentrations were elevated in patients who died compared to patients who survived (p = 0.0052), and its levels were found to be higher in patients with a 3-month mRS > 2 compared with patients with mRS ≤ 2 (p = 0.0312). Higher plasma miR-16 concentrations were observed in patients who survived than in patients who died (p = 0.0394), while its concentrations were lower in patients achieving mRS > 2 than in patients with mRS ≤ 2 (p = 0.0124). For a subgroup of cases presenting to the emergency department within 6 h from time of symptom onset (n = 36), plasma miR-124-3p concentrations predicted 3-month mortality with an area under the ROC curve of 0.87 (95%CI: 0.72-0.96). Conclusions: Plasma miR-124-3p and miR-16 are molecular markers which could be useful for the early prediction of mortality and mRS. |
Persistent Identifier | http://hdl.handle.net/10722/292944 |
ISSN | 2023 Impact Factor: 2.5 2023 SCImago Journal Rankings: 0.703 |
ISI Accession Number ID |
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Rainer, Timothy Hudson | - |
dc.contributor.author | Leung, Ling Yan | - |
dc.contributor.author | Chan, Cangel Pui Yee | - |
dc.contributor.author | Leung, Yuk Ki | - |
dc.contributor.author | Abrigo, Jill Morales | - |
dc.contributor.author | Wang, Defeng | - |
dc.contributor.author | Graham, Colin A. | - |
dc.date.accessioned | 2020-11-17T14:57:33Z | - |
dc.date.available | 2020-11-17T14:57:33Z | - |
dc.date.issued | 2016 | - |
dc.identifier.citation | Clinical Biochemistry, 2016, v. 49, n. 9, p. 663-668 | - |
dc.identifier.issn | 0009-9120 | - |
dc.identifier.uri | http://hdl.handle.net/10722/292944 | - |
dc.description.abstract | © 2016 The Canadian Society of Clinical Chemists. Objectives: This study aimed to investigate plasma concentrations of miR-124-3p and miR-16 as prognostic markers in emergency department patients with acute stroke. Design and methods: Plasma concentrations of miR-124-3p and miR-16 of 84 stroke patients (presenting to the emergency department within 24 h from onset of symptoms) were determined by RT-qPCR. The primary outcome measure was 3-month mortality and the secondary outcome measure was post-stroke modified Rankin Score (mRS). Results: Twelve patients (14.3%) died within 3 months of hospital admission and forty-one (48.8%) patients as achieved a 3-month mRS > 2. Median plasma miR-124-3p concentrations were elevated in patients who died compared to patients who survived (p = 0.0052), and its levels were found to be higher in patients with a 3-month mRS > 2 compared with patients with mRS ≤ 2 (p = 0.0312). Higher plasma miR-16 concentrations were observed in patients who survived than in patients who died (p = 0.0394), while its concentrations were lower in patients achieving mRS > 2 than in patients with mRS ≤ 2 (p = 0.0124). For a subgroup of cases presenting to the emergency department within 6 h from time of symptom onset (n = 36), plasma miR-124-3p concentrations predicted 3-month mortality with an area under the ROC curve of 0.87 (95%CI: 0.72-0.96). Conclusions: Plasma miR-124-3p and miR-16 are molecular markers which could be useful for the early prediction of mortality and mRS. | - |
dc.language | eng | - |
dc.relation.ispartof | Clinical Biochemistry | - |
dc.subject | MicroRNA | - |
dc.subject | Stroke | - |
dc.subject | Plasma | - |
dc.subject | Prognosis | - |
dc.title | Plasma miR-124-3p and miR-16 concentrations as prognostic markers in acute stroke | - |
dc.type | Article | - |
dc.description.nature | link_to_subscribed_fulltext | - |
dc.identifier.doi | 10.1016/j.clinbiochem.2016.02.016 | - |
dc.identifier.pmid | 26968104 | - |
dc.identifier.scopus | eid_2-s2.0-84970027687 | - |
dc.identifier.volume | 49 | - |
dc.identifier.issue | 9 | - |
dc.identifier.spage | 663 | - |
dc.identifier.epage | 668 | - |
dc.identifier.eissn | 1873-2933 | - |
dc.identifier.isi | WOS:000377030600005 | - |
dc.identifier.issnl | 0009-9120 | - |